CIPDB › China Industry › Instruments & Meters › Medical Diagnosis Equipment
China Bm2000A Sleep Apnea Monitor The Latest Sleep Monitoring Devices1 Products Supplier or Manufacturer.
Medical Diagnosis EquipmentWrist OximeterBluetooth Oximeter
Shanghai Berry Electronic Tech Co., Ltd.
Preview:
Product Description BM2000A Sleep monitoring systemSuitable for sleep hypopnea syndrome monitoringInstructionsBerry Sleep Apnea Screening Monitor has CE0123, ISO13485, NMPA and we can meet most people's measurements of blood oxygen and pulse rate. It can accurately capture pulse signals and has been validated in numerous clinical trials. Major Features1. The product is user-friendly and can be operated with a single button.2. It is compact and lightweight, making it easy to carry.3. The product has low power consumption.4. When the battery voltage is low and may affect normal operation, a low voltage warning indicator will appear on the display.5. It features an automatic shutdown function.6. No routine maintenance or calibration is required.7. A prompt will be issued when the measurement signal exceeds the threshold(If supported).8. It can communicate with smart terminal devices via Bluetooth (If supported).Operation Process1,Download the BerrySmartHealth APP from Google Play and Apple Store.2,Wear the equipment to keep at least 6 hours sleep monitoring.3,Put on the device and wrap foam spO2 sensor around fingertip.4,The collected data is transferred to the mobile phone via bluetooth.5,Display report on phone.6,Reports can be shared.Technical FeaturesDisplay SpO2, PR,PIBattery Type: 3.7v Lithium batteryPulse Rate:Measurement range: 25 - 250bpmAccuracy: ±2bpmSpO2:Measurement range: 0% - 100%Accuracy: ±2% (70% - 100%)Size:57(L)x56(W)x14(D)mmWeight: 34g±1g (Do not contain sensor)Working Voltage: DC 3.4v ~ DC 4.3vFree App: "BerrySmartHealth"Accuracy TestBlood Oxygen Concentration Tes Pulse Rate Test Berry Product Rate VS Reference heart rate ECG Correlation=0.98, P-value< 0.0001 Average reference oximeter Reference Heart Rate(ECG) Effective (SaO2) (ECG) [BPM]Comparison: Reference Pulse OximeterBerry Pulse Oximeter70 ~ 10090 ~ 10080 - < 9067 - < 80RESE≤3% Within the range of 70~100%# pts240798181Error-0.6-1.1-0.90.1PassRoot mean square error1.91.72.02.1 Berry products have passed the accuracy test, blood oxygenconcentration accuracy <2%,510k requirements<3% Analysis Of Clinical Trial ResultsMean Blood OxygenAverage blood oxygen calculation accuracy: 98.51%Diagnosis of hypoxemiaSensitivity: 89.29%Specificity: 77.78%Accuracy:92.59%OSAHS Judgment ResultsSensitivity: 94.17%Specificity: 61.21%Accuracy:89.62%
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...