China, Chinese Fpa, Fpax, Fpar, AC Current Transducers1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Products Details Supplier Manufacturer price list catalog
TransmitterFpaxFparAC Current TransducersPower TransducerCurrent Transmitter
Haiyan Jinhan Import-Export Co., Ltd.
Preview:
Product Description Applied Standards&Rules Measuring and conversion IEC 688 / 1992 - 04 Dielectrical strength IEC 688 2KVac / 1 min. Surge and Impulse test ANSI C37.90 / 1989 IEC 255-3 (1989) 4KV 1.2 x 50 us Models FPA 1 unit of avg. to rms conversion FPAX 3 unit of avg. to rms conversion FPAR Ture rms conversion Order form Input &Output parametersPy : DC24 / 48 / 125 V ± 20% or other range under specifiedNote:External power mode suitably for all output typesInternal power mode, only suitably for 0-1mA / 0-20mA / 0-1V / 0-5V / 0-10V output SpecificationAccuracy ( 23±3°C ) 0.2% RO .......... FPA, FPAX, FPV, FPVX 0.2% RO .......... FPAR, FPVR Maximum output load DC current mode : maximum 10V drop DC voltage mode : maximum 5mA drive Dielectric strength AC 2KV 1 minute between terminals; AC 2.6KV 1 minute / terminals to caseSurge and impulse test ANSI C37.90 / 1989, IEC 255-3 (1989) 4 KV 1.2 x 50 usMaximum input over Current related input Voltage related input 1A / 5A 10A 4 x rated / continuous 2 x rated / continuous 1.5 x rated / continuous 10 x rated / 10 seconds 25 x rated / 1 second 2 x rated / 10 seconds 50 x rated / 1 second 50 x rated / 0.5 second 80 x rated / 0.5 second Input burden Current less 0.2 VA; voltage less 0.1 VA Response time & ripple ?400 ms for step change 0-99% ripple less 0.5% ro peak to peakFrequency 45 ~ 400 Hz Stability Temperature range ( 20 to 30°C ) long term stability / year Maximum 60 ppm / °C less 0.2% draft / year typicallyStorage condition Temperature range -25 to 70°C, RH 20 to 95% non condensedOperating condition Temperature range -20 to 65°C, RH 0 to 99% non condensedMagnetic field effect < 0.01% under 100 ampere turns at 1M center Power dissipation Maximum 3.5 VA for FPA / FPAR / FPV / FPVR; 8 VA for FPAX / FPVX6.Terminal ConnectionModel and Ordering FPA-An-Fn-Pn-OnExample: 1. FPA-A2-F1-P2-03Input:5AAuxiliary Frequency:50HzPower:AC 220VOutput:4-20mAIf you have any questions about this,welcome to contact us.We are all at service. Technical Specification Reference Standard GB/T 13850-1998(IEC688-1992) Accuracy Long Term stability ≤±0.2%/year.No accumulation errorTemperature influence≤ 100ppm/oCResponse Time <400ms Output Ripple<0.4%(peak-peak value) Input burdenCurrent less 0.2VA;voltage less 0.1VA Frequency Nominal frequency ±10% Maximum output loadCurrent output Max10V pressure drop Auxiliary power Ratedvoltage80%-120%,rated current 90%-110% Auxiliary load effect <± 0.1% Allow excessive input Current 3rate continuous 10rate 30 secs voltageMax 2ratecontinuous Dielectric strengthInput /output /power/between the crust 2KV AC 1 minIEC866 Impact testANSIC37.90a/1973,IEC255-4 (5kV1.2/50us PulsedVoltage) Calibration amplitudeFull scale least±3%,zero least±1% Magnetic field effect0.4KA/m magnetic field strength change <0.05% Operating condition Temperature -10~55oC relative humidity≤95%RHnoncondensing Storage condition Temperature -40~70oC relative humidity ≤95% RHnoncondensing Haiyan Jinhan Electronic Technology CO.,LTDFP Series Electric Quantity TransmitterFPAFPARFPATFPAX FPVFPVRFPVTFPVX FPWFPW201FPW301FPWTFPWT201 FPKFPK201FPK301FPKTFPKT201 FPWKFPWK201FPWK301FPWKAFPWKA201FPWKA301FPWHFPWH201FPWH301FPKHFPKH201FPKH301FPWWHFPWWH201FPWWH301FPKKHFPKKH201FPKKH301FPFFPFTFPPFFPPFTFPHFPSFPD-1FPD-2FPDH-1FPDH-2FPT-1FPT-2We can provide the product model and specifications: ProductModel No.AC current transducerJD194-BS4I-NAC voltage transducerJD194-BS4U-NAC current transducerJD194-BS4IDC current transducerJD194-BS5IAC voltage transducerJD194-BS4UDC voltage transducerJD194-BS5UPower transmitterJD194-BS4PPower transmitterJD194-BS4QPower factor transducerJD194-BS4H7Frequency transmitterJD194-BS4F7Integrated transmitterJD194-BS4Z6Integrated transmitterJD194-BS4Z8Integrated transmitterJD194-BS4Z-STemperature transmitterBS6TResistance transducerBS6RIntelligent signal conditionerBS6MAC current transducerRPAAC voltage transducerRPVAC current transducerRPATAC voltage transducerRPVTAC current transducerRPAXAC voltage transducerRPVXPower transmitterRPWPower transmitterRPKPower transmitterRPWKPower factor transducerRPPFFrequency transmitterRPFFrequency transmitterRPFTAC current transducerCPAAC voltage transducerCPVAC current transducerCPATAC voltage transducerCPVTAC current transducerCPAXAC voltage transducerCPVXPower transmitterCPWPower transmitterCPKPower transmitterCPWKPower factor transducerCPPFFrequency transmitterCPFFrequency transmitterCPFTPower transmitterFPWPower transmitterFPKPower transmitterFPWTPower transmitterFPKTPower transmitterFPWKDC transducerFPD-1HDC transducerFPD-2HDC transducerFPDH-1HDC transducerFPDH-2HAC current transducerFPAAC voltage transducerFPVAC current transducerFPA2AC voltage transducerFPV2AC current transducerFPARAC voltage transducerFPVRAC current transducerFPATAC voltage transducerFPVTAC current transducerFPAXAC voltage transducerFPVXAC current transducerFPAX2AC voltage transducerFPVX2AC current transducerGPAAC voltage transducerGPVAC current transducerGPA2AC voltage transducerGPV2AC current transducerEPAAC voltage transducerEPVAC current transducerGPATAC voltage transducerGPVTAC current transducerGPAXAC voltage transducerGPVXAC current transducerGPAX2AC voltage transducerGPVX2AC current transducerGPASAC voltage transducerGPVSGenerator negative sequence current meterFPFX-100Temperature transmitterFT3Temperature transmitterFT2Temperature transmitterFT2-CTemperature transmitterGPTTemperature transmitterEPTShift transmitterFPBShare This Story, Choose Your Platform! Detailed Photos
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...