IPDB › China Industry › Industrial Equipment & Components › Air Clean Equipment
Dynamic Vhp Pass Box Aseptic Transfer Window Sterilization Rate 6LG for Cleanroom2
Air Clean Equipment, Pass Box, Vaporized Hydrogen Peroxide Pass Box, Negative Pressure Pass Box
Suzhou Pharma Machinery Co., Ltd.
Preview:
Product Description VHPB series sterilization transfer cabin :The VHPB series sterilization transfer cabin is a special sterilization equipment that can provide absolute biologicaldecontamination on the surface of the article when transferring articles between different functions. It is equipped with a dedicated hydrogen peroxide VHP generator, a sterile air supply system, an electromagnetic door interlocking system, a closed system, a residue removal system after sterilization, a dedicated HMI (human machine interface) and a sterilizing medium delivery system. It is widely used for surface sterilization at room temperature in places such as pharmacy, medical treatment, sanitation, biological experiment, etc.FeaturesEfficient sterilizationUsing VHP technology for sterilization can effectively eliminate bacteria, viruses, and other microorganisms, ensuring that items remain sterile during transmission.Double door interlocking designEquipped with a dual door interlock system, ensuring that only one door can be opened at any time to prevent cross contamination.Durable and sturdyMade of high-quality stainless steel material, corrosion-resistant, easy to clean, suitable for high cleanliness environments.User-friendly designEquipped with transparent observation windows, it is convenient for operators to observe the internal situation in real time. Built in UV lamp and hydrogen peroxide steam generator ensure efficient sterilization.Easy to operateBy adopting advanced control systems, users can easily operate and monitor the sterilization process in real-time through a touch screen.Efficient sterilization: The VHP transfer window uses gaseous hydrogen peroxide as a sterilization agent, which has a broad spectrum sterilization effect, and can effectively kill bacteria, viruses, spores and other microorganisms, with a sterilization rate of more than 99.9999%.Intelligent control: The equipment is equipped with advanced control system, which supports two modes of operation: automatic and manual. Users can set sterilization time, temperature and other parameters according to actual needs to achieve accurate control. At the same time, the system has fault alarm and self-protection functions to ensure the stable operation of the equipment.Double-door interlock: The VHP transfer window uses a double-door interlock design to ensure that after one door is completely closed and locked, the other door can be opened, effectively preventing cross-contamination of the internal and external environment.Fast recovery: After sterilization, the residual hydrogen peroxide gas inside the equipment can be quickly discharged through the ventilation system to ensure that the material can be taken out and used in a short time, improving the work efficiency.Excellent material: The main body of the equipment is made of high-quality stainless steel material, with corrosion resistance, easy to clean and other characteristics, in line with GMP and ISO standards.Product NameVHP Pass Boxmaterial qualityStainless steel SUS 304/SUS 316Clean GradeClass AWindow materialTempered glass/acrylicOperation doorDouble door interlockSealing methodAirtight sealing stripsurface treatmentPolishing/Drawingcontrol systemPLC controlSterilizing agentHydrogen Peroxide (VHP)sterilization time30 minutes -120 minutes (adjustable)Sterilization effect99.9999% kill rate (6-log)Filtering systemHEPA filter (≥ 99.99% @ 0.3 μ m)Exhaust systemBuilt in fansterilization cycleAutomatic loopsafety protectionOverpressure protection, leakage detection, automatic alarm systemsource220V/50Hzpower500Wdisplay screenLCD touch screenOperation interfaceMulti language supportdata recordUSB data exportUsage environmentTemperature: 10-35 oC, humidity: ≤ 85%application areaPharmaceuticals, laboratories, electronics, semiconductors, food, etc Instructions for use:1. PreprocessingPlace the item to be delivered into the VHP Pass Box, ensuring that the surface of the item is dry and clean.2. Sterilization processStart the VHP sterilization system and select the sterilization time as needed. The system will automatically generate and release hydrogen peroxide vapor for sterilization.3. TransmissionAfter sterilization is completed, the internal system will notify the operator to release the double door interlock. The operator can open the door on one side of the clean area to remove sterilized items.Maintenance and upkeep:1. Regular cleaningAfter each use, the interior of the VHP Pass Box should be cleaned to prevent residues from affecting the sterilization effect.2. Check the sealingRegularly inspect the sealing strip and interlock device of the door to ensure their normal function.3. Replace consumablesRegularly replace the hydrogen peroxide liquid and UV lamp according to the equipment manual to ensure optimal performance of the equipment.Notes:1. Safety protectionDuring operation and maintenance, protective gloves and masks should be worn to avoid direct contact with hydrogen peroxide.2. Environmental requirementsThe equipment should be installed in a clean, dry, and well ventilated environment, avoiding direct sunlight and high temperature and humidity.
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.