50Hz 10.5kv 1000kw Cummins Power Open/Silent Natural Gas Generator Set1
Power Generating Sets, Natural Gas Genset, Generator Set
Changsha U1 Technology Co., LTD
Preview:
Product Description Genset working condition:Acceptable ambient temperature: -25oC~+45oCRelative humidity:<90%, 20oC, Altitude: ≤500mNormal working conditions:Genset can run at rated power on the conditions:Atmospheric Pressure: 100kPa, Ambient Temp: 20oC, Relative Humidity: 30%.Applied gas: Natural gas.Acceptable fuel gas pressure: 5~20kPaCH4 content ≥85%Gas doesn't include free water or free materials (the size of impurities should be less than 5μm.)Gas Genset SpecificationGas generator dataGenset modelU1GC1000-GContinuous power (kW/kVA)1000/1250Connection type3 phases 4 wiresPower factor0.8 laggingVoltage10.5kVFrequency (Hz)50Gas genset electrical efficiency38%Gas genset thermal efficiency45%Total efficiency83%Gas consumption at full load9.47MJ/kWhLubricant oil consumption0.36g/kWhVoltage Stabilized regulation≤±1.5%Voltage Instantaneous regulation≤±20%Voltage Recovery time (s)≤1Voltage Fluctuation ratio≤1%Voltage Wave aberration ratio≤5%Frequency Stabilized regulation≤1%(adjustable)Frequency Instantaneous regulation-10%~12%Frequency Fluctuation ratio≤1%Net weight(kg)13,980Containerized type dimension(mm)12.192×2.438×2.896 UK Deepsea controller DSE8620 MKII(Or ComAp controller IG500-G2) The DSE8620 MKII represents the latest in complex load sharing & synchronizing control technology. Designed to synchronize a single genset with a mains (utility) supply, the DSE8620 MKII control module is packed with multiple features and benefits that are unrivalled across the generator control industry.The controller also has the option to be configured for use as a DSE8610 MKII Auto Start Load Sharing & Synchronizing Control Module. When converted for use as a DSE8610 MKII the unit provides generator to generator load share functionality. Synchronization/Parallel PanelModelU1S1000Capacity2000AAir circuit breaker brandCHINTControllerDSE8620 MKII/ComAp IG500G2Features:Automatically synchronize gas gensetsAutomatically unload the gen-setProgrammed start and stop gen-setGen-set monitoring and protectingsynchronize gensets with national grid(mains)/Multiple gensets paralleling.40ft high containerized canopyFeatures:ISO 40ft high container with CCS certificate.2. Top-quality of paint to guarantee good protection under hard weather.3. Weather-proof, dust-proof, sound-proof, suitable for rigorous environment.4. All canopy parts are designed with modular principles and canopy materials use strong steel board.5. All metal canopy parts are painted by electrostatic polyester powder paint.6. Efficient air intake and exhaust system to ensure stable output.7. Scientific design and advanced techniques to reduce noise level to 75-85db(A), materials and its covers further ensure sound-absorbing efficiency and protection function.8. Locks of canopy design are more convenient for the operation and maintenance also ensure the safety of gen-set more.9. Lifting-eye and forklift design are easy for transportation.10. Emergency stop push button outside of canopy.11. Well-formed and compact design, the big built-in muffler makes the noise lower. Automatic Oil filling, KENCO brandFeatures:Automatically add lubricant oil for gas gen-set Horizontal remote radiatorStandby remote radiator will run to cool engine when:1. The heat recovery system is not working due to maintenance/repair.2. Customer does not need hot water, but need gas genset to run to produce electricity only.3. Engine coolant temperature is too high.Heat recovery system(OPTIONAL)MaterialStainless steelHeat exchangersJacket water plate heat exchanger and exhaust heat exchangerElectrical efficiency38% at 1000kWelThermal efficiency45%Thermal power1184kWthInlet water temperature60oCOutlet water temperature85oCHot water flow rate11.3L/sFeatures:Increase the total efficiency.Hot water can be for the life and industrial useDelivery time:Within 40 days after receiving deposit.PaymentT/T, 30% paid as deposit before production, 70% paid as balance paid before the shipment.WarrantyWe shall provide a warranty of 6000 running hours or 12 months from B/L date (whichever comes first), covering all manufacturing defects. We replace damaged parts caused by manufacturing faults or defected parts/materials, but excluding consumables parts and damageable parts due to customer's incorrect man-made operation. After expiration, we still provide technical and spare parts support with cost for maintenance.Training and commissioning serviceFree training can be provided in the factory by our gas power generation engineers. The training focuses on gas genset application, operation, and maintenance. We can also send engineers to Customer's genset location site to do gas genset commissioning. Scope of Supply Brand new Cummins gas engine. Brand new brushless Leroy Somer alternator. Genset automatic controller, UK Deepsea DSE8620 MKII/ComAP controller. 40ft high containerized soundproof canopy. Synchronization panel with CHINT motorized circuit breaker. Gas train valves (Germany DUNGS gas regulator, solenoid valve, flame arrestor, ball valve). Automatic oil filling system. Oil heater and coolant heater. Remote radiator. Accessories list for each engine:ItemsQuantitySilencers2Elbows1 setScrews and flanges1setAsbestos Pad1 setAnti-rust liquid1Genset starting free maintenance batteries, Battery charger, Battery cables1 setStandard toolbox1Documents list:Gen-set operation manual, Genset maintenance manual1 setEngine part book1Alternator manuals, maintenance manuals, parts book1 setGenset installation drawings electrical system drawings.1 setComAp IG-NT Controller instruction1Engine Certificate, Alternator Certificate, Gen-set Certificate1Gen-set Testing Reports1Details
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.