IPDB › China Industry › Industrial Equipment & Components › Power & Generating Sets
Industrial Generator 500/1000/1500/1800/2000/2250/2500kVA Cummins Perkins Mitsubishi Sme Baudouin Yuchai Weichai Engine Standby Silent Diesel Power Generators1
Power Generating Sets, Perkins Generator, Diesel Generator
MECCA POWER CO., LTD.
Preview:
Product Description Mecca Power, as part of a Global Power Supplier initiative, provides a professional solution for the design, application and after-sales support of generators.With more than 10 years of experience in manufacturing and exporting energy products, the Mecca team will advise you on product choices. Generator IntroductionSilent/Open/Containerized Type diesel generator with Perkins Engine for construction/factory/building/power plant-Power by Doosan/Yanmar/Perkins engine-With Stamford / Leroy Somer / Marathon alternator-With ABB MCCB & Electronic Components-Electric start with battery-10 hours Lasting Base Integrated fuel Tank-Strictly comply with ISO9001/CE -24*365 hours global after-sale services-Option:ATS, Deepsea / ComAp controller-All sets COO CertificateVIEW MORE PRODUCTS CLIK HERE...SpecificationPowered by Perkins 50HZ 220-440 V 10-2500KVA ModelLTPPRPEngineKVA / KW KVA/KW ModelOriginMC10P108 97403A-11G1CN/UKMC10P108 97403D-11GCNMC14P1411 1310403A-15G1CNMC14P1411 1310403D-15GCNMC16P1613 1512403A-15G2CNMC23P2318 2016404A-22G1CNMC23P2318 2016404D-22GCNMC30P30242822404D-22TGCNMC33P3326 30241103A-33GUK/INMC50P5040 45361103A-33TG1UK/INMC66P6653 60481103A-33TG2UK/INMC72P7257 65521104A-44TG1CNMC88P8870 80641104C-44TAG1CNMC88P8870 80641104A-44TG2CNMC113P11390 100801104C-44TAG2CNMC150P150120 1351081106A-70TG1CNMC165P165132 1501201106A-70TAG2CNMC200P200160 1801441106A-70TAG3CNMC220P220176 2001601106A-70TAG4CNMC220P220176 2001601206A-E70TTAG1UKMC250P250200 2251801506A-E88TAG2USAMC250P250200 2251801206A-E70TTAG2UKMC275P275220 2502001206A-E70TTAG3UKMC339P339271 3062451706A-E93TAG1USAMC383P383306 3482781706A-E93TAG2USAMC275P275220 2502001506A-E88TAG3USAMC330P330264 3002401506A-E88TAG5USAMC400P400320 3502802206C-E13TAG2USAMC450P450360 4003202206C-E13TAG3USAMC500P500400 4503602506C-E15TAG1USAMC550P550440 5004002506C-E15TAG2USAMC660P660528 6004802806C-E18TAG1AUSAMC715P715572 6505202806A-E18TAG2USAMC825P825660 7506004006-23TAG2AUK/INMC880P880704 8006404006-23TAG3AUK/INMC1000P1000800 9007204008TAG1AUK/INMC1100P1100880 10008004008TAG2AUK/INMC1100P1100880 10008004008TAG2UK/INMC1250P12501000 11259004008-30TAG3UK/INMC1375P13751100 125010004012-46TWG2AUK/INMC1500P15001200 135010804012-46TWG3AUK/INMC1650P16501320 150012004012-46TAG2AUK/INMC1875P18751500 168813504012-46TAG3AUK/INMC2000P20001600 185014804016TAG1AUK/INMC2250P22501800 200016004016TAG2AUK/INMC2500P25002000 225018004016-61TRG3UK/INMORE SEPC. CONTACT US...Genset WorkshopFAQ1.Q: What is your MOQ of this item?A:1 Set2.Q: What are your payment terms?A:30% TT as deposit,70% TT before Shipment or 100% LC at sight3.Q:What's the warranty time of diesel generators?A:Global Warranty: 12months after delivery or 1000 running hours, whichever come first.4.Q:Can you accept the customized products?A:Yes, of course.We accept your specific order if you can provide us your special requirements or special samples5.Q:What's the delivery time ?A:20 to 35 days after receiving your payment in advance.6.Q:Do you offer OEM service?A: Yes7.Q:What is the power range do you have?A:Mecca Power assemble genset from 2 to 4000kva8.Q:What's your special compare to other manufacturer?A:We can delivery genset 1000units/month as engine and alternator OEM and Strategic partners. Especially for big quantity and big power projects, we support not only by solutions and tender documents, but also by fast delivery time and good price. Item Service Option Delivery Time 1EngineDoosan, Mtu, Mitsubishi, SME, Volvo, Deutz, Yanmar, Faw, YangDong, Aoling, Yuchai, Lovol, Wandi, ect.Marine and industry use Diesel, gas2-45days2AlternatorStamford, Leroysomer, Meccalte, Marathon and customer requested alternatorsMedium and high voltage, Marine and industry use High IP GradeCT Drop kits, PMG, AVR2-15 days3RadiatorFast, Beworld brandOriginal Radiator come with engineLocal made radiator with authorization by engine supplier2-7days4CanopiesPowder coated and form mounted canopy,completely break down with hings,locks, raincap,bolts,screws, etc.Exhaust pipe and flanges Standard silent type canopy package Denyo type canopy package Rental type canopy package Telecom type canopy package Super silent type canopy package Containerized type canopy package Customerized type canopy package10days5Base frameStandard base or simple iron baseAnti-Vibration mountingsWith/without tank, base tank volume no limitedFuel gauges and high pressure fuel pipes3days6Control systemController: ComAp, DeepSea, Datacom, SmartGen etc.Breaker:Delixi,ABB, Chint, etc.Battery switch, battery charger, emergency stop botton, indicator, meters, CT and all wiring and harness.Batteries and cablesSpeed & lub oil & water temp sensors,A package of standard parts for assembly3days7Exhaust SystemIndustrial and residential silencerFlexible connects and elbow3days8Others Special demands -----------------------------------------------------------------------------------------------MAITAINENCE-------------------------------------------------------------------------------------------General Troubleshooting This section lists the generating set for some common fault, the reasons for the failure and determines the method of fault. General operators can determine their own fault and note, maintenance it according to the brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation. Please remember the following suggestions before repairing: - Make sure that study the failure carefully before any operation. - Repair with the easiest way and most commonly used method. - Find the exact causes of failure and completely solve the fault. 1. Generator Sets Description of this section is for reference only. If the following failure occurs please contact the repairing agents. (Some models of control panel installed only parts of the following warning indicator light)IconIndicator LightReasonFault AnalysisLow oil pressurealarmLow oil pressurealarmWhen oil pressure does notreduce normally, the light is on.-General because of a lack of oil or lubricationsystem failure caused by (refueling or replacingthe oil filter)-When occurs this fault should automaticallyshutdown generator sets immediately.High watertemperaturealarmHigh watertemperaturealarmWhen the water temperaturehas risen to a level higher thanor equal to the sensor setting,the light is on.-General because of a lack of water or oilshortage, or overload.-When occurs this fault should automaticallyshutdown generator sets immediately.Low fuel levelalarmLow fuel levelalarmWhen a fuel level has beendetected by the sensor fitted tothe daily tank, the light is on.-General because of a lack of water or oilshortage, or overload.-When occurs this fault should automaticallyshutdown generator sets immediately.Battery chargerfault alarmBattery chargerfault alarmIf the charging system has fault,when engine running, the light isoff.-Battery charging system fault caused.-The light is on at the initial start, when thecharger reaches a certain speed, the light is off.-This failure will not lead to automatic shutdowngenerating units.Crank failurealarmCrank failurealarmWhen the generator set failedthree times (or six times) in arow starting, the light is on.-Oil supply system or re-start the system failurecaused.Overload orbreaker trippingalarmOverload orbreaker trippingalarmWhen overloading or Shortcircuit, the light is on. Trippingcircuit breakers cause generatorset load out.-In this fault, it need to load or unload some partsto eliminate short-circuit, and then re-close thecircuit breaker.Introduction of Maintenance grade(Interval) for the generator set A Level Maintenance Interval (Daily Maintenance)1. Check Daily Report of Genset .2. Check fuel level and coolant level. 3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or other damage.4. Check the Air filter. The air filter should be replaced when necessary .5. Release fuel tank and fuel filter's water and sediment.6. Check the water cooling filter.7. Check starting battery and electrolyte, add electrolyte when necessary. 8. Check the starter, check noisy defect.9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.B Level Maintenance Interval (Less than 400 hours)1. Repeatedly check A Level Daily Maintenance steps.2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice and real fact. 3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF Grade of American Petroleum Institute.4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or it can be replaced. The replacement must be according to the environment and real fact.5. Replace the cooling system and add coolant concentration.6. Clean the crankshaft and inlet, outlet air- filter net. C Level Maintenance Interval (2000-3000 hours), Please do as follows:1. Repeatedly check A and B Level Daily Maintenance steps.2. Remove the tap of valve, clean and wash oil dirt and sludge.3. Fasten snails from each part (including running parts and fixed parts)4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.6. Check and adjust valve clearance.7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; clean and wash water tank radiator fins, then check the using capability of thermostat.Current Repair (D Level Maintenance)(3000-4000 hours)1. Check valve, valve seat and other wearing, repair or change it when necessary.2. Check P pump, quality of injection, repair and adjust it when necessary.3. Check and adjust connecting rod and fastening twisting torque.4. Check and adjust valve clearance.5. Check the trip of injector.6. Check and adjust tension of fan and generating belt.7. Clean and wash accumulation of carbon in inlet pipes.8. Clean and wash the core of air cooler.9. Clean and wash the whole oil lubrication system.10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.Medium Repair (6000-8000 hours)1. Including the items of minor repair.2. Disassemble generator(except crankshaft)3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.4. Check fuel supplying system, adjust oil pump and injector.5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.Overhaul (9000-15000hours)1. Including the items of intermediate repair.2. Disassemble all the parts in the generator.3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake and exhaust valve, a whole set of tools for generator repair 4. Adjust oil pump, injector and replace pump core, injector5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.