IPDB › China Industry › Industrial Equipment & Components › Pump & Vacuum Equipment
Good Quality Usun Model: Gbt15/40-Ol 200-300 Bar Double Stage Oxygen Gas Transfe Boosterr Pump for Cylinder Refilling1
Pump Vacuum Equipment, Oxygen Gas Booster Pump, Oxygen Gas Booster
Dong Guan Usun Fluid Control Equipment Co., Ltd.
Preview:
Product Description USUN Model :GBT 15/40-OL 160MM driven double stage oxygen gas transfer pump for refilling gas cylinder Usun air driven gas booster pumps are ratio devices that utilize low pressure compressed air driving a larger diameter piston (area x pressure) which is linearly connected to a smaller hydraulic piston/plunger. Using this ratio principal, a higher hydraulic pressure can be generated. Usun Pump model numbers reflect the pumps nominal pressure ratio, while the technical data indicates exact ratios. The outlet stall pressure is easy to set by adjusting the air drive pressure through a simple air pressure regulator. By multiplying the pressure ratio by the available shop air pressure, the nominal gas pressure can be calculated. Example ( Pump Model: GBT15/40 Gas booster pump)Air drive piston area ( 160mm ?)Hydraulic plunger area ( 25mm ?)Actual ratio = 40:1 1. AIR DRIVE SECTIONThe air drive section consists of a light weight piston complete with seals running inside an aluminum barrel. The diameter of the air piston is 160mm. When compressed air is supplied to the pump the air pushes the air piston down on a compression stroke (forces as out of the gas end). Under the control of pilot pins (poppet valve) triggered at each end of the stroke 2. GAS DRIVEN SECTIONThe gas section of a USUN air driven gas booster consisit of 4 main pieces ,the gas barrel ,the piston the check valves and the main high pressure seals . The gaspiston is directly linked to the air piston and it is housedinside the gas barrel and its movements up and down creates the gas flow into and out of the booster through the check valves . The check valves are psring loaded and on the suction stroke .the inlet check valve opens to the maximum allowing gas into the gas barrel and on the compression stroke the inlet check valve closes the discharge check valve opens forcing the pumped gas into the process .The main high pressure seals is located on the gas piston and they seal agaist the gas barrel during operation . and the maximum pressures of the pump ,however the standard PTFE seals are suitable for both the vast majority of gases encountered . Other materials of construction can be supplied to meet more aggresive services .The standard serials of booster are not suitable for underground coal mine applications . USUN DO Manufacture models of air driven gas boosters that are not suitable for undergroundcoal mine applications .USUN Air driven gas boosters cycle automatically as the outlet pressure increass the resistance also increases and the cycle rate decreases until the pump stops automatically when the out put pressure forces are equal .This is refered to as the stall condition . The pump will restart with a slight drop in the outllet pressure or an increase in the air driven pressure Booster performance can be affected by a number of conditions , such as freezing of the exhaust muffler or pilot valves ( Which is caused by moisture in air lines ),inadequate inlet air line sizes and dirty filers .When operating the boosters on a contunuous basis ,we recommend you use a maximum cycle rate of 50-60 cycles per minute . This will both increase service intervals and assist in preventing ice forming at the exhaust . An air supply dryer will also assist in reducing icing up . USUN Gas boosters have a 120mm stroke thus reducing cycle rates at any given flow and pressure as compared with most other brands . This lower repsective cycle rate res ults in a reduction in freeze-up condition . To abtain best overall performance ,do not reduce the indicated port size and consultUSUN for flow conditions not shown in charts Model selection for gas booster It is very important to remember that the performance of any air driven device is very dependent on the air supply conditions .Restrictions in the air supply can be caused by using a too small air compressor or airlines .The FLOW CHARTS SHOWN in the technical data sheet are based on good conditions . so please do not "design to the line " allow for losses and inefficiencies The next question is wheather you want the booster to stall when an outlet pressure is reached If so ,a simple airline pressure regulator will suffice ,but remember the flow drops off dramatically as the booster reaches a stall condition . If you require flow at a particular pressure ,then you need read the flow cahrts carefully and conservatively If you need the pump to stop at a certain pressure ,prior to stall ,then an air pilor switches needs to be installed . Key features Realiable ,Easy to Maintain ,compact and robust2. No heat,flame or spark risk3. Infinitely variable cycling speed and output4. Air driven Models do not require electrical connection ,easy to apply automatic controls5. No limit or adverse affect to contineous stop/start applications6.Seals system designed for long working life,No airline lubricated required7.Built-in coupling system (Most models) and suitable for most gases boosting Main technical data Typical technical data for double stage air driven gas booster pump ModelPiston rod diameterPressure ratioMinimum inlet pressure PI(Bar)Maximum inlet pressure PI (PO )Maximum Outlet pressure PO(Bar)Outlet pressure formula POInlet port sizeOutlet porst size Maximum Flow rate L/min= 7 BarGBT7/1563/4015:13.41512415PA+2PINPT3/8''NPT3/8''215@PI=7GBT7/3063/2832:13.41520432PA+3PINPT3/8''NPT1/4''118@PI=7GBT15/3040/2832:174020432PA+2PINPT3/8''NPT1/4''150@PI=10GBT15/40-OL40/2540:174533040PA+ 2PINPT3/8''NPT1/4''125@PI=10GBT15/6040/2060:174549860PA+4PINPT3/8'NPT1/4''92@pi=10GBT30/6028/2060:1304549860PA+2PINPT3/8''NPT1/4''245@PI= 40GBT30/10028/16100:13070830100PA+ 3PINPT1/4''NPT1/4''192 @pi=40 Remark 1) Maxium outlet pressure are at an air driven pressure of 8 bar or 116 PSI ,for long life usingof such pump ,we suggest that air driven pressure should be not more than 8 Bar .Typical application of such double stage air driven gas booster pump Factory pictures
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.