IPDB › China Industry › Industrial Equipment & Components › Power & Generating Sets
Containerized Generator 1000/1500/1800/2000/2200/2500/3000/3750 Kw kVA Powered by Cummins/Perkins/Mtu/Yuchai/Mitsubishi/Sme/Baudouin Container Diesel Generators1
Power Generating Sets, Mtu Generator, 2000kw Generator
MECCA POWER CO., LTD.
Preview:
Product Description Mecca Power, as part of a Global Power Supplier initiative, provides a professional solution for the design, application and after-sales support of generators.Strongly focused on innovation and the inherent flexibility of product design, Mecca Power has been successful in global markets with a broad and diverse range of genset power products that can operate autonomously or independently. parallel, on-site or remotely controlled.With more than 10 years of experience in manufacturing and exporting energy products, the Mecca team will advise you on product choices. Product DescriptionSpecificationPowered by MTU 50HZ 400/230 V 500-3300KVA ModelLTPPRPEngineFuel Cons.Cyl.Disp.Gov.KVA / KW KVA/KW ModelOriginL/H(100%)LMC500M500400 450360 10V1600G10FDE101.310V17.5ADECMC550M550440 500400 10V1600G20FDE110.910V17.5ADECMC660M660528 600480 12V1600G10FDE131.712V21ADECMC725M725580 660528 12V1600G20FDE144.912V21ADECMC880M880704 800640 12V2000G65CN184.012V23.9ADECMC1000M1000800 900720 16V2000G25CN210.016V31.8ADECMC1100M1100880 1000800 16V2000G65CN230.816V31.8ADECMC1250M12501000 1125900 18V2000G65CN264.516V31.8ADECMC1375M13751100 12501000 18V2000G26FCN261.118V35.8ADECMC1500M15001200 13501080 12V4000G23RDE307.612V57.2ADECMC1650M16501320 15001200 12V4000G23DE351.512V57.2ADECMC1800M18001440 16251300 12V4000G23DE351.512V57.2ADECMC2000M20001600 18121450 12V4000G63DE398.212V57.2ADECMC2250M22501800 20501640 16V4000G23DE452.116V76.3ADECMC2500M25002000 22501800 16V4000G63DE491.616V76.3ADECMC2750M27502200 25002000 20V4000G23DE561.820V95.4ADECMC3000M30002400 27502200 20V4000G63DE611.620V95.4ADECMC3300M33002640 30002400 20V4000G63LDE651.220V95.4ADECAlternator Data? Operate either 50Hz or 60Hz.?Stator grease insulation covered? Standard enclosure IP23, but IP44, IP55 for option?Rotator and excitation high polymer? Insulation class H. ? Resist the corruption oil and acid? Shunt excitataion systems.?Rotator balance is in accordance with BS5625 ? AREP or PMG system for options. standard 12.5? Automatic voltage regulator?High-quality lubrication sealed long-time bearing? Single bearing alternator?Rotator silicon steel close tightStandard Accessories*Auto Control Panel*Starting Motor*Main Ciruit Breaker*Exhaust silencer*Fuel tank*Starting battery*Base Frame*Float battery charger*Filter *FlangeView more products click here...Genset WorkshopFAQPayment Terms:By telegraphic transfer: 30% deposit on signing of sales contract; and balance 70% before dispatch. Delivery:Approximately 2-4 weeks upon order confirmation.Service Guarantee:Before Service: According to the clients' requirement and actual situation, we will furnish the technology consultation and kinds of information. After Service: Guarantee for one year or 1200 running hours (accord to whichever reach first) from installed date.During the guarantee period, we will provide the free easy-damaged spare-parts for problems caused by our quality of production or raw material, except the damageable spare parts of diesel engine caused by customer's incorrect man-made operation. After checking, our company provides cost spare-parts maintenance for gensets . Beside genset one-stop purchasing service to world-wide customers,CKD and SKD packing service are also available according to unique request.CKD:Complete Knock Down GeneratorGenerator completely knocked down into parts without assembling. All items from following are seperately packed without connection. SKD:Semi Knock Down GeneratorPartially assembled generator. Part of the following items you choose will be assembled. Advantage:Prompt deliveryReduced tax to win more competitionLower transportation fees to save costLocalized production to win more tenders. Increased production to offer more job opportunity for the governmentItem Service Option Delivery Time 1EngineDoosan, Mtu, Mitsubishi, SME, Volvo, Deutz, Yanmar, Faw, YangDong, Aoling, Yuchai, Lovol, Wandi, ect.Marine and industry use Diesel, gas2-45days2AlternatorStamford, Leroysomer, Meccalte, Marathon and customer requested alternatorsMedium and high voltage, Marine and industry use High IP GradeCT Drop kits, PMG, AVR2-15 days3RadiatorFast, Beworld brandOriginal Radiator come with engineLocal made radiator with authorization by engine supplier2-7days4CanopiesPowder coated and form mounted canopy,completely break down with hings,locks, raincap,bolts,screws, etc.Exhaust pipe and flanges Standard silent type canopy package Denyo type canopy package Rental type canopy package Telecom type canopy package Super silent type canopy package Containerized type canopy package Customerized type canopy package10days5Base frameStandard base or simple iron baseAnti-Vibration mountingsWith/without tank, base tank volume no limitedFuel gauges and high pressure fuel pipes3days6Control systemController: ComAp, DeepSea, Datacom, SmartGen etc.Breaker:Delixi,ABB, Chint, etc.Battery switch, battery charger, emergency stop botton, indicator, meters, CT and all wiring and harness.Batteries and cablesSpeed & lub oil & water temp sensors,A package of standard parts for assembly3days7Exhaust SystemIndustrial and residential silencerFlexible connects and elbow3days8Others Special demands -----------------------------------------------------------------------------------------------MAITAINENCE---------------------------------------------------------------------------------------------General Troubleshooting This section lists the generating set for some common fault, the reasons for the failure and determines the method of fault. General operators can determine their own fault and note, maintenance it according to the brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation. Please remember the following suggestions before repairing: - Make sure that study the failure carefully before any operation. - Repair with the easiest way and most commonly used method. - Find the exact causes of failure and completely solve the fault. 1. Generator Sets Description of this section is for reference only. If the following failure occurs please contact the repairing agents. (Some models of control panel installed only parts of the following warning indicator light)IconIndicator LightReasonFault AnalysisLow oil pressurealarmLow oil pressurealarmWhen oil pressure does notreduce normally, the light is on.-General because of a lack of oil or lubricationsystem failure caused by (refueling or replacingthe oil filter)-When occurs this fault should automaticallyshutdown generator sets immediately.High watertemperaturealarmHigh watertemperaturealarmWhen the water temperaturehas risen to a level higher thanor equal to the sensor setting,the light is on.-General because of a lack of water or oilshortage, or overload.-When occurs this fault should automaticallyshutdown generator sets immediately.Low fuel levelalarmLow fuel levelalarmWhen a fuel level has beendetected by the sensor fitted tothe daily tank, the light is on.-General because of a lack of water or oilshortage, or overload.-When occurs this fault should automaticallyshutdown generator sets immediately.Battery chargerfault alarmBattery chargerfault alarmIf the charging system has fault,when engine running, the light isoff.-Battery charging system fault caused.-The light is on at the initial start, when thecharger reaches a certain speed, the light is off.-This failure will not lead to automatic shutdowngenerating units.Crank failurealarmCrank failurealarmWhen the generator set failedthree times (or six times) in arow starting, the light is on.-Oil supply system or re-start the system failurecaused.Overload orbreaker trippingalarmOverload orbreaker trippingalarmWhen overloading or Shortcircuit, the light is on. Trippingcircuit breakers cause generatorset load out.-In this fault, it need to load or unload some partsto eliminate short-circuit, and then re-close thecircuit breaker.Introduction of Maintenance grade(Interval) for the generator set A Level Maintenance Interval (Daily Maintenance)1. Check Daily Report of Genset .2. Check fuel level and coolant level. 3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or other damage.4. Check the Air filter. The air filter should be replaced when necessary .5. Release fuel tank and fuel filter's water and sediment.6. Check the water cooling filter.7. Check starting battery and electrolyte, add electrolyte when necessary. 8. Check the starter, check noisy defect.9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.B Level Maintenance Interval (Less than 400 hours)1. Repeatedly check A Level Daily Maintenance steps.2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice and real fact. 3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF Grade of American Petroleum Institute.4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or it can be replaced. The replacement must be according to the environment and real fact.5. Replace the cooling system and add coolant concentration.6. Clean the crankshaft and inlet, outlet air- filter net. C Level Maintenance Interval (2000-3000 hours), Please do as follows:1. Repeatedly check A and B Level Daily Maintenance steps.2. Remove the tap of valve, clean and wash oil dirt and sludge.3. Fasten snails from each part (including running parts and fixed parts)4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.6. Check and adjust valve clearance.7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; clean and wash water tank radiator fins, then check the using capability of thermostat.Current Repair (D Level Maintenance)(3000-4000 hours)1. Check valve, valve seat and other wearing, repair or change it when necessary.2. Check P pump, quality of injection, repair and adjust it when necessary.3. Check and adjust connecting rod and fastening twisting torque.4. Check and adjust valve clearance.5. Check the trip of injector.6. Check and adjust tension of fan and generating belt.7. Clean and wash accumulation of carbon in inlet pipes.8. Clean and wash the core of air cooler.9. Clean and wash the whole oil lubrication system.10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.Medium Repair (6000-8000 hours)1. Including the items of minor repair.2. Disassemble generator(except crankshaft)3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.4. Check fuel supplying system, adjust oil pump and injector.5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.Overhaul (9000-15000hours)1. Including the items of intermediate repair.2. Disassemble all the parts in the generator.3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake and exhaust valve, a whole set of tools for generator repair 4. Adjust oil pump, injector and replace pump core, injector5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.