IPDB › China Industry › Industrial Equipment & Components › Compressor
Screw Air Compressor Full Unit 75kw1
Compressor, Air, Compressor
Xuzhou Nevermore Water Purification Technology Co., Ltd.
Preview:
Product Description Dormant backlight brightness0000Used to set the brightness of the backlight when the controller is un-operated for a long time. Gas loading pressure(Mpa)00.801. The pressure is higher than this value, and is in theloading operation state, controls the air compressor tounload the movement.2. The setting value of gas supply loading pressure cannot be greater than this value, and the "gas supply andunloading pressure" is limited by the "high unloadingpressure limit" in the manufacturer's parameters.Fan motor start temperature(oC)0080When the exhaust temperature is higher than the set value of the air compressor, control the fan operation.Fan motor stop temperature(oC)0070When the exhaust temperature of the air compressor is lower than the value set here, stop the fan from running.Motor Starting delay time(s)0008Set the starting time of the motor, start the time whenthe motor starts, in this time, the motor currentoverload is not protected.Fan motor Starting delay time(s)0003Set the starting time of the fan motor, start the timewhen the fan motor starts, in this time, the fan motorcurrent overload is not protected.Star angle delay time(s)0006motor star angle step-down start delay time.Load delay time(s)0002After the motor angle runs, the delay loading time.Empty load delay time(s)0600Air compressor allows the longest continuous no-loadoperation time, after this time automatically stop running, into the empty car too long stop state.Shut down delay time(s)0010When normal shutdown, the air compressor immediately noload operation, no load operation this setting time afterthe stop operation.Restart delay time(s)0100After the normal stop, the empty car stops for too longor the malfunction stops, the air compressor can berestarted only after the time is set up here.Drainage opening delay time( s ):0002When automatic drainage control, continuous drainage time (spare).Drainage off delaytime(min):0060When automatic drainage control, drainage interval (spare).Soft start delay time(s ):0006After this delay time, enter the loading delay time.(This parameter only works if the model is set to softstart).Load mode:Manual/Auto maticMode : the pressure is higher than the "unloadingpressure" automatically unload ; the rest of the cases, bythe loading and unloading key control.Mode : the controller automatically controls the loading and unloading of the air compressor according to the pressure and the set loading and unloading pressure.MenuSettinginitialvalueFunction descriptionGas loadingpressure(MPa)00.651.The loading mode is set to be automatic,when the air compressor is in the state of automatic unloading,thepressure is lower than this value to control the automaticloading and running of the air compressor2.When the air compressor stops for a long time,thepressure is lower than this value and the operatingconditions are available.The controller automaticallystarts the operation of the air compressor.MenuInitial valueFunction descriptionOil filter using time0020HOil filter total using time.Oil separator using time0020HOil separator total using time.Air filter using time0020HAir filter total using time.Lubricating oil using time0020HLubricating oil total using time.Grease using time0020HGrease total using time.Factory code00000000Display factory code.Power voltage0000VDisplay power voltage.MotorelectricityA:000.0AB:000.0AC:000.0ADisplay motor electricity.Fan motor electricityA:000.0AB:000.0AC:000.0ADisplay fan motor electricity.Motor RPM0000 RPMAccording to the read frequency of the motor, the calculated real time speed of the motor is displayed.Motor output frequency000.0 HzDisplay current motor Frequency converter output frequency.Motor output electricity000.0 ADisplay current motor Frequency converter output electricity.Motor output voltage000.0 VDisplay current motor Frequency converter output voltage.Motor output Power000.0 KwDisplay current motor Frequency converter real-time output Power.MotorElectricity consumption0000000.0K w.HDisplay controller according to the motor Frequency converter output real-time Power,Electricity consumption.MotorTotalElectricity consumption0000000.0K w.HDisplay controller according to the motor Frequencyconverter output real-time Power,total Electricityconsumption.Pressure00.00MPa Integral coefficient00.00 Motor state0000The controller displays the running state register values read from the host Frequency converter to the motor statusdisplay area.Malfunction0000The controller displays the value of the malfunctionstate register read from the host frequency converter tothe malfunction display area.Write frequency000.0Controller displays the motor frequency value obtained out calculate by PID operation here.Fan motor RPM0000 RPMAccording to the reading from Fan motor frequency,Display calculate Fan motor real-time RPM.Fan motoroutputfrequency000.0 HzDisplay current Fan motor Frequency converter output frequency.Fan motoroutputelectricity000.0 ADisplay current Fan motor Frequency converter output electricity.Fan motoroutput voltage000.0 VDisplay current Fan motor Frequency converter output voltage.Fan motor output Power000.0 KwDisplay current Fan motor Frequency converter real-timeoutput Power.Fan motor Electricity consumption000000.00K w/HDisplay controller according to the Fan motor Frequencyconverter output real-time Power,total Electricity consumption.Fan motor total Electricity consumption000000.00K w.HDisplay controller according to the Fan motor Frequencyconverter output real-time Power, total Electricity consumption.Fan motor state0000Controller obtained by Fan motor Frequency converterreading operation state register value, Display to Fanmotor state Display area.malfunction0000Controller obtained by Fan motor Frequency converterreading malfunction state register value,Displays tomalfunction Display area.Write frequency000.0Controller displays the fan motor frequency valueobtained out calculate by PID operation here.Date0000-00-00Display date of production.Currentoperating time0000:00:00Air compressor current operating time.Current load0000:00:00Air compressor current load time.SoftwareVersionCK0000M0000 Check word 10000 3FFF Check word 27FFFFFFF_1 Input port state1 2 3 4 5 6 7 8 9 10 1: Corresponding to the input state of the 5th switching quantity; 2: Corresponding to the input state of the 6th switching quantity; 3: Corresponding to the input state of the 7th switching quantity; 4: Corresponding to the input state of the 8th switching quantity; 5: Corresponding to the input state of the 9th switching quantity; 6: Corresponding to the input state of the 10th switching quantity;When the terminal is closed, the circle color in the input port stateis red, and when the terminal is broken, the circle color in the input portstate is light red.Output port state1 2 3 4 5 6 7 8 9 10 1: Corresponding to terminal 17 relay output ; 2: Corresponding to terminal 16 relay output ; 3: Corresponding to terminal 15 relay output ; 4: Corresponding to terminal 14 relay output ; 5: Corresponding to terminal 13relay output ; 6: Corresponding to terminal 12relay output ;When the terminal is closed, the circle color in the output port stateis red, and when the terminal is broken, the circle color in the outputport state is light red.Power-frequenc y motor ¢UI000000.0KwDisplay controller sample by the motor real-time electricity and real-time voltage product.Power-frequency motorElectricityconsumption0000000.0Kw.HWhen the model is power frequency, the power consumption ofthe motor calculated by the controller is displayed. (forinformation only)Power-frequency motor totalElectricityconsumption0000000.0Kw.HDisplay the poPower-frequency Fan motortotaElectricityconsumption000000.00Kw.HDisplay the power frequency of the air compressor fan motorcalculated by the controller and the accumulative powerconsumption.(for information only)wer frequency of the motor of the aircompressor calculated by the controller, and the accumulativeelectricity consumption. (for information only)Power-frequenc y Fan motor ¢UI000000.0KwWhen the power frequency of the fan motor is running, thepower consumption of the fan motor calculated by the controlleris displayed. (for information only)Power-frequenc y Fan motor Electricity consumption000000.00Kw.HWhen the power frequency of the fan motor is running, thepower consumption of the fan motor calculated by the controlleris displayed. (for information only)Power-frequency Fan motortotaElectricityconsumption000000.00Kw.HDisplay the power frequency of the air compressor fan motorcalculated by the controller and the accumulative powerconsumption.(for information only)Start/stop mode:Local/Remot eLocal mode: remote boot terminal is not functional. Remote mode: remote start terminal function is effective.Note : when a hardware input terminal is set to "remote bootenable", the starting and stopping mode is determined bythe state of the hardware. The terminal is remote whenclosed and local when disconnected. This setting does notwork.Operation mode:Power-frequency/softStarting/main Fan motorVariableFrequency/Fan motorVariableFrequency/MotorVariableFrequencyAccording to the demand, the user chooses the type of air compressor.According to the selected model, refer to the corresponding electrical wiring.Communication address:0001The communication mode is the communication address of the controller when the computer or linkage is used.Adjust the back brightness0004Adjust the back brightness, the higher the value, the stronger the brightness. Adjustable brightness of 1 / 7).Communication mode:Prohibition/ linkage /computerWhen it is set to be prohibited, communication does not work ;Set to communication, as slave, according to the MODBUS RTU protocol to communicate with the external equipment, baud rate: 9600; data format : 8N1; check bit : even check.When set for linkage, multiple air compressors can beoperated in a network.Pressure:Mpa/PSI/BARWhen set to Mpa, the pressure-related parameter units are displayed as Mpa.When set to PSI, the pressure-related parameter units are displayed as PSI. (Standby)When set to BAR, the pressure-related parameter units are displayed as BAR. (Standby)Temperature:oC/oFIf set to oC, the unit of parameters related to temperature is shown as oC.If set to Fahrenheit, the unit of parameters related to temperature is shown as Fahrenheit. (standby)LanguageEnglishEnglish view.Userpassword:****Modifiable user password ; can be reset with old user password or factory password.
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.