CIPDB › China Industry › Instruments & Meters › Test Instrument
Digital Automatic Four-point Method Wenner Method Grounding Soil Resistivity and Earth Resistance Tester1
Test InstrumentSoil Resistivity TesterEarth Resistance Tester
Weshine Electric Manufacturing Co., Ltd.
Preview:
Product Description Product DescriptionThe Earth faults are hazardous and hence need proper earthing to prevent fault current from entering into anybody or metallic object. The purpose of earthing is to minimize the effect of transient voltage that occurred due to a strike of lightning.What are the methods of measuring earth resistance?There are different earth resistance measurement methods used depending on the type of neutral system, the type of installation (residential, industrial, urban environment, rural environment, the possibility of cutting off the power supply. Four variables affect the earth resistance of a grounding system which includes:1. The composition of the soil2. The moisture content of the soil3. The temperature of the soil4. The depth of the electrodeThe resistance of the earth electrode depends upon the resistivity of the soil in which the electrode is inserted. Therefore, it is crucial to measure the resistivity during the design of any earthing installations.Earth resistance is the resistance of the ground electrode measured to perform a resistance check. With additional measurements like the voltage, the test electrode moved 10% of the original voltage electrode to the earth system, separating it from the initial position and 10% closer than its original position. When both of them agree with the measurement within the required level of accuracy, the test stakes are placed in a correct position, and the resistance can be obtained by averaging all three results.Before starting any earth resistance measurements, the maximum value for correct earthing needs to be measured. There are six basic test methods to measure the earth resistance:1. Four-point method (Wenner method)2. Three terminal methods (falloff potential method/ 68.1% method)3. Two-point method (dead earth method)4. Clamp-on test method5. Slope method6. Star delta methodBased on the methods mentioned above, Weshine have developed a Earth Tester Series (VS-3000 series), which combines the new lightning protection grounding resistance detection standard, specially for on-site measurement of earth resistance, soil resistivity, grounding voltage, AC voltage. PRODUCT INFORMATIONProduct NameDigital Earth Resistance TesterTypical ApplicationMeasurement of earth resistance, soil resistivity, grounding voltage, AC voltage.Testing MethodFour-point method (Wenner method)Test RangeEarth Resistance0 to 200 kΩSoil Resistivity0.000 to 9999 kΩ·mEarth VoltageAC 0.001 to 600 V(50Hz/60Hz) ResolutionEarth Resistance0.001 ΩSoil Resistivity0.01 ΩmEarth Voltage0.001 V AccuracyEarth Resistance1.0.000 to 10.00 kΩ: ±2%rdg±5dgt2.10.0 to 100.0 kΩ: ±3%rdg±5dgt3.100.0 to 200.0 kΩ: ±3.5%rdg±5dgtSoil Resistivityρ=2πaR (a:1 m~100m);π=3.14)Earth Voltage±2%rdg±5dgt(50Hz/60Hz)Weight3 kgDimension320 x 275 x 145 mmModel NumberVS-3004CertificatesCE; EMC; LVD; ISO; IEC;FeedbackCompany Profile
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...