CIPDB › China Industry › Instruments & Meters › Test Instrument
Underground Cable Fault Locator Tdr Underground Cable Fault Locator Cable Fault Test System Cable Fault Path Meter Cable Fault Tester/Detector Locator1
Test InstrumentCable Fault LocatorCable Detector
Kvtester Electronics Technology Co., Ltd.
Preview:
Product Description DescriptionTo test the HV arcing fault of cable, earthing high &low resistance, short circuit and breakage of the cable, poor contact, etc. If equipped with fault locator, it can decide the exact broken position of the cable ,applies to power cable in various type, voltage and communication cable Prodcut FeaturesMulti functional, safe, fast speed and accurate. It uses LV impulse method and HV flashover method to test, can test kinds of fault of the cable, if equipped with sound locator, can accurately the position of the fault pointHigh precision, adopts high-speed sampling technique, A/D sampling speed is 100MHz, resolution is 1m, detection blind area is 1m.High degree of intelligence, test results auto displayed by LCD.Can store and review the waveform and parameters, these information will not loss after power off.Dual display, compare the measured waveform and normal waveform of the fault cable, benefit to further detection of the fault.With function of wave form expansion ratio, change the proportion of the waveform, expand the waveform to test.Directly display the direct distance or relative distance between fault point and measured point.Can modify the speed according different measured cable.Portable design , small in volume , with rechargeable battery, easy to carry and operate. Product Technical ParameterCable Fault DetectorModel:ZC-700AApplicationsThis cable fault detector can test all types powercable (voltage class 1kV~35kV) , local cable, FMcommunication cable, coaxial cable, shortcircuit, earth, high resistance leakage, highresistance flashover fault of the metal overheadlines, and the broken & poor contact of thecable. It also can test the length of the cable andthe speed of the electric wave on the cable. Longest measured distance32km (100km for open wire ) Detection blind area:1m Reading resolution1m Power consumption:5VAService conditionstemperature: 0oC~+40oC(extreme temperature: -10oC~+ 50oC)Relative humidity: 40oC(20~90)%RHAtmospheric pressure (86~106) Kpa Dimension225mm×165mm×125mm
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.