CIPDB › China Industry › Instruments & Meters › Test Instrument
Battery Life Cycle Tester Battery Charging and Discharging Module Testing Machine1
Test InstrumentBattery TesterBattery Discharge Tester
Shenzhen Hongda New Energy Co., Ltd.
Preview:
Product Description Product Description HONGDIAN Battery charging and discharging tester is a special instrument for testing lithium battery pack, lead-acid battery pack, portable mobile power module and other battery packs with full series voltage 30V, 60V, 100V, 120V. The equipment has an advanced modular design and is equipped with a high-performance digital signal processor. It has powerful floating-point computing ability, multi-task real-time operation, all channels can be controlled independently, and it supports cross-device operation, multi-channel parallel master-slave synchronization technology, and the master-slave clock error is less than 1 ms. The voltage and current accuracy of the conventional model is five ten thousandths, and the customized model can reach two ten thousandths. It supports automatic current grading and the dynamic response of current switching is ≤ 5 ms. The equipment realizes man-machine interaction, the channel information interface displays the equipment IP selection list, the display information and data unit can be set, the working mode color can be set, the process information can be displayed, and the test process is intuitive. The left side of the data analysis interface is a curve, and the right side is a data list, which can display curves or data independently or simultaneously. Support a variety of information to query historical data, and export reports in various formats. The process editing interface adopts script editing mode, and there are many types of work steps and deadline conditions to choose from. Product Parameters AC input parametersInput power supplyAC 380V±10% 50/60±5HzPower factor≥99%(full load)THDI≤5%(full load)Input impedance≥1 MΩFeedback efficiency≥92%(full load)DC output parametersVoltage rangeCharging Voltage: 0V ~ 150V Discharging Voltage: 6V ~ 150VVoltage Accuracy±0.05%FSVoltage Resolution1mVCurrent Range-240 ~ 240ACurrent Accuracy±0.05%FSCurrent Resolution1mACurrent Response Time10ms(10%FS ~ 90%FS)Charge/Discharge Conversion Time20ms(-90%FS ~ 90%FS)Channel Control ModeAll channels can be independently controlled.Auxiliary channelsEach channel is equipped with an auxiliary temperature channel.Working step functional characteristicsSupport experimental testingBattery cycle life test, battery capacity test, battery charge/discharge characteristic test, battery charge retention test, battery charge and discharge efficiency test, battery charge and discharge endurance test.Minimum recording time of data10msNumber of steps2000Cycles65535Cyclic nesting5Charge-discharge modeStanding, pausing, constant current charging CC, constant voltage charging CV, constant resistance charging CR, constant current and constant voltage charging CCCV, constant power charging CP, constant current discharging DC, constant power discharging DP, constant resistance discharging DR, DC internal resistance test (DCIR).Cut-off conditionVoltage, current, capacity, energy, time, power, cycle times, BMS parameters, user-defined advanced parameters (supporting one or more logical AND or combinations).Type of execution actionJump, Pause, Protect, Next485/DBC file importSupport file editing, saving and importing, 485/CA for each channel.DC internal resistance test (DCIR)It supports DCIR step and hardware real-time calculation, and supports (V1-V2)/(I1-I2) and (v1-v2)/I.Data export modeExcel and CSV format exportDefencive functionAC side protectionPower grid voltage over/under-voltage protection, surge protection, islanding protection, over/under-frequency protection, hardware over-temperature protection and self-detection protection, etc.DC side protectionBus overvoltage and undervoltage protection, hardware overtemperature protection, battery channel line reverse connection protection, etc.Battery side comprehensive protectionUpper and lower limits of total battery voltage, upper and lower limits of single battery voltage, upper and lower limits of battery temperature, upper and lower limits of battery charging and discharging current, upper and lower limits of battery capacity, BMS communication drop protection, network drop protection, etc.Power failure data protectionIt has the function of memory power failure protection, which can effectively avoid data loss caused by power failure or continue to run at the process breakpoint without modifying the process after incoming call.Protection gradesIP20Operating temperature range0oC-45oCCooling modeForced cold airNoise level≤80dB Detailed Photos Company Profile Our Advantages1.BMS free docking development2. Accuracy 0.05%3. Charge and discharge efficiency 92%4. Avant-garde voltage protection below 60v, without a protection board, our software can predict 7 volts in advance5. Our chassis appearance design is exquisite, small, in line with the optimal solution to heat dissipation effect, while using Delta fan, IGBT Infineon, the best configuration to ensure heat dissipation effect
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...