CIPDB › China Industry › Instruments & Meters › Dental Apparatus
Cbct Dental Panoramic Xray Machine Fov16*19 Oral Maxillofacial Conical Beam Computer1
Dental ApparatusDental CbctAtom Max Dental Cbct Phantom Cars Model 131)
Henan Forever Medical Co., Ltd.
Preview:
Product Description Product Description Dental CBCT Panoramic CBCT Scan Machine3D X-Ray Panoramic Imaging FOV 18*10 Oral Maxillofacial Conical Beam ComputerYJ-QD0124 A Whole New HorizonThe high-performance CMOS detector supports stepless regulation, with a maximum FOV of 16x9 cm, and a minimum voxel of 0.05 mm. The skull acquisition mode supports 3S UF scanning, and minimum pixelation of 99 um, guaranteeing fast acquisition of high-quality images.-Maximum FOV of 16x9-Minimum voxel of 0.05 mm-CMOS detector-0.3s UF scanning Detailed Photos De-motion artifact image quality upgrade Multiple hardware coordination, fast and easy positioning, comfortable adjustment and stable shooting, reduce motion artifacts from the source Integrated sliding seat, perfect for a variety of shooting scenes, effectively avoid body movementElectric collar holder, 0.1mm lifting accuracy, combined with adaptive head clip, accurately lock the shooting positionAnti-motion monitoring system, beyond the range of motion, prompt to stop exposure Lateral position independent lifting, three control methods, convenient to complete position adjustmentModel based iterative bone-hardeningcorrection. Model based iterative bone-hardening correctionThe model based osteosclerosis correction algorithm eliminates the hardening artifacts caused by more dense bone tissue such as head and teeth, and makes the tissue structure clearerAI-MAR IntelligentGhost Image RemovalIt uses the innovative AI-MAR intelligent ghost image removal technology to eliminate metal artifacts and provide a more accurate CTimage.Its intelligent demetalization algorithm sets different parameter sintelligently, based on the size and density of metal objects, and process-es metals of different textures and sizes efficiently and optimally. Smart Removal of Ghost ImagePerfect Image QualityIt adopts the total variation wavelet-based denoisingtechnology/algorithm in which the combination of frequencydomain and time domain suppresses noise more efficiently toensure better resolution of the digital images.Smart Removal of Ghost ImagePerfect Image Quality MODEL-BASED ITERATIVE BONE-HARDENING-CORRECTION Its innovative model-based iterative bonehardening-correction technology eliminates the artifacts caused by dense bone tissues such as head and teeth, improving the clarity of tissue structures as well as the accuracy of clinical diagnosis through the model-based bone-hardening-correction algorithm. DYNAMIC FOCUSING TOMOSYNTHESIS ALGORITHM Adopts the dynamic focusing tomosynthesis algorithm to intelligently identify different dental arch shapes to generate five high-definition panoramic images at one time. The dynamic focusing tomosynthesis technology permits optimal image formationfor patients with different dental arch shapes.Dynamic focusing tomosynthesis algorithmAutomatically adjust the grayscale and sharpness according to the patient's individual jaw arch shapeAI-MAR intelligent artifact removal technologyAccording to the size and density of metal objects, intelligent parameters are set to effectively eliminate metal artifactsTotal Variation Wavelet-Based Denoising technologyThe total variational denoising algorithm based on wavelet combines both frequency domain and time domain to suppress noise to a greater extentMultiple image algorithm ensures image quality Avoid ineffective radiation and improve the efficiency of medical treatment Standard Professional Orthodontic SoftwareThe software supports automatic tracing, in which lateral cephalograms are integrated with the patient's lateral view using fixed-point posterior integration, after which changes in the soft tissue profile caused by the adduction of upper and lower anterior teeth, rotation in the maxillary and mandibular planes, and genioplasty can be studied. it also helps to predict the mandibular growth trends in the patient.Product nameOral-maxillofacial conical beam computer tomography equipmentTube voltage60kV-100kVTube current2mA-12mASpace required for installation2500mm*1304mm *2340mmVisual field FOV18*14CM, 16*12CM, stepless adjustableEffective X-ray exposure timeCBCT: 8s, 18s or 24s Pano: 14s Ceph: 0.8s, 3s or 10sLaser positioningFive laser beams Company Profile
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...