CIPDB › China Industry › Instruments & Meters › Electronic Instrument
Portable Three-Phase Intelligent Phase Volt-Ammeter Digital Phase Va Meter AC Voltage Range 0 to 600V Current 0 to 30A Three Clamps Phase Meter1
Electronic InstrumentThree Phase Voltammeter3 Phase Clamp Phase Voltammeter
EP HIPOT ELECTRIC CO., LTD.
Preview:
Product Description General Information:EP8410B The three-phase intelligent phase voltammeter is a multifunctional intelligent instrument designed for on-site testing. It consists of a host, current clamps (3), and test lines (4). The host uses a 3.5-inch true color LCD screen, graphical menu interface display, vector diagram instructions. The design of the small clamp head of the current clamp is easy to operate, and it is very suitable for places with dense wiring. The instrument can measure three-phase AC voltage, current, phase between voltages, phase between currents, phase between voltage and current, frequency, phase sequence, active power, reactive power, apparent power, without opening the circuit under test. Power factor, current vector sum, identify the transformer wiring group, inductive, capacitive circuit, test the secondary circuit and bus differential protection system, read out the phase relationship between the CTs of the differential protection groups, check the correct connection of the meter Otherwise, the maintenance of line equipment, etc., provides a safe, accurate and convenient smart instrument for the electricity inspectors. It is suitable for electric power, petrochemical industry, metallurgy, railway, meteorology, industrial and mining enterprises, scientific research institutions, metrology departments, etc. Especially suitable for electric energy billing system and relay protection system.Technical Specifications:1. Baseline conditions and working conditions ItemBaseline conditionsWorking conditionsRemarkAmbient temperature23oC±1oC-10oC~40oC/Ambient humidity40%~60%<80%/Signal waveformSine waveSine waveβ=0.01Signal frequency50HZ±1Hz45Hz~65Hz/Working voltage7.4V±0.5V7.4V±1V/Current amplitude when measuring phase frequency phase sequence1A±0.1A1mA~30ACheck general specifications for detailsVoltage amplitude when measuring phase frequency phase sequence100V±10V1V~600V/Current amplitude when measuring power factor1A±0.1A10mA~30A/Voltage amplitude when measuring power factor100V±10V10V~600V/External electric field, magnetic fieldShould be avoidedThe position of the test wire under testThe tested wire is at the approximate geometric center of the clamps2. General specificationsFunctionSimultaneously test the current, voltage, phase, frequency, phase sequence, active power, reactive power, apparent power, power factor, current vector sum in the three-phase 380V / 220V power system to determine the transformer wiring group, inductive, capacitive Circuit, test the secondary circuit and bus differential protection system, read out the phase relationship between the CTs of the differential protection groups, check the correctness of the wiring of the watt-hour meter, repair the line equipment, etc. PowerDC 7.4V large-capacity rechargeable lithium battery, USB charging interface, continuous working for about 10 hours when fully charged.Rated currentAbout 180mA MaxDisplay mode3.5 inch true color LCD displayMeter size LWH:196mm×92mm×54mmClamp sizeφ7.5mm×13mm Sampling rateAbout 3 times / secMeasuring rangeAC voltage: 0.00V ~ 600VAC current: 0.0mA ~ 30APhase:0.0°~360.0°Frequency:45.00Hz~65.00HzActive power:0.0W~12kWReactive power:0.0VAR~12kVARApparent power:0.0VA~12kVAPower factor:-1~+1Current vector sum:0mA~60AResolutionVoltage:AC 0.01VCurrent:AC 0.1mAPhase:0.1°Frequency:0.01HzActive power:0.1WReactive power:0.1VARApparent power:0.1VAPower factor:0.001Current vector sum:1mAPrecision(Under baseline conditions)Voltage:±(0.5% measuring range)Current:±(0.5% measuring range)Phase: ± 1 ° (Phase error under working conditions: ± 3 ° from 10mA to 30A; ± 5 ° below 10mA. When the current value is less than 5mA, in order to ensure that the current is accurately measured on the current phase, do not perform voltage measurement In the phase test of voltage to current, in order to ensure the accuracy of the measurement, the voltage needs to be not less than 5V and the current is not less than 5mA)Active power: ± (1.0% of range)Reactive power: ± (1.0% of range)Apparent power: ± (1.0% of range)Frequency: ± (1.0% of range)Power factor: ± 0.03Phase sequenceNormal phase: U1, U2, U3 or I1, I2, I3 cursor flashes sequentially from left to rightReverse phase: U1, U2, U3 or I1, I2, I3 cursor flashes sequentially from right to leftDetection rateAbout 2 seconds / timeData retentionPress HOLD key to keep the data during the test, the "HD" symbol is displayedData storage99 groupsCharging interfaceUSB charging interfaceAutomatic shut-downAbout 15 minutes after starting up, the meter will automatically shut down to reduce battery consumptionBacklight functionYes, the backlight brightness can be adjustedVoltage detectionWhen the battery voltage is lower than 6.5V, the battery voltage low symbol is displayed, reminding the battery to charge, and automatically shut down within 10S.WeightHost: 350g (with battery)Current clamp:170g×3Total weight:about 1.35kgTest lead length1.5mCurrent clamp wire length2mWorking temperature and humidity-10oC~40oC, below 80%Rh Storage temperature and humidity-10oC~60oC, below 70%RhInput resistanceThe input impedance of the test voltage is: 1MΩWithstand voltageThe sine wave AC voltage of 1000V / 50Hz between the instrument circuit and the shell lasted 1 minuteInsulation≥100MΩ between instrument circuit and sheath shellSuitable for safety regulationsIEC61010-1 CAT III 600V, IEC61010-031, IEC61326, pollution degree 2More details on Three Clamps Intelligent Phase Volt-Ammeter please contact EP Hipot Electric, we have professional tech team to design correctly designed products and systems.
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.