CIPDB › China Industry › Instruments & Meters › Electronic Instrument
Multimeter Calibrator for 4.5-digit DMMs Calibartion TUNKIA TD18601
Electronic Instrumentmultimeter calibratormultifunction calibrator
Tunkia Co., Ltd.
Preview:
Product Description TD1860 Multi-function Calibrator 1. SummaryTD1860 is a multi-function calibrator with wide range and high precision, integrates AC\DC voltage source, AC\DC current source, DC resistance source, etc. The DC accuracy class is up to 0.01, and the AC accuracy class is up to 0.05. It's applied for calibrating 4.5 digits multimeter, voltmeter, ammeter, ohmmeter, power meter.2. FeaturesDC voltage output: ±(10 mV ~ 1100 V)DC current output: ±(3 μA ~ 22 A)(33 A optional)AC voltage output: 3 mV ~ 1100 VAC current output: 30 μA ~ 22 A(33 A optional)Sinusoidal wave frequency: 45 Hz ~ 1500 HzSimulated DC resistance:0 Ω ~ 220 MΩ2 MHz square wave frequency outputPhase output AC/DC power output Remote adjustment(optional) Clamp meter calibration(optional) Transducer calibration(optional) 3. Application ☆ Calibrate AC\DC electrical measuring instrumentsDCV output: ±(10 mV ~ 1100 V)DCI outpu: ±(3 μA ~ 22 A or 33 A)ACV output: 3 mV ~ 1100 V,45 Hz ~ 1500 HzACI output: 30 μA ~ 22 A or 33 A,45 Hz ~ 1500 HzRES output: 0 Ω ~ 220 MΩFrequency output: 1 Hz ~ 2 MHzCalibrate digital multimeter, AC/DC voltmeter, AC/DC ammeter, DC ohmmeter, frequency meter.☆ Calibrate AC\DC power metersCalibrate DC power meter, real power meter, phantom power meter, apparent power meter, power frequency phase meter and power factor meter. ☆ Calibrate clamp ammeter (optional)Equivalent to 1000AT current through input 20A current to the 50T Coil, which is suitable for calibrating DC clamp meters.☆ Calibrate AC/DC Transducer (optional)DC small-signal measurement. (Vmax: 12 V, Imax: 24 mA)Calibrate the proportional error of AC/DC voltage/current transducer.4. Panel Features☆ Front\Side PanelItemDescription1LCD touch screen.2Pulse frequency output terminal.3Input terminals for transducer.4Operation panel.5Foldable feets.6AC/DC current output terminals.7AC/DC voltage output terminals.8Simulated DC resistance output terminals. ☆ Rear panelItemDescription1Remote box interface.2RS232 communication interface.3Cooling vents.4Chassis ground binding post.5AC 220V power interface.6Foldable feets.7Handle: used for carrying instruments.5. Characteristics☆ Wide output range ☆ Multiple output\adjustment methods"Direct output" mode: the value output can be set directly by physical key or touch screen.Calibration of the analog pointer meter usually needs to test scale by scale, especially "differences between rising and falling" (the change caused by the rise and fall of the calibration point). Remote box can realize the coarse and fine adjustment of current or voltage. 6. Specifications6.1 DC Voltage Output RangeResolutionStabilityAccuracy[1]Max Burden (mA)Ripple Factor(%)24 hours(23±1)°C90 days(23±5)°C1 year(23±5)°C±(ppm*output + μV)100 mV1 μV40 + 564 + 1080 + 10300<0.5300 mV1 μV40 + 564 + 1080 + 10300<0.51 V10 μV40 + 1064 + 1580 + 15300<0.53 V10 μV40 + 1064 + 1580 + 15300<0.510 V100 μV40 + 10064 + 15080 + 150600<0.530 V100 μV40 + 15064 + 15080 + 150800<0.5100 V1 mV40 + 150064 + 150080 + 1500300<0.5300 V1 mV40 + 150064 + 150080 + 1500120<0.51000 V10 mV40 + 500064 + 500080 + 500040<0.5Note[1]:When the output is negative, the floor uncertainly is double. For example, when the output is 1 V, the accuracy is (80 ppm × 1 V + 30 μV);Output range: ±(10 mV ~ 1100 V)Short-circuit and overload protection6.2 DC Current OutputRangeResolutionStabilityAccuracy [1]Compliance Voltage (V)Ripple Factor (%)24 hours(23±1)°C90 days(23±5)°C1 year(23±5)°C±(ppm*RD + μA)30 μA100 pA96 + 0.02108 + 0.02120 + 0.0211<0.5100 μA1 nA96 + 0.04108 + 0.04120 + 0.0411<0.5300 μA1 nA96 + 0.04108 + 0.04120 + 0.0411<0.51 mA10 nA96 + 0.08108 + 0.08120 + 0.0811<0.53 mA10 nA96 + 0.08108 + 0.08120 + 0.0811<0.510 mA100 nA96 + 0.8108 + 0.8120 + 0.811<0.530 mA100 nA96 + 0.8108 + 0.8120 + 0.811<0.5100 mA1 μA96 + 8108 + 8120 + 811<0.5300 mA1 μA96 + 24108 + 24120 + 244<0.51 A10 μA96 + 80108 + 80120 + 803.5<0.53 A10 μA96 + 80108 + 80120 + 804<0.510 A100 μA96 + 800108 + 800120 + 8003.5<0.520 A(30 A)[2]100 μA96 + 800108 + 800120 + 8002.8<0.5Note [1]: When the output is negative, the floor uncertainly is double;Note [2]: 30 A range is optional.Output range: ±(3 μA ~ 22 A\33 A)Open-circuit and overload protection6.3 Simulated DC ResistanceRangeResolutionAccuracyAllowable Current90days(23±5)°C1year(23±5)°C±(ppm*output + Ω)0 Ω-5 mΩ5 mΩ1mA~ 300mA10 Ω100μΩ240 + 0.015300 + 0.0151mA~ 150 mA30 Ω100μΩ240 + 0.015300 + 0.0151mA~ 150 mA100 Ω1 mΩ120 + 0.015150 + 0.0151mA~ 80 mA300 Ω1 mΩ120 + 0.03150 + 0.031mA~ 40 mA1 kΩ10 mΩ80 + 0.1100 + 0.11mA~ 20 mA3kΩ10 mΩ80 + 0.2100 + 0.20.1mA~ 6mA10 kΩ100 mΩ80 + 1100 + 10.1mA~ 2mA30 kΩ100 mΩ80 + 2100 + 210μA~ 600 μA100 kΩ1 Ω80 + 10100 + 1010μA~ 200 μA300 kΩ1 Ω80 + 20100 + 201μA~ 60 μA1 MΩ10 Ω80 + 100100 + 1001μA~ 20 μA3 MΩ10 Ω80 + 300100 + 3000.25μA~ 6 μA10 MΩ100 Ω240 + 1k300 + 1k0.25μA~ 2 μA30 MΩ100 Ω400 + 3k500 + 3k25nA~600nA100 MΩ1kΩ1600 + 80k2000 + 80k25nA~200nA200 MΩ1kΩ4000 + 100k5000 + 100k2.5nA~ 45nAOutput range: 10 Ω ~ 220 MΩOver-current and reverse connection protection6.4 AC Voltage OutputRangeResolutionFrequency (Hz)AccuracyMax Burden (mA)[Source internal resistance]Harmonic (%)90 days(23±5)°C1 year(23±5)°C±(ppm*RD + mV)30 mV100 nV45≤F≤1k360 + 0.03400 + 0.03[1Ω]<0.51k<F≤1.5k540 + 0.03600 + 0.03<0.5100 mV1 μV45≤F≤1k360 + 0.03400 + 0.03[1Ω]<0.51k<F≤1.5k540 + 0.03600 + 0.03<0.5300 mV1 μV45≤F≤1k270 + 0.05300 + 0.05100<0.51k<F≤1.5k450 + 0.05500 + 0.05<0.51 V10 μV45≤F≤1k270 + 0.2300 + 0.2300<0.51k<F≤1.5k450 + 0.2500 + 0.2<0.53 V10 μV45≤F≤1k360 + 0.2400 + 0.2300<0.51k<F≤1.5k450 + 0.2500 + 0.2<0.510 V100 μV45≤F≤1k270 + 2300 + 2500<0.51k<F≤1.5k450 + 2500 + 2<0.530 V100 μV45≤F≤1k360 + 2400 + 2800<0.51k<F≤1.5k450 + 2500 + 2<0.5100 V1 mV45≤F≤1k270 + 20300 + 20400<0.51k<F≤1.5k450 + 20500 + 20<0.5300 V1 mV45≤F≤1k360 + 20400 + 20120<0.51k<F≤1.5k450 + 20500 + 20<0.51000 V10 mV45≤F≤1k270 + 200300 + 20040<0.51k<F≤1.5k450 + 200500 + 200<0.5Output range: 3 mV ~ 1100 VShort-circuit and overload protection6.5 AC Current OutputRangeResolutionFrequency (Hz)AccuracyCompliance Voltage (V)Harmonic (%)90 days(23±5)°C1 year(23±5)°C±(ppm*RD + μA)300 μA1 nA45≤F≤1k360 + 0.12400 + 0.1250<0.51k<F≤1.5k450 + 0.12500 + 0.12<0.53 mA10 nA45≤F≤1k270 + 0.6300 + 0.650<0.51k<F≤1.5k360 + 0.6400 + 0.6<0.530 mA100 nA45≤F≤1k270 + 6300 + 650<0.51k<F≤1.5k360 + 6400 + 6<0.5300 mA1 μA45≤F≤1k270 + 60300 + 6015<0.51k<F≤1.5k360 + 60400 + 60<0.51 A10μA45≤F≤1k270 + 200300 + 20015<0.51k<F≤1.5k360 + 200400 + 200<0.55 A10μA45≤F≤1k270 + 600300 + 6004<0.51k<F≤1.5k360 + 600400 + 600<0.520 A(30 A)[1]100μA45≤F≤1k270 + 4000300 + 40002.5<0.51k<F≤1.5k360 + 4000400 + 4000<0.5Note [1]: 30 A range is optional.Output range: 30 μA ~ 22 A or 33 AOpen-circuit and overload protection6.6 Sinusoidal Wave Frequency OutputRange[1]ResolutionAccuracy45.0000 Hz ≤ F ≤ 99.9999 Hz0.0001 Hz±0.01%100.000 Hz ≤ F ≤ 999.999 Hz0.001 Hz±0.01%1000.00 Hz ≤ F ≤ 1500.00 Hz0.01 Hz±0.01%Note [1]: The output mode is AC voltage or AC current. 6.7 AC/DC Power OutputFrequency Range (f)Voltage Range (U)Current Range (I)Optimum Accuracy%*power output [1][2]DC10 mV ~ 1100 V3μA ~ 22 A/33 A±0.0545 Hz ~ 65 Hz3 V ~ 600 V0.3 mA ~ 22 A/33 A±0.16.8 Phase and Power Factor Output(45 Hz ~ 65 Hz)PhasePower FactorAccuracyWATTSVARSλ=cosφPhasePower Factor0°90°1.000000.05°0.000%10°80°0.984810.05°0.015%20°70°0.939690.05°0.032%30°60°0.866030.05°0.050%40°50°0.766040.05°0.073%50°40°0.642790.05°0.104%60°30°0.500000.05°0.151%70°30°0.342020.05°0.240%80°10°0.173650.05°0.495%90°0°0.00000--Note [1]: Phase range: 0.000 ° ~ 359.999 °, fineness: 0.005 °Note [2]: Power factor range: -1 ~ 0 ~ 1, fineness: 0.000 1 6.9 Pulse Frequency OutputRange [1]ResolutionAccuracyShake1.000 00 Hz ≤ F ≤ 9.999 99 Hz10 μHz±(20 ppm*RD + 20 μHz)<20 ns10.000 0 Hz ≤ F ≤ 99.999 9 Hz0.1 mHz100.000 Hz ≤ F ≤ 999.999 Hz1 mHz1.000 00 kHz ≤ F ≤ 9.999 99 kHz10 mHz10.000 0 kHz ≤ F ≤ 99.999 9 kHz0.1 Hz100.000 kHz ≤ F ≤ 999.999 kHz1 Hz1.000 00 MHz ≤ F ≤ 2.000 00 MHzzNote [1]: The output type is TTL level. 6.10 DC Small-signal Measurement (optional)TypeRangeMeasurement RangeAccuracyDCV1 V±(0 ~ 1.2) V±(0.006%*RD + 0.004%*RG)10 V±(0 ~ 12) V±(0.006%*RD + 0.004%*RG)DCI2 mA±(0 ~ 2.4) mA±(0.006%*RD + 0.004%*RG)20 mA±(0 ~ 24) mA±(0.006%*RD + 0.004%*RG) 7. General SpecificationsPower supplyAC (220±22) V,(50±2) HzMaximum power consumption600 VAWarm up timeTwice the time since last warmed up, to a maximum of 30 minutes.Temperature performanceOperating temperature:0°C~40°CCalibration temperature:18°C~28°CStorage temperature:-20°C~70°CHumidity performanceOperating humidity:<80% @ 30°C,<70% @ 40°CStorage humidity:(20%~80%) R·H,No condensationCommunication interfaceRS232 Dimensions450 mm(W)× 505 mm (D) × 203 mm (H), excluding handles and feets.WeightAbout 19.5kg8. Ordering Information
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...