CIPDB › China Industry › Instruments & Meters › Dental Apparatus
Lk-U31 Dental Clinic Patient Monitor Price for Surgery1
Dental ApparatusDental EKG MonitorsDental Monitors
Zhengzhou Linker Medical Equipment Co., Ltd.
Preview:
Product Description LK-U31 Dental Clinic Patient Monitor Price for SurgeryPortable Patient Monitor performs monitoring of:ECG Heart Rate (HR) 2-channel ECG waveforms S-T segment analysis Arrhythmia (optional)RESP Respiratory Rate (RR) Respiration WaveformSpO2Oxygen Saturation (SpO2), Pulse Rate (PR) SpO2 PlethysmogramNIBP Systolic Pressure (NS), Diastolic Pressure (ND), Mean Pressure (NM)TEMPTemperature DATAIBPIBP DATAPortable Patient Monitor (Figure 1-1) is adaptable to adult, pediatric and neonatal usage. It can monitorvital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP. It integrates parameter measuringmodules, display and recorder in one device, featuring in compactness, lightweight and portability.Replaceable built-in battery facilitates transportation of patient. Large high-resolution display providesclear view of 5 waveforms and full monitoring parameters.The POWER switch is on the left quarter of the front panel (in Figure 1-1). The POWER indicator(inFigure 1-1) and the BATT indicator ( in Figure 1-1) lights when the device is powered on. TheALARM indicator flashes or lights when alarm occurs ( in Figure 1-1).The sockets of the sensors areat the right side. The recorder socket is at the left side. Other sockets and power plug-in are at theback.Do not immerse the connector in any liquid. After cleaning, dry the transducer thoroughly beforestoring. Slight discoloration or temporary increase of surface stickiness of the cable should not beconsidered abnormal If adhesive tape residue must be removed from the transducer cable, doubleseal tape remover is effective and will cause a minimum of damage to the cable if used sparingly.Acetone, Alcohol, Ammonia and Chloroform, or other strong solvents are not recommendedbecause over time the vinyl cabling will be damaged by these agents.Liquid Chemical SterilizationRemove obvious contamination by using the cleaning procedure described previously. Select asterilant that your hospital or institution has found to be effective for liquid chemical sterilizationof operating room equipment. Buffered gluteraldehyed (e.g. Cidex or Hospisept) has beenfound to be effective. Do not use quaternary cationic detergents such as zephiran chloride. Ifthe whole unit is to be sterilized, immerse the transducer but not the electrical connector intothe sterilant for the recommended sterilizing period. Be sure that the dome is removed. Thenrinse all transducer parts except the electrical connector with sterilized water or saline. Thetransducer must be thoroughly dried before storing.Gas SterilizationFor more complete asepsis, use gas sterilization.Remove obvious contamination by using the cleaning procedure described previously. Toinhibit the formation of ethylene glycol when ethylene oxide gas is used as the disinfectant, thetransducer should be completely dry.Follow the operating instructions provided by the manufacturer of the gas disinfectant.Related dental surgery products:
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...