CIPDB › China Industry › Instruments & Meters › Other Instruments & Meters
FTIR920 Building Glass Calibration Emissivity Detector1
Other Instruments MetersBuilding GlassCorrected radiation
Hunan Gonoava Instrument Co Ltd
Preview:
Product Description Product DescriptionFTIR920 Building Glass Calibration Emissivity Detector1. Light source: imported high-intensity air-cooled ceramic infrared light source, longer service life, better stability.2. Detector: imported low noise DLATGS detector, weak signal more sensitive, low noise, higher accuracy. 3. The whole machine: The whole machine is imported from Europe, using Michelson interference principle for infrared spectrum measurement, high measurement accuracy, a single scan only takes 3 seconds.4. Sample room: The use of large sample accessories design, the maximum can measure 300*300*20mm glass samples.5. Interferometer: multi-seal moisture-proof and dust-proof design, visual silicone window for easy observation and replacement.6. Moisture-proof dehumidification: the instrument comes with a heating dehumidification module, which effectively extends the life of the components in the instrument. It can be equipped with dehumidification drying box to enhance protection.7. Debugging: The energy of the interferometer can be adjusted without opening the cover, which is convenient for debugging.8. Maintenance: no need to open the host can be desiccant replacement, easy maintenance,9. Test software: Equipped with hemispherical emissivity measurement Chinese software can perform intelligent control of the instrument, measurement parameter setting, infrared spectrum data acquisition, spectral data processing, and data export (text format, Excel), test report printing, etc.FTIR920 Building Glass Calibration Emissivity DetectorProduct Parameters Classification of measurable samples35-300mmThickness ≤20mmBaseline flatness≤0.1%TWavenumber range7800-375cm-1Wavelength range1.282-26.667μmResolution1.0 cm-1Calculated wavelength range2.5-25μmWavenumber accuracy0.01cm-1Transmittance repeatability0.5%TBeam splitterImported multilayer coating KBrWorking modeTransmittance, absorbance, energySample chamber size200*260*160mmOverall dimension590*390*190mmweight26kgOperating voltageAC220V DC12V 40WSpectral bandwidthUltraviolet-visible :2.0nm,3.0nm,5.0nm;Near red 5.0-20.0nm(automatic, manual) Detailed Photos
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...