CIPDB › China Industry › Instruments & Meters › Electronic Instrument
TUNKIA TD3220 Portable AC Calibrator for On-Site Sampling1
Electronic Instrumentac sampling calibratorac sampling field calibrator
Tunkia Co., Ltd.
Preview:
Product Description TD3220 Portable AC Sampling And Transmitter On-site Calibrator1. SummaryTD3220 is a portable instrument that integrates functions such as three-phase power standard meter, DC small signal standard meter, wiring identification, harmonic analysis, waveform display, phase vector diagram, data management, etc. It is designed for Class 0.05 specifications and allows for real load calibration of AC sampling devices and transmitters in power systems. 2. FeaturesThree-phase voltage measurement range: 0~ 480 V.Three-phase current measurement range: 50 mA~ 12 A (direct measurement), 100 mA~ 120 A (clamp measurement).Large LCD touch screen display, intuitive value display and convenient operation.The power supply supports wide voltage mains input or battery power supply.Equipped with RS232 interface, which can realize data storage and remote transmission.Small size, light weight and easy to carry. 3. Application☆ Real Load Calibration of AC Sampling Devices (Standard Meter Method)TD3220 supports direct measurement of three-phase voltage, ranging from 10 V to 480 V, direct measurement of three-phase current from 0.05 A to 12 A, and three-phase current clamp measurement from 0.1 A to 120 A;Application 1 (direct current measurement)Suitable for calibrating single-phase/three-phase voltage sources, current sources, and power sources of level 0.2 and below in the laboratory or on site.Application 2 (Clamp measuring current)In the past, when testing on-site AC sampling devices, it was usually necessary to wait for a power outage for maintenance before disconnecting the circuit, stringing a standard ammeter into the loop for testing, or removing the tested meter to the laboratory for testing using the standard source method. When using a clamp meter to detect current, users can clamp the current wire into the clamp instead of cutting the circuit short, and then measure it online in real time. This instrument completes on-site inspections more quickly and conveniently, and can meet the requirements for daily inspection of the operating status of instruments. ☆ Real Load Calibration of AC and DC TransmitterIt has the secondary DC signal measurement function of the transmitter and supports a maximum DC 12V or 24 mA signal input.It measures the primary/secondary signal of the transmitter running online to complete the test of basic error, output ripple, and response time. ☆ Real Load Calibration of CT RatioIt can realize CT transformation ratio test. The instrument measures the primary signal of the CT through a large current clamp, and measures the secondary signal of the CT through a small current clamp, and calculates the CT transformation ratio and the phase relationship between the primary and secondary currents. This determines whether the CT operating status is good. 5. Instrument Appearance☆ Front PanelN0.Function1Power Cord Socket: mains power supply or lithium battery charging.2RS232 Terminal: connecting to a computer to transfer data through management software.3Power Supply Switch4Clamp-type Current Terminal Block: measuring current from 0.1 A to 120 A.5Three-phase Voltage Terminal Block: A wide range of voltage measurement from 10 V to 480 V can be achieved with one connection.6Three-phase Current Terminal Block: measuring current from 0.05 A to 12 A.7LCD Touch Color Screen: intuitive display of various electrical parameters and full touch operation, greatly improving the ease of use of the instrument.8DC Measurement Terminal Block: used for secondary signal measurement of the transmitter.6. Characteristics☆ On-site Portable DesignIt adopts imported protective box, which is light weight, small in size and good in protection, and is suitable for carrying to on-site work.It can be powered by 220 V mains power or the built-in large-capacity lithium battery, which is convenient for application in complex sites.It has a built-in large-capacity memory, which can quickly record the test data of the inspected equipment on site, up to thousands of pieces, and can be transferred to the supporting computer management software after the calibration work is completed. ☆ Good Human-Machine FunctionalityEquipped with a large LCD touch color screen, the value display is intuitive and the operation is very convenient.Multiple types of measured power, errors of the equipment being tested, and phasor diagrams can be displayed on the same screen.7. Specifications7.1 Three-phase Voltage/Current MeasurementThree Phase Measurement MethodRangeResolutionMeasurement Uncertainty( k = 2 )( ppm*RD+ppm*RG) [1]AC VoltageACVDirect Measurement110 V1 mV300 + 200220 V1 mV300 + 200480 V1 mV300 + 200AC CurrentACIDirect Measurement1 A10 μA300 + 20010 A100 μA300 + 200Clamp Measurement1 A10 μA0.2%*RG5 A10 μA0.2%*RG20 A100 μA0.2%*RG100 A1 mA< 50 A:0.2%*RG;≥ 50 A:0.5%*RG Note[1]:RD is the reading value, RG is the range value, the same below.Voltage measurement range: 10 V ~ 480 V, 6-digit decimal displayCurrent measurement range: 0.05 A~12 A @ direct measurement; 0.1 A~120 A @ clamp measurementFrequency range: 45 Hz ~ 65 Hz, measurement uncertainty: 0.01 HzPhase range: 0.00°~359.99°, measurement uncertainty: 0.05° (direct measurement); 0.2° (clamp measurement)7.2 Three-phase Power MeasurementPower ParametersMeasurement Uncertainty ( k = 2 )Direct MeasurementClamp MeasurementActive Power |cosφ| ≥0.50.05%*FS[2]0.2%*FS[2]Reactive Power |sinφ| ≥0.50.1%*FS[2]0.5%*FS[2]Apparent Power0.1%*FS[2]0.5%*FS[2]Power Factor0.00050.005Note[2]:FS=Voltage range value × current range value.Power factor measurement range:-1.0000…0.0000…1.00007.3 DC Small Signal Measurement (Transmitter Test)RangeMeasuring RangeMeasurement Uncertainty ( k = 2 )Ripple RangeRipple Measurement Uncertainty1 V± ( 0~1.2 ) V0.01%*RG0~500 mV1%*RG10 V± ( 0~12 ) V0.01%*RG2 mA±( 0~2.4) mA0.01%*RG0~1.2 mA1%*RG20 mA± ( 0~24 ) mA0.01%*RG 8. General SpecificationsPower SupplyMains power: AC (220 ± 22) V, (50 ± 2) Hz;Lithium battery power supply:continuous working for 8 hoursMaximum Power Consumption30 VATemperature PerformanceWorking temperature: 0°C~50°C; Storage temperature: -20°C~70°CHumidity PerformanceOperating humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°CStorage humidity: (20%~80%) R·H, no condensationAltitude< 3000 mWeightAbout 5 kgCommunication InterfaceRS232Dimensions365 mm(W) × 270 mm(D) × 170 mm(H) Company Profile
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...