CIPDB › China Industry › Instruments & Meters › Other Instruments & Meters
Keypower 800 Kw Load Bank for Generator Testing with Generator Tester1
Other Instruments MetersAC Load Bank500kw Load Bank
Fuzhou Gff Keypower Equipment Co., Ltd.
Preview:
Product Description Product DescriptionProduct ParametersResistiveOptional InductiveCapacitiveModelThree phasetesting capacitySingle phasetesting capacityPowerfactor Dimensions (mm)Weight(kg)Lagging powerfactorLeading powerfactorKPLB-100100 KW22 KW1.0 960*1150*1510350 0.8 0.9 or 0.95KPLB-200200 KW44 KW1.0 1560*1310*1650840 0.8 0.9 or 0.95KPLB-300300 KW66 KW1.0 1690*1440*17501085 0.8 0.9 or 0.95KPLB-400400 KW88 KW1.0 1900*1600*19001350 0.8 0.9 or 0.95KPLB-500500 KW110 KW1.0 1900*1600*19001400 0.8 0.9 or 0.95KPLB-60060O KW132 KW1.0 2100*1730*20001600 0.8 0.9 or 0.95KPLB-700700 KW154 KW1.0 2100*1730*20001800 0.8 0.9 or 0.95KPLB-80080O KW176 KW1.0 2400*2030*22002020 0.8 0.9 or 0.95KPLB-900900 KW198 KW1.0 2400*2030*22002150 0.8 0.9 or 0.95KPLB-10001000 KW220 KW1.0 2400*2030*22002275 0.8 0.9 or 0.95KPLB-11001100 KW242 KW1.0 3500*2270*21502800 0.8 0.9 or 0.95KPLB-12001200 KW264 KW1.0 3500*2270*21502900 0.8 0.9 or 0.95KPLB-13001300 KW286 KW1.0 3500*2270*21503070 0.8 0.9 or 0.95KPLB-14001400 KW308 KW1.0 3500*2270*21503150 0.8 0.9 or 0.95KPLB-15001500 KW330 KW1.0 3500*2270*21503250 0.8 0.9 or 0.95KPLB-1600160O KW352 KW1.0 6058*2438*25915800 0.8 0.9 or 0.95KPLB-17001700 KW374 KW1.0 6058*2438*25915900 0.8 0.9 or 0.95KPLB-18001800 KW396 KW1.0 6058*2438*25916000 0.8 0.9 or 0.95KPLB-19001900 KW418 KW1.0 6058*2438*25916100 0.8 0.9 or 0.95KPLB-20002000 KW440 KW1.0 6058*2438*25917450 0.8 0.9 or 0.95KPLB-21002100 KW462 KW1.0 6058*2438*25917500 0.8 0.9 or 0.95KPLB-22002200 KW484 KW1.0 6058*2438*25917600 0.8 0.9 or 0.95KPLB-23002300 KW506 KW1.0 6058*2438*25917760 0.8 0.9 or 0.95KPLB-24002400 KW528 KW1.0 6058*2438*25917860 0.8 0.9 or 0.95KPLB-25002500 KW550 KW1.0 6058*2438*25918100 0.8 0.9 or 0.95KPLB-26002600 KW572 KW1.0 6058*2438*25918250 0.8 0.9 or 0.95KPLB-27002700 KW594 KW1.0 6058*2438*25918500 0.8 0.9 or 0.95KPLB-28002800 KW616 KW1.0 6058*2438*25919000 0.8 0.9 or 0.95KPLB-29002900 KW638 KW1.0 6058*2438*25919500 0.8 0.9 or 0.95KPLB-30003000 KW660 KW1.0 6058*2438*259110500 0.8 0.9 or 0.95KPLB-35003500 KW770 KW1.0 12192*2438*289612000 0.8 0.9 or 0.95KPLB-40004000 KW880 KW1.0 12192*2438*289614500 0.8 0.9 or 0.95KPLB-45004500 KW990 KW1.0 12192*2438*289616500 0.8 0.9 or 0.95KPLB-50005000 KW1100 KW1.0 12192*2438*289617500 0.8 0.9 or 0.95KPLB-55005500 KW1210 KW1.0 12192*2438*289618500 0.8 0.9 or 0.95KPLB-60006000 KW1320 KW1.0 12192*2438*289620000 0.8 0.9 or 0.95 Technical SpecificationsModelKPLB-1000KPLB-1500KPLB-2000KPLB-2500 KPLB-3000Testing capacity0-1000KW0-1500KW0-2000KW0-2500KW 0-3000KWType of loadResistive/Inductive/Capacitive,PF=O~1.0 adjustableDutyContinousControl modeIntelligent/Remote controlCooling systemIndustrial grade axial fanPhaseThree phaseRated testing voltage690V~20KVRated frequency50/6OHZDimension [L*W*HJ[mm]6058*2436*259112192*2438*2896Weight [kg]5000 5800 6800 8000 9500 FAQLoad Bank FAQ1. What is a load bank?A load bank is a device designed to provide electrical loads for testing various power sources, Including Engine Generators, Battery Systems, UPS Systems, Inverters, Ground Power Units, Auxiliary Power Units, Aircraft Power Generators, Wind Generators, and Hydro Generators etc.2. Why is Load Testing Important?Load bank testing will save your time and money in the long run. It is how you determine the operating status of your primary power systems. It's also how you exercise backup systems to ensure they will be available when called upon. Load testing at start-up and during commissioning and maintenance will detect problematic conditions before they escalate and cause downtime. 3. What are the different types of load banks?Resistive, Inductive, capacitive and Resistive/Inductive combined 4. Can the Load Bank test at single phase?Yes, but the rating available is 1/6 of the rated testing capacity. 5. Is it possible to synchronize multiple Load Banks for Testing?Yes. Multiple Load Banks can be synchronized to test one generator but one Load Bank is not able to test multiple generators at the same time. 6. What is the operating environment for Keypower Load Bank?Our Load Banks are to be applied where altitude ≤2500m above sea level,ambient temp within -15oC ~ +55oC and relative humidity ≤98%. 7. What is the different between Keypower standard load bank and dual voltage?For example, a KPLB-500 @400V can test full 500kw @400V, and derating to 165kw only @230V 3 phase. Dual voltage KPLB-500 can test full 500kw @400V and @230V. 8. What is generator tester 8961?The generator tester 8961 is used for recalling the data from the generators you are testing. Then it can create the test report and sine wave forms. It is good for generator manufacturer and project commissioning. 9. Is the load bank weatherproof?Standard type isn't weatherproof, but optional air discharge duct and cam-lock connectors can be fitted on it to enable weatherproof. 10. Does the load bank support remote monitoring and control?Standard type doesn't support, but optional programmable Mitsubishi PLC can be fitted to support remote monitoring and control on laptop.
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...