CIPDB › China Industry › Instruments & Meters › Demonstrational & Teaching Utensil
Good Price Medical Teaching Equipment Half Body CPR Training Manikin with LED Light1
Demonstrational Teaching UtensilCPR Training ManikinTeaching Model
Suzhou Thriving Medical Equipment Corp.
Preview:
Product Description Product DescriptionAdvanced Half Body CPR Manikin with LED LightOur product has unique electronic compression depth and frequency detector.1.First right operation: the 4 indicate light on the left shoulder will be on.2.The lights off: lack of battery or operation mistake, ensure have good batteries3. When start the operation, yellow and green light will be offRed light: Press frequency 0-60 beats/minYellow light: Press frequency 60-80 beats/minGreen light: Press frequency 80-100 beats/minRight operation:Two green lights on Press frequency >100 beats/minGreen light flashing:compression depth insufficientAt any time, if the pressure is not deep enough, all lights will go out and the red light will flash.MaterialsFace skin, cervical skin, chest skin and hair are made of thermoplastic elastomer and using technique of plastic injection mould with high temperature.The manikin has features of likelike touch, realistic operation feel.Quick and convenientDeluxe hand-push human body hard plastic box, to prevent product damage, to ensure that the product arrives in your hands. Maintenance1. Disinfect after use, such as face skin, mouth and nose, chest skin, breathing pipe, air intake valve, etc., can be scrubbed and disinfected with cleaning liquid.2. When the lung sac device is broken and needs to be replaced, the chest skin can be opened, the cushion skin on the lung bag and the sensor blow pull rod are connected to take out the nail cap, remove the cushion skin, pull out the bellows at the connection of the lung bag and the tee pipe, replace the new lung bag according to the sample, assemble it as is, and restore the original.3.The simulation of human and computer monitors, placed in a ventilated and dry place, must not be placed in a wet or sun-exposed place, to prevent affecting the service life.4.Pay attention to the need for stable voltage when using. Note1, Mouth to mouth artificial respiration, must be padded with disinfection gauze face towel (one-time blowing film), one person to prevent cross infection.2.When operating hands should be clean, women please wipe lipstick and lip balm, to prevent dirty skin and breast skin, not allowed to use the original bead pen or other color pen to paint.3.When pressing the operation, be sure to press the rhythm of the working frequency to avoid the disorder of the program, if there is a disorder of the program, immediately turn off the main power switch of the control display and reopen it to prevent the service life of the control display. Packaging & Shipping Company Profile
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...