CIPDB › China Industry › Metallurgy, Mineral & Energy › Solar & Renewable Energy
High Quality 10kw 20kw 30kw Grid Tie Wind Turbine Inverter Sustainable Use Hybrid Solar System Certified Wind Power Controller1
Solar Renewable EnergyGenerator InverterPure Sine Wave Inverter
Jinan Deming Power Equipment Co., Ltd
Preview:
Product Description Function Introduction of CE ISO9001 Factory Price Pure Sine Wave Inverter DC AC 20KVA Inverter 380Vac 400Vac 415Vac:1. using IGBT from Mitsubishi or Infineon company as the power components2. using American ATEMEL company microprocessor as figure controller3. perfect protection and warning functions4. circuit frame compact, Max. Efficiency≥94%5. with wide input voltage range6. RS232/485 communication, multi communication interface can be selected7. big-screen English LCD or LED, perfect display, interface-friendly8. Isolate Trasnformers built-in, filtering and can supply inductive loads, water pumps, motors etc.On grid solar wind hybrid power system:On grid wind power system:On grid wind turbine controllerWGMC3K380WGMC5K380Wind turbine inputPower3KW5KWMax. Control power / current6KW/12A10KW/20ARated voltage of wind turbine (AC)380V380VInput voltage rangeAC0-600V0-600VDC0-900V0-900VBraking voltage (DC)Default550V±1%550V±1%Set range530-560V530-560VBraking current (DC)Default9A 15A Set range0-9A0-15ABraking timeDefault10-20 minSet range0-5000min* Generator overspeed controlDefault >300 rpm/minSet range0-1000 rpm/min* Over wind speed controlDefault 14 m/sSet range0-45 m/sManual controlManual brake, *remote control brake (with communication function)Automatic control functionDump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake, * electromagnetic brake* PV. InputRated power (increased)3KWp5KWpWorking voltage (DC)550V / 660V550V / 660VDC output parametersOutput voltage range (DC)0-550V0-550VConstant voltage (DC)520V±1%520V±1%520V±1%510-540V510-540V510-540VConstant current (DC)Default7.5A 12ASet range0-7.5A0-12AOn grid wind turbine inverterDMWG3KTLDMWG5KTLRated output power (AC)3KW5KWMax. Output power (AC)3.3KW5.5KWInput voltage rang (DC)0-800V0-800VMPPT Voltage range (DC)150V-700V150V-700VMax. Input current (DC)6.8A11.2ARated current6.2A10.2ATHD Current harmonic <3%(at rated power)Power factor>0.99Max. efficiency98%Allowable grid voltage range (AC)220V/380V/440V/480V (Three-phase)±20%Allowable grid frequency range50Hz/60Hz±10%Automatic operation conditionsDC input and power grid meet the requirements, and the inverter operates automaticallyRestart time after power failure2min(Adjustable)General parametersFunction Rectification, DC output, output voltage control, output current control, Dump load control, control parameter setting, wind turbine curve settingAutomatic protectionControl part: Over voltage protection, over current protection, reverse connection protection, lightning arresterInverter part: Polarity reverse connection protection, short circuit protection, island effect protection,LVRT,overheat protection, overload protection, ground fault protection, etcDisplayTouch screen, LCDMonitoring contentWind turbine voltage, current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speedProtection levelIP20(Indoor)IP65 (Outdoors)Telematics RS485/USB/GPRS/WIFI/Ethernet (optional)EnvironmentOperating amb. Temp. & Hum -30-60°C,<90% no condensationNoise (1m)<40dBRefrigeration modeForced air cooling Controller size / weight360*230*480mm 17kg360*230*480mm 18kgDump load size / weight400*400*250mm 12kg600*450*380mm 28kgInverter size / weight550*225*770mm 49kg550*225*770mm 59kg On grid wind turbine controllerWGMC10K380WGMC20K380WGMC30K380Wind turbine inputPower10KW20KW30KWMax. Control power / current20KW/40A40KW/80A60KW/120ARated voltage of wind turbine (AC)380V/400V380V/400V380V/400VInput voltage rangeAC0-600V0-600V0-600VDC0-900V0-900V0-900VBraking voltage (DC)Default550V±1%550V±1%550V±1%Set range530-560V530-560V530-560VBraking current (DC)Default30A60A90ASet range0-30A0-60A0-90ABraking timeDefault10-20 minSet range0-5000 min* Generator overspeed controlDefault >300 rpm/minSet range0-1000 rpm/min* Over wind speed controlDefault 14 m/sSet range0-45 m/sManual controlManual brake, *remote control brake (with communication function)Automatic control functionDump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake, * electromagnetic brake* PV. InputRated power (increased)5KWp5KWp5KWpWorking voltage (DC)550V / 660V550V / 660V550V / 660VDC output parametersOutput voltage range (DC)0-550V0-550V0-550VConstant voltage (DC)Default520V±1%520V±1%520V±1%Set range510-540V510-540V510-540VConstant current (DC)Default24A 48A72ASet range0-24A0-48A0-72AOn grid wind turbine inverterDMWG10KTLDMWG20KTLDMWG30KTLRated output power (AC)10KW20KW30KWMax. Output power (AC)11KW22KW33KWInput voltage rang (DC)0-800V0-800V0-800VMPPT Voltage range (DC)(DC)150V-700V150V-700V150V-700VMax. Input current (DC)2.4A44.9A67.3ARated current20.4A40.8A61.2ATHD Current harmonic <3%(at rated power)Power factor>0.99Max. efficiency98%Allowable grid voltage range (AC)220V/380V/440V/480V (Three-phase)±20%Allowable grid frequency range50Hz/60Hz±10%Automatic operation conditionsDC input and power grid meet the requirements, and the inverter operates automaticallyRestart time after power failure2min(Adjustable)General parametersFunction Rectification, DC output, output voltage control, output current control, Dump load control, control parameter setting, wind turbine curve settingAutomatic protectionControl part: Over voltage protection, over current protection, reverse connection protection, lightning arresterInverter part: Polarity reverse connection protection, short circuit protection, island effect protection, LVRT,overheat protection, overload protection, ground fault protection, etcDisplayTouch screen, LCDMonitoring contentWind turbine voltage, current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speedProtection levelIP20(Indoor)IP65 (Outdoors)Telematics RS485/USB/GPRS/WIFI/Ethernet (optional)EnvironmentOperating amb. Temp. & Hum -30-60°C,<90% no condensationNoise (1m)<40dBRefrigeration modeForced air cooling Controller size / weight400*230*550mm 23kg500*230*620mm 35kg500*230*620mm 38kgDump load size / weight690*450*530mm 36kg980*880*540mm 70kg980*880*540mm 70kgInverter size / weight690*275*770mm 42kg690*275*770mm 58kg690*275*770mm 65kgFAQQ1: Are you a trading company or manufacturer?We are a factory.Q2: How long is your lead time?It depends on the solution you require but generally 30 days. For more specific information, please don't hesitate to ask usQ3. How to ensure product quality? Our production strictly follows the ISO9001 quality control system. We give the green (pass) sign only when we finish several quality inspections and high-temperature high-pressure testsQ4.How about your payment and shipment?Payment: We accept T/T, LC, Western Union, Alipay, etc. terms of payment.Q5. Do you provide a warranty for the goods? And what are the terms of the warranty?Yes, we provide 24 months warranty for all the goods. Please, contact us for information regarding warranty, technical support, and any other questions
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.