IPDB › China Industry › Instruments & Meters › Analysis Instrument
Gc112A Lab Gas Chromatograph Analysis Instrument2
Analysis Instrument, Gas Chromatography Lab, Gas Chromatography Vials
Hangzhou West Tune Trading Co., Limited
Preview:
Product Description GC112A Gas ChromatographGC112A gas chromatograph is suitable for trace detection of environmental protection, air and water pollution, analyzing poisons, monitoring and research, biochemistry, clinical application, pathology and virus research, food, petrochemicals, petroleum processing, oil analysis, geological , prospecting research, organic chemistry, synthesis, and quarantine, especially fit for power system, industrial and mining frontline laboratories and schools.FeaturesSynchronous bidirectional control with touch screen on the GC112A.The 7-inch color touch screen on the GC112A can display the flow rate and pressure value of theelectronic gas path.The multi core, 32-bit embedded hardware system ensures the reliable operation of the instrument.One key start up function.The extendable synchronous external trigger function can initiate GC112A and workstation throughexternal signals, such as automatic sampling device, thermal analyzer and so on.The instrument has sound system self-checking function and malfunction automatic identificationfunction.The instrument has 8 external event interface with extendable functions, which can work with avariety of functional control valve, performing according to the set timing.The memory function can store 20-sample test modes.RS232 communication port and LAN port.N2000 chromatography workstation.SpecificationsOven: Inside capacity: 22LTemperature range: room temperature up 5oC-400oC Temperature accuracy: ±0.1 oCTemperature programming: 9 step Program total time: 9999.9 min Max heating rate: 0.1-60oC/minMax cooling rate: <=10mins(250oC-50oC)Sample Injector: Temperature range: room temperature up7oC~ 420 oCTemp control type: independentCarrier gas flow control type: constant pressure Max quantity: 3PcsType: Packed column or split Split ratio: displayPre column pressure range: 0-400kpa Pre column pressure accuracy: 0.1kpa Flow setting range: H2 0-200ml/minN2 0-150ml/minDetector: FID or TCDTemperature Range: room temperature up 7oC~ 420 oCMax installation Qty.: 2 Ignition model: automaticHydrogen Flame lonization Detector (FID): Logarithmic amplifierHigh Voltage Switch Control Baseline signal displayDetection limit: <=3x10 -12 g/s( sample: n-hexadecane)Overall Dimension & Weight: Power: 220V±22V, 50Hz±0.5Hz, 3000WPackage size: 735mmx725mmx835mm G.W.: 82kgN.W.: 70kgBaseline noise: <=5x10-14A Baseline draft: <=6x10 -13 A Dynamic range: 107RSD: <=3%Thermal Conductivity Detector (TCD): Sencitivity:8000mV.ml/mg (sample:n-hexadecane)Baseline noise: <=0.05mV Baseline draft: <=0.15mV/ 30min Dynamic range: 105
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.