IPDB › China Industry › Instruments & Meters › Analysis Instrument
Heat Flow Method Thermal Resistance R-Value Measurement Thermal Conductivity Tester1
Analysis Instrument, Thermal Tester, Thermal Conductivity Tester
Hunan Zhenhua Analysis Instrument Co., Ltd.
Preview:
Product Description Product Description DRX-II-RL Thermal Resistance Measurement Thermal Conductivity Meter (Heat flow method) Use: This thermal conductivity meter measures the thermal conductivity, thermal diffusivity, and hot-melt of different materials by using heat flow method. Refer to standard MIL-I-49456A The thermal conductivity of thin solid electric insulation heat transfer performance testing standards, D5470-06, ASTM E1530, ASTM C 518, ISO 8301, JIS A 1412, DIN EN 12939, DIN EN 13163 and DIN EN 12667 and other relevant international standards.Features: Automatic plate movement and sample thickness measurement, all test parameters and calibration data can be stored in the computer. Conduct temperature programming, data viewing and storage for calibration test and sample test. The instrument is used to test polymer materials, ceramics, insulation materials, composite materials, non-metallic materials, thermal pad, silicone grease, and other materials with low and medium thermal conductivity. Only small samples are needed. Thin films can be accurately measured using multilayer techniques.Product Parameters Main technical parameters: Hot surface temperature range: RT~ 200oC , resolution: 0.01 oCCold surface temperature range:0~99.9oC, resolution: 0.01 oCRefrigeration systemForced air-cooled, external water bath, liquid nitrogen coolingFlat-panel temperature control systemsautomatic control programmable data points 1-10Sample sizeDiameter 30mm, thickness 0.2 -30mm Range of Thermal resistance(r-value)0.000005 ~ 0.05 m2·K/WRange of thermal conductivity(λ)0.015~50w/m.KAccuracy≤±3%Heat flow meterAdopt high precision heat flow meter Pressure range0-1000NDisplacement range0-30.00mmRepeatability1% Accuracy±3%Environmental conditionroom temperature: 18~25oC, humidity: 20~80%RHData result analysisAutomatic thermal analysis software, which can analyze and output testing parameters fast and accurately and data print out, Windows 10/ 11 EnglishSupply voltageAC 220V±5%, power: 3.0kw Detailed PhotosOur servicesCompany Profile
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.