IPDB › China Industry › Instruments & Meters › Analysis Instrument
Multichannel Potentiostat Galvanostat 8-Channel Potentiostat Model CS310X (Option D)1
Analysis Instrument, Multichannel Potentiostat, Potentiostat
Wuhan Corrtest Instruments Corp., Ltd.
Preview:
Product Description Corrtest Multichannel potentiostat/ galvanostat/EIS is a versatile instrument offering 8 slots. Multichannel potentiostat/ galvanostat model CS310X (Option D) is the 8-channel potentiostat. And all the slots are occupied with potentiostat boards. It equals that you can have 8 sets independent single-channel potentiostat/galvanostat in one chassis.EIS module (10μHz~1MHz) is equipped on all 8 channels for Option D. Each channel potential control range is ±10V, current control range ±1A, can meet experiment requirement for most researchers.Full floating module and electrical isolation design guarantee each channel is totally independent, which ensures accurate data and efficient simultaneous measurements.Multichannel potentiostat brings convenience to those who have many samples, and is an ideal device for studies of energy materials, battery study, metal corrosion etc. 8-channel potentiostat/galvanostatThere are 4 basic options for CS310X. Option A: 4-channel with EIS on one channel Option B: 4-channel, with EIS on all four channelsOption C: 8-channel, with EIS on one channel Option D: 8-channel, with EIS on all 8 channelsThe number of channel and EIS module can be customized.More channels can be added by potentiostat boards to be installed on current deviceEIS can be upgraded online. ModelCS310X OptionsOption AOption BOption COption DNumber of channels 4488Max. current on each channel±1A±1A±1A±1APotential range on each channel±10V±10V±10V±10VEIS (10μHz~1MHz)Included on 1 channel onlyIncluded on all 4 channelsIncluded on 1 channel onlyIncluded on all 8 channelsStandard supplyInstrument host CS310X-1 setCS studio6 software, Power cable - 1 piece, Ethernet cable - 1 pieceElectrode cable -8 pcs Dummy cell, Manual Instrument host CS310X-1 setCS studio6 software, Power cable - 1 piece, Ethernet cable - 1 pieceElectrode cable -16 pcs Dummy cell, Manual Application- Reaction mechanism of Electrosynthesis, electrodeposition (electroplating), anodic oxidation.- Electrochemical analysis, electro-catalysis, sensor; - New energy materials, advanced functional materials, photoelectronic materials;- Corrosion study of metals in water, concrete and soil etc;- Fast evaluation of corrosion inhibitor, water stabilizer, coating and cathodic protection efficiency.Specifications Specifications Number of channels with boards: 8Channel insulation resistance: >100MΩCommunication: EthernetLower-pass filter: covering 8-decadePotential control range: ±10VConstant current control range: ±1A on each channelPotential accuracy: 0.1%×full range±1mV Current accuracy: 0.1%×full rangePotential resolution:10μV(>100Hz), 3μV(<10Hz)Current resolution: 1pAPotential rise time: <1μs(<10mA), <10μs(<2A)Current range: 2nA ~1A, 10 rangesReference electrode input impedance: 1012Ω||20pFMaximum current output: 1ACompliance voltage: ±21VCurrent increment during scan: 1mA @1A/msCV and LSV scan rate: 0.001mV~10000V/sPotential increment during scan: 0.076mV@1V/msCA and CC pulse width: 0.0001~65000sDPV and NPV pulse width: 0.0001~1000sSWV frequency:0.001~100KHzCV minimum potential increment: 0.075mVAD data acquisition:16bit@1MHz,20bit @1kHzIMP frequency:10μHz~1MHzDA resolution:16bit, setup time:1μsCurrent and potential range: automatic Operating System requirements: Windows 10 /11Weight: 18 Kg Dimensions: 40*40*14cm Electrochemical Impedance Spectroscopy (EIS)Signal generatorFrequency range: 10μHz~1MHzAC signal amplitude: 1mV~2500mV Frequency accuracy: 0.005%Signal resolution: 0.1mV RMSDDS output impedance: 50ΩDC Bias: -10V~+10VWave distortion: <1%Waveform: sine wave, triangular wave, square waveScan mode: Logarithmic/linear, increase/decreaseSignal analyzerMaximum integral time:106 cycles or 105sMeasurement delay:0~105SMinimum integral time:10ms or the longest time of a cycleDC offset compensationPotential compensation range: -10V~+10VCurrent compensation range: -1A~+1ABandwidth adjustment: automatic and manual, 8-decade frequency range TechniquesStable polarizationOpen Circuit Potential (OCP)Potentiostatic (I-T curve)GalvanostaticPotentiodynamic (Tafel plot)Galvanodynamic (DGP)Sweep-Step Functions (SSF)Transient PolarizationMulti Potential StepsMulti Current StepsPotential Stair-Step (VSTEP)Galvanic Stair-Step (ISTEP)Chrono MethodChronopotentiometry (CP)Chronoamperametry (CA)Chronocaulometry (CC)VoltammetryLinear Sweep Voltammetry (LSV)Cylic Voltammetry (CV)Staircase Voltammetry (SCV)Square Wave Voltammetry (SWV)Differential Pulse Voltammetry (DPV)Normal Pulse Voltammetry (NPV)#Differential Normal Pulse Voltammetry (DNPV)AC Voltammetry (ACV)2nd harmonic AC Voltammetry (SHACV)Fourier Transform AC Voltammetry (FTACV)Stripping VoltammetryPotentiostatic StrippingLinear StrippingStaircase StrippingSquare Wave StrippingDifferential Pulse Voltammetry StrippingNormal Pulse Voltammetry StrippingDifferential Normal Pulse Voltammetry StrippingAmperometricDifferential Pulse Amperometry (DPA)Double Differential Pulse Amperometry (DDPA)Triple Pulse Amperometry (TPA)Integrated Pulse Amperometric Detection (IPAD) Electrochemical Impedance Spectroscopy (EIS)Potentiostatic EIS (Nyquist, Bode)Galvanostatic EISPotentiostatic EIS (Optional freq.)Galvanostatic EIS(Optional freq.)Mott-SchottkyPotentiostatic EIS vs. Time (Single freq.)Galvanostatic EIS vs. Time (Single freq.)Corrosion MeasurementsCyclic polarization curve (CPP)Linear polarization curve (LPR)Electrochemical Potentiokinetic Reactivation (EPR)Electrochemical Noise (EN)Zero resistance Ammeter (ZRA)Battery testBattery Charge and DischargeGalvanostatic Charge and Discharge (GCD)Potentiostatic Charging and Discharging(PCD)Potentiostatic Intermittent Titration Technique (PITT)Galvanostatic Intermittent Titration Technique (GITT)ExtensionsData LoggerElectrochemical Stripping/ DepositionBulk Eletrolysis with Coulometry (BE)Rs Measurement Simultaneous Measurements You can choose a same electrochemical technique in every channel. In each channel, the user can also choose different experiments. ApplicationsCorrosion Electrochemistry CS310X potentiostats/galvanostats support a variety of electrochemical techniques for corrosion, such as OCP recorder, potentiodynamic, EIS, cyclic polarization (CPP), LPR, hydrogen diffusion test, zero resistance ammeter (ZRA), electrochemical noise (ECN), etc. Due to their high input impedance(1013Ω), they are especially suitable for EIS measurement of high-impedance systems like coating, concrete, and pure water.High-impedance coating ageing test in salt spray testsPolarization curves of Ti-alloy& stainless steel in 3%NaCl solutionECN of low-carbon steel in 0.05mol/L Cl+0.1mol/L NaHCO3Energy & Battery Testing With versatile functions like linear sweep voltammetry (LSV), cyclic voltammetry (CV), galvanostatic charge/discharge (GCD), EIS(including potentiostatic and galvanostatic modes) with precise IR compensation, CS310X potentiostats are widely used in supercapacitor, Li-ion batteries, Li-S batteries, fuel cell, solar cell, solid-state batteries, flow batteries, and metal-air batteries, etc. CV of PPy supercapacitor in 0.5 mol/L H2SO4 solutionElectrocatalysisBased on CV and LSV techniques, CS potentiostats can carry out long-term tests for ORR, OER, HER, and CO2 reduction, which is crucial for evaluating catalyst stability. In addition, the CS2350M bi-potentiostat and multichannel potentiostat specialize in Faradaic efficiency synchronous measurement.CS310X potentiostats can measure the half-wave potential (ORR) and overpotential (HER, OER) of catalysts and calculate the power density and energy density of Redox peaks.LSV curves of various catalysts in alkaline solutionAnalytical ElectrochemistryCS310X potentiostats include comprehensive voltammetric methods such as NPV, DPV, DNPV, SWV, and ACV, which make them ideal for quantitative analysis of trace elements via the intrinsic Voltammetry stripping techniques.Stripping voltammetric curves in the solution dissolved with Pb2+, Cd2+, and Zn2+ ionsTechnical AdvantagesSwitchable floating and earthing mode All CS potentiostats/galvanostats can switch between the floating and earthing modes, and this strategy is beneficial for studying electrochemical systems in which the working electrodes are intrinsically ground, such as autoclaves, in-site concrete structures and multi-working electrodes requiring isolation, etc.High-bandwidth EIS with the help of built-in digital FRA and arbitrary signal generator, as well as the high input impedance (1013 W), the CS potentiostat is particularly suitable for EIS measurements of high-impedance systems (such as coating, membrane, concrete, etc.) Based on the DC bias compensation technique, CS potentiostats can conduct EIS tests under different charge/discharge states of batteries, making them suitable for ultra-low resistance systems, such as power batteries, fuel cells, water-splitting equipment, etc.Multiple electrode configurationsCS potentiostats support 2-, 3-, or 4-electrode configurations and can measure the galvanic current via built-in zero resistance ammeter circuits.Independent multiple channels For CS 310X multi-channel potentiostat, each channel is completely independent. It can be used for the electrochemistry measurements of multiple cells or multiple working electrodes in a cell.User-defined sequence testCS Studio 6.0 for Windows software supports user-defined sequence tests ("combination test"), which can facilitate automatic testing according to user-defined experiment sequences. Power boosterThrough CS2020B/CS2040B/CS2100B booster, the CS potentiostats can extend their output current up to ±20A/40A/100A, meeting the growing requirements in fuel cells, power batteries, electroplating and Software development kit (SDK)All CS potentiostats run under the control of CS Studio 6.0 for Windows (CSS 6.0). The CSS6.0 supports third-party languages, such as LabVIEW, C, C++, C#, VC, Python and others. Some API general interfaces and development examples can be supplied with the CS potentiostats. Through the SDK, customers can implement user-defined test methods. Real-time data saving CSS 6.0 saves experimental data timely, even if the experiment is accidentally interrupted by a power failure or computer shutdown. CSS 6.0 supports several data formats compatible with Originpro and Microsoft Excel. Versatile data analysis functionsCSS 6.0 provides robust functions, including various electrochemical measurements and data analysis. It can complete Tafel plot fitting, CV derivation, integration and peak height analysis, EIS equivalent circuit fitting, etc.3, 4 parameter polarisation curve fitting. EIS fitting Electrochemical noise spectrum analysis Pseudo-capacitance calculation GCD-specific capacitance, efficiency calculation Mott-Schottky analysis CV curve analysisActivation/re-passivation curve analysis
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.