IPDB › China Industry › Instruments & Meters › Analysis Instrument
ASTM_D6128-97 ASTM D6682-2008 Powder Flow Behavior Analyzer /Tester Powder Rheometer1
Analysis Instrument, Gas Analyzer, Powder Flow Behavior Analyzer, Powder Rheometer
Hunan Gonoava Instrument Co Ltd
Preview:
Product Description Product DescriptionASTM_D6128-97 ASTM D6682-2008 Powder Flow Behavior Analyzer /Tester Powder RheometerApplication Notes.1.Describe the flow behavior characterization by analyzing powder shear dynamic data, powder industry in processing, storage, transportation, silo often appear in the arch/rat hole structure.2. Friction between materials and between materials and solid walls.3. In the design of the hopper, the size of the discharge opening, the angle of inclination of the hopper wall and the pressure of the powder on the hopper wall, the design of the hopper is not reasonable will cause great difficulties to the production of 4. These behavioral characteristics affecting the fluidity of the powder through the measurement of the internal strength of the powder, the flow function, the friction function, the density, the function of time and other data to quantitatively analyze the above phenomena and statesASTM_D6128-97 ASTM D6682-2008 Powder Flow Behavior Analyzer /Tester Powder RheometerWorking Principle.Through the automatic control of the load applied to the shear cap; and act on the known speed of rotation of the ring-shaped shear box inside the sample, so as to realize the sample and the sample flow at different pressuresProduct ParametersVertical principal stress 0-100N; Resolution: 0.01kp Torque range 0-10 N.m Resolution: 0.01kp 3. Shear speed S 0.5 mm/min to 3 mm/min Operation PC software operation Measuring method Automatic Shear cover Serrated and flat cover, stainless steel Vacuuming system Hand-held automatic vacuuming Computer and Printer Customer's own or optional Sample preparation Scraper Power supply 220V+10% /50Hz Cutting box Aluminum alloy Communication interfaceUSB, RS-232 interface Temperature and humidity range8-40 oC Relative humidity in 35-80 Data management Data and chart report generation System management Device parameter setting and instrument self-testing Protective device Equipped with emergency stop control device Detailed Photos
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.