IPDB › China Industry › Instruments & Meters › Analysis Instrument
4-channel OEM SF6 Gas Leakage Detecting and Measuring System1
Analysis Instrument, Gas Analyzer, SF6 Gas Leakage Detecting, SF6 Gas Leakage
HV Hipot Electric Co., Ltd.
Preview:
Product Description Customized 4 Channel SF6 Gas Leakage Detecting System GDWGI. General informationGDWG SF6 Gas Leak Detecting and Measuring Systems high precision and sensitivity detecting system, which use NDIR technology principle and pumping cycle principle. It is used to detect few SF6 gas in the pipe quantitatively and qualitatively. Based on the design principle of infrared (detecting SF6 gas wavelength 10.2-10.6μm), the SF6 detection will be accurate.ApplicationSF6 detection and analysis of pipe typeSF6 detection and analysis of storage containerBenefits No radiation. No need to replace high pressure high pure argon gas regularly.No need to approach high pressure gas.No need to replace sensors regularly, cost-effective.Stable performance, low maintenance cost. No need to make linear calibration every year.No affect by moisture and environment pollution.Detection sensitivity is up to 0.1ppmv and 0.05ppmv.When serious leakage or the SF6 gas concentration is up to 100%, it will not be polluted or damaged.II. Features 3.5inch OLED display.One screen display SF6 gas concentration, temperature and humidity, battery indication, time and pump status.Friendly human machine interface.Fast measurement speed, up to10s to achieve stable data.Only response for SF6 gas, not for other gas.Make sure that no sensor poisoning occurs at any concentration.Small size, easy to carry, suitable for on-site working.Super-light aluminum with full shielding shell.Diaphragm pump suction sampling mode to ensure the tightness of the test gas path.III. SpecificationsMeasuring principle Non-dispersive infrared sensor (NDIR)Measuring range double path0-2000ppmv (resolution 0.1)0-50ppmv (resolution 0.01)limit range 0-100%Resolution 0.1ppmv and 0.01ppmvAccuracy ±2%FSRepeatability error ≤±1%Response time ≤10sRecovery time ≤15sLong time stability(span) ≤±20ppm, more than 1000 hoursLong time stability(zero) ≤±20ppm, more than 1000 hoursZero shift ≤±1%(F.S/year)Linear error ≤±1%Storage temperature -20 ~ +60oCOperation temperature -20 ~ +50oCWorking humidity 0-95% (no condensation)Sampling mode Diaphragm pump, flow up to 1L/min.Working voltage 220VAC±10%, 50Hz or Battery F750/8.4V.Air pressure 800-1150hPa
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.