IPDB › China Industry › Instruments & Meters › Analysis Instrument
Original Testo 320 Co Measurement (H2 compensated) Flue Gas Analyzer for Heating System Engineer No. 0563 3220752
Analysis Instrument, Gas Analyzer, Testo 320 Flue Gas Analyzer, Flue Gas Analyzer
Guangzhou Icecool Refrigeration Equipment Co., Ltd.
Preview:
Product Description Original Testo 320 CO measurement (H2 compensated) Flue gas analyzer for heating system engineer No.0563 322075Feature Six applications, one device: flue gas, flue draft, pressure, gas leak detection, CO ambient air and pressure difference measurementsIntegrated flue gas sensors with temperature sensor included; ultra-fine pressure sensors and a wide range of other sensors, ports and probes optionalRugged, high-quality design, high-resolution, multi-color display, self-explanatory menu guideTüV-tested according to EN 50379, Parts 1-3 and 1st BImSchVTemperature measurements at radiators; flue gas parameter and pressure measurements at burners; CO measurements in the ambient air: the testo 320 allows you to carry out all measurements in and around heating systems with only one measuring device.Product DescriptionThe testo 320 High Efficiency Flue Gas Analyzer is a reliable measurement tool for installation, testing and maintenance of heating systems. The high-quality, professional design and easy-to-use features of the testo 320 High-Efficiency Flue Gas Analyzer help you to perform all heating-related parameters measurements from one instrument. The rugged enclosure of the testo 320 High Efficiency Flue Gas Analyzer is specifically designed for everyday use in harsh environments.Well-structured measurement menus, designed according to different countries and built-in menu programs effectively simplify the operation. All readings are displayed on a high resolution color display that can be used in a variety of lighting situations. The testo 320 High Efficiency Flue Gas Analyzer also has a memory with 500 readings.Testo 320 Efficient Flue Gas Analyzer - Instrument FeaturesThe testo 320 high-efficiency flue gas analyzer is equipped with 1 flue gas sensor - one is an O2 sensor, and the other is a CO sensor. At the same time, there is a combustion air temperature sensor at the bottom of the instrument, and a thermocouple signal interface is integrated in the flue gas sampling probe interface. This helps you achieve simultaneous measurement of temperature, oxygen and carbon monoxide as well as other various parameters. The portable flue gas analyzer also automatically calculates relevant flue gas parameters such as CO2 value, boiler combustion efficiency, and flue gas loss.At the same time, there are plenty of different sensors and probes available for your choice. Including porous probes, flexible flue gas probes and precision pressure probes. This precise pressure probe helps you to measure the smoke pumping force and differential pressure synchronously with other parameters Testo 320 flue gas analyzer application Six applications. One instrument:(1)Smoke measurement(2)Smoke extraction measurement(3)Flue gas flow rate and static pressure measurement(4)Flammable gas leak detection(5)Environmental CO Measurement(6)Temperature difference measurementHelps you quickly and safely monitor and detect heating units, radiators, and burnersDelivery ScopeTesto 320 flue gas analyzer, O2 sensor and high quality instrument box. Choose you need model: (1) Testo 320 Set 1 (0563 322070) Flue gas analyzer (2) Testo 320 Set 2 (0563 322075) Flue gas analyzer DifferentMeasuring rangeAccuracy (± 1 digit)ResolutionAdjustmenttime t90Testo 320 Set 1 (0563 322070)CO measurement(withoutH2-compensation)0 to 4 000 ppm±20 ppm (0 to 400 ppm)±5 % of m.v. (401 to 2 000 ppm)±10 % of m.v. (2 001 to 4 000 ppm)1 ppm< 60 secTesto 320 Set 2 (0563 322075)CO measurement(H2-compensated)0 to 8 000 ppm±10 ppm or ±10 % of m.v. (0 to 200 ppm)±20 ppm or ±5 % of m.v. (201 to 2 000 ppm)±10 % of m.v. (2 001 to 8 000 ppm) 1 ppm< 40 secTesto 320 Set 1 (0563 322070)Option COlowmeasurement(H2-compensated)0 to 500 ppm±2 ppm (0 to 39.9 ppm)±5 % of m.v. (remaining meas. range) 0.1 ppm< 40 secTesto 320 Set 2 (0563 322075)Ambient COmeasurement(with CO probe)0 to 500 ppm±5 ppm (0 to 100 ppm)±5 % of m.v. (> 100 ppm)1 ppm Technical Data Measuring rangeAccuracy (± 1 digit)ResolutionAdjustmenttime t90Temperature -40 to +1 200 °C±0.5 °C (0 to +100.0 °C)±0.5 % of m.v. (remaining meas. range)±0.1 °C (-40 - +999.9 °C)1 °C (> +1 000 °C) Draughtmeasurement -9.99 to +40 hPa±0.02 hPa or ± 5 % of m.v. (-0.50 to +0.60 hPa)±0.03 hPa (+0.61 to +3.00 hPa)±1.5 % of m.v. (+3.01 to +40.0 hPa)0.01 hPawith fine draught option0.001 hPa Pressuremeasurement0 to +300 hPa±0.5 hPa (0.0 to +50.0 hPa)±1 % of m.v. (+50.1 to +100.0 hPa)±1.5 % of m.v. (remaining meas. range) 0.1 hPawith fine draught option0.01 hPa O2 measurement0 to 21 vol.%±0.2 vol.%0.1 vol.%< 20 secCO measurement(withoutH2-compensation)0 to 4 000 ppm±20 ppm (0 to 400 ppm)±5 % of m.v. (401 to 2 000 ppm)±10 % of m.v. (2 001 to 4 000 ppm)1 ppm< 60 secCO measurement(H2-compensated)0 to 8 000 ppm±10 ppm or ±10 % of m.v. (0 to 200 ppm)±20 ppm or ±5 % of m.v. (201 to 2 000 ppm)±10 % of m.v. (2 001 to 8 000 ppm) 1 ppm< 40 secEfficiency testing(Eta)0 to 120% 0.10% Flue gas loss0 to 99.9% 0.10% CO2 determinationdigital calculationfrom O2Display area0 to CO2 max±0.2 vol.%0.1 vol.%< 40 secOption COlowmeasurement(H2-compensated)0 to 500 ppm±2 ppm (0 to 39.9 ppm)±5 % of m.v. (remaining meas. range) 0.1 ppm< 40 secAmbient COmeasurement(with CO probe)0 to 500 ppm±5 ppm (0 to 100 ppm)±5 % of m.v. (> 100 ppm)1 ppm Gas leakmeasurement forcombustible gases(with gas leakdetector probe)Display area0 to 10 000 ppmCH4 / C3H8Signalvisual indication (LED)audible indication by buzzer Ambient CO2measurement (withambient CO2 probe)0 to 1 vol.%0 to 10 000 ppm± 50 ppm or ± 2 % of meas. val. (0 to 5 000 ppm)± 100 ppm or ± 3 % of meas. val.(5 001 to 10 000 ppm) < 2 secDifferentialpressure, flowvelocity andtemperature via finepressure probe±10 000 Pa0.15 to 3 m/smax. -40 to +1 200 °C(probe-dependent)±0.3 Pa (0 to 9.99 Pa) plus ±1 digit±3 % of m.v. (10 to 10 000 Pa) plus ±1 digit± 0.5 °C (-40 to +100 °C)±0.5 % of m.v. (remaining meas. range)plus probe inaccuracy0.1 m/s0.1 °CProduct Photos:FAQ1. Where is your company?we are located in Guangzhou, the capital city of Guangdong Province, near to Shenzhen, Foshan & Hong Kong, very convenient for shipping.2. How about the MOQ?1 unit is ok.3. Shipping methods and lead time?By Express: 5-7 working days to your door (DHL, UPS, TNT, FedEx...).By Air: 7-10 working days to your airport.By Sea: Pls advise your port of destination, the exact days will be confirmed by our forwarders, and the following lead time is for your reference.Europe and America (25 - 35 days), Asia (3-7 days), Australia ( 16-23 days). 4. What is the term of Payment?T/T, L/C,Western Union, Paypal; 30% T/T in advance,70% before delivery. 5. What are your main products?Compressor;Refrigeration gas;Refrigeration spare parts ;Cold room panels and equipments . 6. Packaging & Shipping:Packing: wooden pallet, wooden case or with outer carton, or as per customers' specific requirements.
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.