IPDB › China Industry › Instruments & Meters › Analysis Instrument
Karl Fischer Moisture Tester for Lithium Battery Industry1
Analysis Instrument, Moisture Meter, Battery Tester, Battery Tester Machine
XIAMEN TOB NEW ENERGY TECHNOLOGY CO., LTD.
Preview:
Product Description Karl Fischer Moisture Tester For Lithium Battery IndustryTOB-AKF-CH6 Karl Fischer moisture measurement equipment with moisture measurement module and feeding sample heating module function together, it's completely in accordance with the needs of lithium industry users, novel design, easy to use and maintenance, can fully cover the lithium battery industry from anode and cathode materials, electrode, separator and electrolyte; Moisture ranges from 1ppm to 100% of use requirements. Advantage:1. The equipment occupies less space and is more convenient to operate. For the lithium battery industry, especially for customers equipped with glove boxes, the all-in-one machine is more suitable.2. Automatic lifting puncture, effectively save manpower, improve analysis efficiency.3. Optimized some functions of the software to make the test more stable and convenient, and added functions such as user management and permissions to facilitate the management of the test process. FeatureKarl furnace and moisture meter integrated pioneered design in China, reasonable layout, less space occupation.Color touch screen, full digital keyboard, one button start, easy to operate, without professionals can easily work.HOGON intelligent detection technology: automatic balance, automatic detection, adapt to the environment drift automatically adjust detection accuracy.New electrolytic control ability, adapt to all kinds of electrolyte, high detection limit, moisture determination accuracy up to 0.01ug.With carrier gas flow electronic display, moisture content curve display and other functions, intuitive interface.Sample evaporator with constant temperature, Temperature programmed and other high precision temperature control mode, and with intelligent over temperature protection function.Automatic lifting puncture function plus rotary cover double injection mode, can be flexibly selected according to different use environment.Can edit, store, call a variety of different analysis method parameters, easy to adapt to different sample detection.Equipped with a variety of determination methods, and adapt to the gas, liquid, fixed samples and high and low water content of a variety of detection needs.Intelligent state monitoring, hardware intelligent protection, abnormal termination, timing stop and other capabilities, effectively extend the service life of the product. Measure MethodKarl FischerCoulomb method (Coulometry)Measure RangeH2O:3ug-199mg/0.01ug(H2O mass)Measurement resolution: 0.01ug(H2O mass)Measure repeatability>=99.7%(1000μgH2O)Applicable sample typeLiquid,solid,gasSample feeding methodDirect feeding, puncture feeding, change cover and purge feedingTemperature control rangeRT~285oC /0.1oC;3 level Temperature programmedHeating rate15oC/min(under 200oC)Measure durationAverage 50 seconds to 10 minutes (methods vary)Input gas sourceExternal dry air/nitrogen (99.99%)Carrier gas pressureInput limit: 0.6mpa, output: 0-0.4mpaFlow range0~100mL/minFlow accuracy1ml/minSample bottle specification10mlData outputRS232/USB,USB pin micro printerInstrument power300W;220V/50HzSize, weightL500*W250*H360(mm)Weight:11.5(kg) Application to Cathode Electrode, Electrolyte and Separator Karl Fischer Coulometry for Cathode Electrode Moisture Measure AbstractElectrode sheet is an important part of finished lithium battery, which is generally divided into cathode and anode electrode sheet. In this experiment, use TOB-AKF-CH6 all-in-one machine to measure the moisture content of cathode electrode sample.Experimental conditions: ambient temperature 25oC; Ambient humidity≤30%SampleCathode electrodeMeasure method1. Turn on the TOB-AKF-CH6 moisture tester and add an appropriate amount of Karl Fischer reagent to the titration tank to ensure that the reagent is between the maximum and minimum scale.2. Before opening the nitrogen cylinder, set and adjust the air volume and temperature.3. Wait for blank electrolysis balance test of the instrument.4. For sample testing, take appropriate amount of sample into the sample bottle, place it on the heating tank, connect the heating tracing tube, click start measurement, then sample, input relevant parameters, and wait for the measurement results Results No.Sample qty/gWater content/ugMeasure duration/ninResult/ppm10.6718203.95:00303.520.6383182.15:00285.330.6569187.65:00285.6 Karl Fischer Coulometry For Electrolyte Moisture Measure AbstractLithium battery electrolyte is the carrier of ion transport in the battery, which is generally composed of lithium salts and organic solvents. TOB-AKF-CH6 was used to measure the water content in the electrolyte sample.Experimental conditions: ambient temperature 25oC; Ambient humidity 35%SampleElectrolyteMeasure method1. Turn on the TOB-AKF-CH6 moisture tester and add an appropriate amount of Karl Fischer reagent to the titration tank to ensure that the reagent is between the maximum and minimum scale.2. Close the nitrogen cylinder3. Wait for blank electrolysis balance test of the instrument.4. For sample testing, take appropriate amount of sample into the sample bottle, place it on the heating tank, connect the heating tracing tube, click start measurement, then sample, input relevant parameters, and wait for the measurement results Results No.Sample qty/gWater content/ugMeasure duration/ninResult/ppm10.625.11:068.220.615.41:188.930.655.01:257.7 Karl Fischer Coulometry For Separator Moisture Measure AbstractIn the structure of lithium battery, separator is one of the key inner components. AKF-CH6 was used to measure moisture content in separator samples. Experimental conditions: ambient temperature 25oC; Ambient humidity 35%SampleSeparatorMeasure method1. Turn on the TOB-AKF-CH6 moisture tester and add an appropriate amount of Karl Fischer reagent to the titration tank to ensure that the reagent is between the maximum and minimum scale.2. Turn on the nitrogen cylinder,set gas flow,temperature3. Wait for blank electrolysis balance test of the instrument.4. For sample testing, take appropriate amount of sample into the sample bottle, place it on the heating tank, connect the heating tracing tube, click start measurement, then sample, input relevant parameters, and wait for the measurement results Results No.Sample qty/gWater content/ugMeasure duration/ninResult/ppm10.150523.44:11155.520.153227.84:14181.430.188739.34:15208.3
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.