IPDB › China Industry › Instruments & Meters › Analysis Instrument
Ls126A UV Light Meter UV Irradiance Meter for UV LED Light Source of Curing Machine with Ultra-Small Probe Sensor1
Analysis Instrument, Light Meter, UV Light Meter, UV Irradiance Meter
Shenzhen Taijin Precision Instrument Co., Ltd
Preview:
Product Description LS126A UV Light Meter UV Irradiance Meter for UV LED Light Source of Curing Machine with Ultra-small Probe SensorProduct ParametersDescriptions:LS126A UV light meter is primarily used for measuring the intensity and energy of UVA band UV LED light sources, commonly applied in industries such as curing and exposure. The digital uv meter features a wide spectral response, suitable for measuring various wavelengths between 365nm and 405nm. Additionally, its ultra-compact probe design, with a width of only 7.2mm, makes it ideal for measuring in narrow spaces where conventional probes may not easily fit. With data statistics function, the interface directly displays the maximum value, minimum value, average value, measurement time. Features:1. The uv index meter is primarily used for measuring the intensity and energy of UVA band UV LED light sources.2. The digital uv meter probe is designed with ultra-small size and can measure the narrowest width of 7.2mm.3. The uv meter can be acquired at high speed with 2048 samples per second and can accurately calculate UV energy.4. The uv tester meter interface directly displays the maximum value, minimum value, average value, measurement time and energy value.5. Suitable for 365nm, 375nm, 385nm, 395nm and other wavelengths of LED intensity and energy value detection.6. UV intensity measurementunits are switchable, with mW/cm2, W/cm2, and W/m2 selectable.7. Large measuring range, power value up to 20,000 mW/cm2.SpecificationsParameterValueSpectral response340nm-420nm, calibrated with 395nm UV LED light sourcePower measuring range0 - 20000 mW/cm2Resolution1 mW/cm2Energy measuring range0-9999999mJ/cm2Record time0-99999sAccuracy±10 %Sampling speed2048 times/secondOptional unitmW/cm2(default), W/cm2, W/m2Test hole diameter¢=3mmProbe dimension36mm ×7.2mm ×4.7mm(L*W*H)Host dimension170mm ×76mm×26mm (L*W*H)Probe wire length0.8mWeightAbout 232g (with battery)Display240*160 dot matrix LCDBattery4 AAA alkaline dry batteriesProduct DescriptionSuitable for UV LED curingThe curing light radiometer is primarily used for measuring the intensity and energy of UVA band UV LED light sources.7.2mm Ultra-small probeThe uv intensity meter probe is designed with ultra-small size and can measure the narrowest width of 7.2mm.Data statistics functionThe uv meter interface directly displays the maximum value, minimum value, average value, measurement time and energy value.Wide spectral rangeSuitable for 365nm, 375nm, 385nm, 395nm and other wavelengths of LED intensity and energy value detection.Multiple measurement unitsUV intensity measurement units are switchable, with mW/cm2, W/cm2, and W/m2 selectable.Large measuring rangePower value range up to 20,000 mW/cm2 with large measuring range.Packing ListNo.DescriptionQuantityUnit1LS126A UV light meter1Set2User manual1Pcs3Certificate/Warranty card1Pcs4Packing box dimension 34*29*9 cm(L*W*H)1PcsCompany ProfilePackaging & ShippingFAQ1. The difference between LS126A and LS125 UV light meters (UVALED-X0 and UVALED-X1 probe)?The functions of the LS126A UV light meter and the LS125 UV light meter host + UVALED-X0 or UVALED-X1 probe are basically the same. The probe width of LS126A is only 7.2mm, and the diameter of the test hole is 3mm, which is suitable for UV light source detection in a narrow space; the test hole diameter of the UVALED-X0 probe is 10mm, which is suitable for the detection of UV LED plane light sources; the test hole diameter of UVALED-X1 probe is 1mm, it's suitable for the detection of UV LED point light sources. 2. What is the difference between the LS126C UV light meter and other instruments?1. LS126C is equipped with a 1-meter test hook that meets the sterilization requirements of medical institutions as required by national standards.2. LS126C has Bluetooth function and mobile APP, which can monitor data wirelessly at a certain distance to avoid UV damage when viewing data on site. 3.126C can set the timed shutdown time. The measurement data is automatically saved when the machine is turned off. The next time the machine will display the last test result. Unattended measurements can be achieved.4. LS126C UV light meter comes with a real-time clock that traces the specific measurement time of the measurement results.For example, if you test 20 tubes continuously, you can check the specific test time of each tube. 5. LS126C has power graph display function and statistical function. The statistics function can record the real-time value, maximum value, minimum value, average value, measurement duration and test time during the test. The power graph can be used to analyze the luminous intensity after the lamp is lit.6. LS126C UV light meter is equipped with a USB communication port and dedicated PC software. Multiple sets of test data can be exported to an excel form and test reports can be generated for easy archival records. 3. How many values of the ultraviolet germicidal lamp used in hospitals would be up to standard?The "Technical Disinfection Technical Specifications" stipulates that the instrument is placed at a position of 1 m vertically under a 253.7 nm ultraviolet lamp. The irradiation intensity of the new ordinary 30W straight lamp is greater than 100 μW/cm2.The irradiation intensity of the ultraviolet lamp must be greater than 70μW/cm2. Different wattages of UV lamps, the country has different testing standards, 30W straight tube type is the most commonly used. 4. What is the difference of the test results between the LS126C UV light meter and the UV intensity indicator card? 1.The ultraviolet intensity indicator card is irradiated with the ultraviolet germicidal lamp for 1 minute. The color of the ultraviolet light sensitive color block is compared with the standard color block to determine the irradiation intensity of the light tube. The color contrast varies from person to person, especially in the case where the color of the photosensitive color block is not much different from that of the standard color block. Whether the intensity of the ultraviolet lamp is up to standard can only be qualitative, which is very difficult to quantitatively confirm. 2. LS126C UV light meter directly displays the radiation intensity value of the germicidal lamp tube. The measurement accuracy of the instrument is ensured to meet the national metrology institute test standard. 5. Do you offer OEM and ODM service? Yes. We can supply OEM and make customized design for any specific application. 6. How can we guarantee quality? Always a pre-production sample before mass production; Always final Inspection before shipment; 7. What can you buy from us? Colorimeter,Gloss meter,Coating thickness meter,window tint meter,UV meter, Leeb hardness tester, Ultrasonic thickness gauge. 8. What services can we provide? Accepted Delivery Terms: EXW,DAP;Accepted Payment Currency:USD,CNY; Accepted Payment Type: T/T,Western Union; Language Spoken: English, Chinese, Spanish, Japanese, Portuguese, German, French, Russian, Korean, Italian. 10. Does the instrument have a warranty?Guarantee period is 12 months, after the warranty, we also provide life-long paid or service.
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.