IPDB › China Industry › Instruments & Meters › Analysis Instrument
Sr2810b Digital Coating Thickness Meter1
Analysis Instrument, Other Analysis Instruments, Coating Thickness Meter, Gloss Meter
Shanghai Total Industrial Co., Ltd.
Preview:
Product Description SR2810F Micro Coating Thickness MeterFeatures:* Specially for the thickness measurement of coating on small workpiece.* Measuring methods: magnetic induction (F). * Two measurement mode: Single and Continuous (Notice: Continuous mode is convenient to measure the coating thickness of curved objects and tiny objects.)* Metric/imperial system selectable.* Manual or automatic shut down.* Auto memory of calibration value,and auto recognize the substrate.* Operation process have buzzing reminder,while no buzzing in continuous mode.* Use "USB data output" to connect with PC.* Provide "Bluetooth ? data output"choice.* Separate Type, measurements can be more flexibility.SR2810N Micro Coating Thickness MeterFeatures:* Specially for the thickness measurement of coating on small workpiece.* Measuring methods: eddy current (N).* Two measurement mode: Single and Continuous (Notice: Continuous mode is convenient to measure the coating thickness of curved objects and tiny objects.)* Metric/imperial system selectable.* Manual or automatic shut down.* Auto memory of calibration value,and auto recognize the substrate.* Operation process have buzzing reminder,while no buzzing in continuous mode.* Use "USB data output" to connect with PC.* Provide "Bluetooth data output" choice.* Separate Type, measurements can be more flexibility. SpecificationsModel SR2810FModel SR2810NOperating PrincipleMagnetic Induction (F) Eddy Current (NF)Measuring Range0~200um / 0~8milResolution0.1umMin. Radius Workpiececonvex 2mm / concave 4mmMin. Measuring Area2mmMin. Sample Thickness0.1mmAccuracy± 1~3%n or ± 2.5um Auto Power OffYesMetric / ImperialConvertibleBattery IndicatorLow Battery IndicatorOperating ConditionsTemp. 0~40°C, Humidity: 10~90%RHPower Supply4 x 1.5V AAA (UM-4) BatteryDimensions140 x 72 x 34mm ( 5.5 x 2.8 x 1.3inch )Weight215g (Not Including Batteries)Standard deliveryMain UnitMain UnitProbe (F Type)Probe (NF Type)Calibration Base Set (F Type) CTG-BSCalibration Base Set (NF Type) CTG-BSCalibration Foils CTG-CF (1set, 4pieces)Calibration Foils CTG-CF (1set, 4pieces)Carrying CaseCarrying CaseOperation ManualOperation ManualOptional accessories 1. USB, RS-232C data cable with software 2. Bluetooth data out put with software SR2810A Digital Coating Thickness Meter(F & NF type)Features:* Two measuring methods: magnetic induction (F) and eddy current (N)* Two measurement mode: Single and Continuous (Notice: Continuous mode is convenient to measure the coating thickness of curved objects and tiny objects.)* Metric/imperial system selectable.* Manual or automatic shut down.* Auto memory of calibration value, and auto recognize the substrate.* Operation process have buzzing reminder, while no buzzing in continuous mode.* Use "USB data output" to connect with PC. * Provide "Bluetooth ? data output" choice.* Separate Type can provide several type probe, measure can be more flexibility.Applications:The F probes measure the thickness of non-magnetic materials (e.g. paint, plastic, porcelain enamel, copper, zinc, aluminum, chrome etc.) on magnetic materials (e.g. iron, nickel etc.) . often used to measure the thickness of galvanizing layer, lacquer layer, porcelain enamel layer, phosphate layer, copper tile, aluminum tile, some alloy tile, paper etc. The N probes measure the thickness of non-magnetic coatings on non-magnetic metals. It is used on anodizing, varnish, paint, enamel, plastic coatings, powder, etc. applied to aluminum, brass, non-magnetic stainless steel, etc.SR2810B Digital Coating Thickness Meter(F & NF type)Features:* Can store the new data in 99 groups.* Two measuring methods: magnetic induction (F) and eddy current (N).* Two measurement mode: Single and Continuous (Notice: Continuous mode is convenient to measure the coating thickness of curved objects and tiny objects.)* Metric/imperial system selectable.* Manual or automatic shut down.* Auto memory of calibration value, and auto recognize the substrate.* Operation process have buzzing reminder, while no buzzing in continuous mode.* Use "USB data output" to connect with PC. * Provide "Bluetooth ? data output" choice.* Separate Type can provide several type probe, measure can be more flexibility.Applications:The F probes measure the thickness of non-magnetic materials (e.g. paint, plastic, porcelain enamel, copper, zinc, aluminum, chrome etc.) on magnetic materials (e.g. iron, nickel etc.) . often used to measure the thickness of galvanizing layer, lacquer layer, porcelain enamel layer, phosphate layer, copper tile, aluminum tile, some alloy tile, paper etc. The N probes measure the thickness of non-magnetic coatings on non-magnetic metals. It is used on anodizing, varnish, paint, enamel, plastic coatings, powder, etc. applied to aluminum, brass, non-magnetic stainless steel, etc.SpecificationsModelSR2810ASR2810BOperating principleMagnetic Induction & Eddy Current (F&NF)Magnetic Induction & Eddy Current (F&NF)Measuring range 0~2000 um / 0~80 milResolution0.1 um / 1 umMin. Radius Workpiece F Type: convex 1.5 mm / concave 25 mm, NF Type: convex 3 mm / concave 50 mmMin. Measuring Area6 mmMin. Sample Thickness0.3 mmAccuracy± 1~3%n or ± 2.5 umAuto Power OffYesMetric / ImperialConvertibleBattery IndicatorLow Battery IndicatorOperating Conditions Temp. 0~40 °C, Humidity: 10~90 %RHPower Supply4 * 1.5 V AAA (UM-4) BatteryDimensions140 * 72 * 34 mm ( 5.5 * 2.8 * 1.3 inch )Weight215g (Not Including Batteries)Standard deliveryMain Unit1Probe (F & NF 2 in 1)1Calibration Base Set1 F Type & 1 NF TypeCalibration Foils4Carrying Case1Operation Manual1Optional accessoriesUSB Cable & software, Bluetooth data output SR2807 Digital Coating Thickness Gauge(F & NF type)Features* It meets the standards of both ISO2178 and ISO-2360 as well as DIN, ASTM and BS. Suitable for the laboratory and for use in harsh field conditions.* The F probes measure the thickness of non-magnetic materials (e.g. paint, plastic, porcelain enamel, copper, zinc, aluminum, chrome etc.) on magnetic materials (e.g. iron, nickel etc.) . often used to measure the thickness of galvanizing layer, lacquer layer, porcelain enamel layer, phosphate layer, copper tile, aluminum tile, some alloy tile, paper etc.* The N probes measure the thickness of non-magnetic coatings on nonmagnetic metals. It is used on anodizing, varnish, paint, enamel, plastic coatings, powder, etc. applied to aluminum, brass, non-magnetic stainless steel, etc.* Automatic substrate recognition.* Manual or automatic shut down.* Two measurement mode: Single and Continuous* Wide measuring range and high resolution.* Metric/Imperial conversion.* Digital display gives exact reading with no guessing or errors.* Can communicate with PC computer for statistics and printing by the optional cable and the software for RS232C interface .SR2808 Digital Coating Thickness Gauge(F & NF type)Features* It meets the standards of both ISO2178 and ISO-2360 as well as DIN, ASTM and BS. Suitable for the laboratory and for use in harsh field conditions.* The F probes measure the thickness of non-magnetic materials (e.g. paint, plastic, porcelain enamel, copper, zinc, aluminum, chrome etc.) on magnetic materials (e.g. iron, nickel etc.) . often used to measure the thickness of galvanizing layer, lacquer layer, porcelain enamel layer, phosphate layer, copper tile, aluminum tile,some alloy tile, paper etc.* The N probes measure the thickness of non-magnetic coatings on nonmagneticmetals. It is used on anodizing, varnish, paint, enamel, plastic coatings, powder, etc. applied to aluminum, brass, non-magnetic stainless steel, etc.* Automatic substrate recognition.* Manual or automatic shut down.* Two measurement mode: Single and Continuous* Wide measuring range and high resolution.* Metric/Imperial conversion.* Digital display gives exact reading with no guessing or errors.* Can communicate with PC computer for statistics and printing by the optional cable and the software for RS232C interface . SpecificationsModelSR2807SR2808Operating principle(F& NF)(F & NF)Display4 digits, 10 mm LCD, backlitMeasuring range0-1250μm/0-50mil (other range may be specified)Resolution0.1 μm (0~99.9μm); 1 μm (over 100μm)Accuracy±1~5%n or 3.5 μm or 0.1mil (Whichever is the greater)Two measurement modeSingle and ContinuousMetric/ImperialconvertibleOperating conditionTemp. 0~50°C, Humidity <80%PC interfacewith RS-232C interfaceAuto switch off√Power supply2x1.5 AAA(UM-4) batteryDimensions & weight102x35x23 mm (4.0x1.4x0.9 inch)& about 40g (in-built probes) (not including batteries)Standard deliveryMain unit1F Type probe11NF Type probe11Substrate (Iron)11Substrate (Aluminum)11Calibration foil set1 set Carrying case1Instruction manual1Optional accessoriesRS-232C Cable & software, USB Cable & software, Bluetooth data output
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.