IPDB › China Industry › Instruments & Meters › Analysis Instrument
Westtune Xry-1c Oxygen Bomb Calorimeter 5mj/Kg~40mj/Kg ± 40j/G for Calorific Value of Petroleum Products ASTM D2430 Standard1
Analysis Instrument, Other Analysis Instruments, Oxygen Bomb Calorimeter, Calorimeter
Hangzhou West Tune Trading Co., Limited
Preview:
Product Description XRY-1C Automatic Oxygen Bomb CalorimeterSummaryThe instrument is designed and made as per the National Standard of People's Republic of China GB/T213-2008 and ASTM D240 Test Method for Calorific Value of coal, GB/T384-1988 Test Method for Calorific Value of Petroleum Products and Calibration Regulation of People's Republic of China JJG672-2001 Oxygen Bomb Calorimeter, as well as Shanghai enterprise standard Q//VCZK 10 " XRY Series Oxygen Bomb Calorimeter".Features:1. Adopting semiconductor refrigeration to decide the refrigerating capacity according to the calorific value,the instrument can automatically adjust water temperature and keep water in a relative constant temperature range,realize the continuously and long time test requirement,and make sure the test result is correct. 2. Using USB port,convenient to connect.One computer can control many sets of Oxygen Bomb Calorimeter. 3. With a electronic measuring cup itself,no need to weigh the water by manual,it can measure the water volume automatically,the repetitive error<0.4g 4. Automatically detecting the resistance of ignition filament,automatically checking the installing condition of ignition filament before test. 5. Standard pipeline design,vastly shortening the pipeline,and more reasonable pipeline design to ensure more precision of test results. 6. Adopting professional discharge water ports,more convenient and fast when the instrument drains away water or change the water. 7. The electronic balance with communication function to share the data by the internet.Specifications:Power supplyAC (220 ±10%)V, 50 HzTotal power consumption≤0.2kWMeasuring temperature range5oC~40oCTemperature resolution0.0001oCRSD(Relative standard deviation)≤0.1%Test time periodmain period:about 8minsMeasuring range5MJ/kg~40MJ/kgMeasuring error±40J/g (Benzoic acid) (National Standard for QC Check and Calibration)AccuracyBetter than GB/T213-2008 " The determination method of coal calorific value"Pressure endurance of oxygen bomb20 MPaSuitable environmentAmbient temp.:(15~35)oC Relative humidity: ≤85%Outline dimension650mm×450mm×450mm(L×W×H)Net weight55kgReal pictures for your reference:
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.