IPDB › China Industry › Instruments & Meters › Analysis Instrument
Digital Ecd Fpd Fid Tcd Npd Gas Detector Gas Chromatography Machine Transformer Oil Chromatograph Tester for Labs1
Analysis Instrument, Chromatography Spectroscopy Instrument, Gas Chromatograph with Tcd Fid Detector, Insulating Oil Gas Chromatograph
Biobase Meihua Trading Co., Ltd.
Preview:
Product Description BIOBASE Transformer Oil Advanced Gas chromatograph with Optional FID TCD ECD FPD NPD Product Description Product ParametersFeatures:1. 5.7-inch LCD display indicates temperature,time andgas flow.2. Self-test, power protection, keyboard lock, automatic ignition andantipower mutation interference function.3. Can connect with Internet,realize data transfer and program upgrade automatically.4. Equipped with a flame ionization detector (FID), and TCD, ECD, FPD, NPD are optional. Can install3 detectors at the same time.5. Can install packed column and capillary column at the same time6. Double column compensation function,which can effectively restrain baseline drift and theinfluence of background noise.7. Large capacity oven (300*280*180mm) can hold 2 pcs 0.32mm diametercapillary column (length: 80m).8. Better thermal insulation effect: when the temp. of oven,vaporizing chamber and detector reach 300oC, the max. temp. of outer chamber is 40oC.9. With chromatography workstation software to process data. ModelBK-GC7820OvenTemp. RangeRT~450oCTemp. Accuracy≤±0.1oCTemp. Program16-phaseMax. Temp. Heating Rate40oC/minDetectorHydrogen Flame Ionization Detector (FID)Detection limit:≤3×10^12g/s(Sample:n-hexadecane)Baseline drift:≤1x10^13A/30minLinear range:≥10^7ThermalConductivityDetector (TCD) (Optional)Sensitivity: >10000mv.ml/mg(Sample: n-hexadecane)Linear range:≥10^5Electron Capture Detector (ECD) (Optional)Detection limit:≤1×10-14g/ml(Sample:n-hexadecane δ-666)Linear range: ≥10^4Flame Photometric Detector (FPD) (Optional)Detection limit:≤2×10^11g/s(S ofthiophene)Detection limit:≤1×10^12g/s(P ofmethyl parathion)Linear range (S): ≥10^3 Linear range (P): ≥10^4 Nitrogen and Phosphorus Detector (NPD) (Optional)Detection limit:≤1×10^12g/s(Azobenzene)Detection limit:≤1×10^12g/s(Marla sulfur phosphorous)Linear range: ≥10^3Power SupplyAC110/220V±10%, 50/60HzStandard AccessoryFID detector, Chromatography workstation softwareOptional AccessorySample injection system, TCD, ECD, FPD and NPD detector, Chromatographic column.Package Size (W*D*H)800*570*650mmGross Weight75kgCompany Profile Mainly Products BIOBASE ExhibitionsShow Room Packaging & ShippingContact
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.