IPDB › China Industry › Instruments & Meters › Analysis Instrument
Zetron Lpc-M Online Particle Counter1
Analysis Instrument, Laser Particle Size Analyzer, Oil Particle Counter, Oil Counter
Beijing Zetron Technology Co., Ltd
Preview:
Product Description LPC-M online particle counterProduct DescriptionLPC-M online particle counter adopts the light resistance (shading) counting principle specified by the International Hydraulic Standards Committee, and is a device specially used for on-site online measurement of oil contamination level detection. It has the advantages of small size, light weight, fast detection speed, high accuracy, good repeatability, etc., and can work under high temperature and high pressure and other harsh conditions. It is suitable for all light-transmitting solvents such as engine oil, gear oil, transformer oil (i.e. insulating oil), hydraulic oil, lubricating oil, synthetic oil, water-based (water-based hydraulic oil, water glycol, etc.), alcohols, ketones, etc., and can be widely used in aerospace, petrochemical, transportation ports, steel metallurgy, automobile manufacturing and other fields.Product Feature Product FeaturesAdopting the principle of light blocking (shading) method and using high-precision laser sensor, it has small size, high precision and stable performance.Suitable for on-site online detection, real-time monitoring of particle contamination in the oil systemBuilt-in data analysis system, which can display the real data of particle size in each channel and automatically determine the sample gradeThe standard model can withstand a pressure of 100 kg directly, and a pressure reducing valve can be optionally used for ultra-high pressure online measurementIt has volume flushing and time flushing modes, which is convenient for users to use and maintain the equipmentBuilt-in ISO4406, NAS1638, SAE4059, GJB420A, GJB420B, Г OCT17216, GB/T14039 and other particle pollution level standardsBuilt-in calibration function, can be calibrated according to GB/T21540 , ISO4402, ISO11171, GB/T18854 and other standards, one test can give all built-in standard resultsAll standard alarm levels can be set independently to achieve pollution or cleanliness detectionWith RS232, RS485 and USB interfaces , it supports standard Modbus protocol and can be connected to computers, host computers, printers, PLC systems or other devices for data monitoring and processing.Large storage capacity, can be stored in the instrument or external storage deviceSturdy exterior structure, suitable for complex working environmentThe bottom-in, top-out mode helps to minimize the interference of online bubbles on test resultsContinuous testing is possible and the test time interval can be set arbitrarilyChinese and English dual systems, customers can switch freely, suitable for exportTouch screen or membrane button operation, can be switched freely, the instrument interface can freely control the switch of the remote printerOptional industrial control system equipment can be connected to achieve remote data monitoring, historical data, curve query (optional)Built-in moisture and temperature sensor module, can output four parameter information at the same time (optional) Product ParametersLight source semiconductor laserFlow rate range 5-500mL/minTest sample viscosity ≤650cStOnline detection pressure 0.1~10 Mpa (optional pressure reducing device with maximum pressure up to 42 Mpa)Particle size range 1~ 1000μmInterface USB interface, RS232 interface, RS485 interfaceData storage Provides 1,000 sets of data storage space and supports USB storageSensitivity 1μm or 4μm (c)Limit coincidence error 40,000 particles/mlCounting volume 1~999mlCounting accuracy ±0.5 pollution levelProtection level IP56 /IP67Temperature (optional) Collection range 1~100oC Measurement accuracy 1oCWater activity (optional) Collection range 1~100%RH; Measurement accuracy 1%RHMoisture content (optional) Collection range 1~360ppm; Measurement accuracy 1ppmTest time interval 1 second to 24 hoursDetection sample temperature 0~80oCWorking temperature -20~60oCPower supply AC 220V±10%, 50/60Hz or DC 9 - 36 VWeight 1kgVolume 115×85×60mm ApplicationOPC-L3 Oil Particle Counter is applicable to the detection of particle contamination of hydraulic oil, lubricating oil, anti-fuel oil, insulating oil and turbine oil. It can be widely used in aviation, aerospace, electric power, petroleum, chemical industry, transportation, port, metallurgy, machinery, automobile manufacturing and other fields.Company ProfileBeijing Zetron Technology Co., Ltd, formerly Beijing Senre Technology Co., Ltd was founded in 2011, located in Beijing with convenient transportation access. We have almost 10 years experience in the retail, import and export of gas detection and monitoring equipment. This experience has enabled us to form an organization based on knowledge and expertise and have allowed us to supply a range of gas detectors and monitors that are tailored to our customers needs and budgets.Our aim is to provide the best values products with high quality and style.To provide the new affordable and complete service for gas detection needs for the industrial, engineering and shipping market and our friendly staff are here to help with advice and prices. So far, we have customers/buyers from over 20 countries/regions like Bulgaria, Brazil, Canada, China, Colombia, Germany, Iraq, Japan, Philippines, Russian Federation, Singapore, Taiwan, Thailand, Uruguay, United States, Ukraine, Vietnam, etc.The list of countries still expanding.....We are committed to become the International Well Know Provider to provide similar or better alternative, original merchandises & service to meet customers' needs, requirements and solutions.Every customer is important to us and we strive to satisfy all our Customers needs and expectations.
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.