IPDB › China Industry › Instruments & Meters › Analysis Instrument
Conductivity Online Analyzer Soil Moisture pH Meter Sensor1
Analysis Instrument, pH Meter, pH Meter, ORP Meter
WEIHAI KUNKE FLOW INSTRUMENT CO., LTD.
Preview:
Product Description Wide range explosion-proof high PH meter with RS485 function Acidity meter (also known as pH meter) is an instrument used to measure the pH value of a solution, and the method for measuring the pH value of an acidity meter is a potentiometric method. In addition to measuring the acidity of the solution, it can also measure the electromotive force (mV) of the battery. It is mainly composed of three parts: reference electrode(calomel electrode), indicator electrode (glass electrode) and precision potentiometer. When measuring, the glass electrode is used as the indicating electrode, and the saturated calomel electrode (SCE) is used as the reference electrode to form a battery.Product Description SpecificationModeKK-PH160Display2.8-inch monochrome LCD display, resolution 128*64Dimensions96x96x112mmHole Size92x92mmWeight1.0kgMeasure rangepH:0.00-14.00pHORP:-1000~1000mV-2000~2000mV(customized)AccuracypH:±0.02pH;ORP:±lmVInput resistance>1012ΩTemp.CompNTC10K:-10~60oC accuracy :±0.3oC-10~130oCManu/AutoCurrent outputIsolated type, 4~20mA can be set to correspond to pH/ORP and temperatureMeasure rangeThe maximum load is 750Ω, the output accuracy is ±0.2%FSAlarm function2 channels, capacity AC250V/3A, normally openRelative humidity10~85%RH(10~85%RH)Working Temp.0~60°oCPower supply220VAC 5024VDC Company ProfileFounded in 2010, WEIHAI KUNKE FLOW INSTRUMENT is a high-tech company specialize in flow instrument R&D,production, sales and services of instruments.With advanced inspection instruments and equipment, professional talent team,perfect scientific management control system, WEIHAI KUNKE has been distinguished as a leading role in industry.We introduced advanced manufacturing technology from United States. We own a series of automation instruments withindependent intellectual property rights and advanced domestic automation instruments. Company has successivelyobtained International Quality System Certification of ISO 9001-2015, Environmental Management System Certificationof ISO14001-2015, Measurement Management System Certification of ISO10012-2003 and OHSAS18001-2007Occupational Health and Safety Management System Certification.credentialPacking & DeliveryFAQ1. Q:Same sample, two measurements of pH value is different?A:A change in temperature or a chemical reaction in the sample itself will cause a change in pH value. Therefore, the temperature should be kept as consistent as possible and chemical reactions should be avoided.2. Q:Why does the same sample, measured on two pH meters at the same time, have inconsistent readings?A:Due to the different correction conditions of the two pH meters (such as the correction done at different times), the measured values are different. Therefore, the pH meter should be corrected with the same buffer at the same time, and then measured at the same time.3. Q:PH meter measurement is unstable and takes a long time. Why is that? A:Because of aging electrodes. The response time of the electrode in the buffer can be tested, and if it is greater than 1 minute, the electrode needs to be activated or replaced with a new electrode. If the response time of the measurement buffer is short, but the measurement sample is unstable, it indicates that the electrode is not suitable for measuring the sample under test. Please select the appropriate electrode according to the electrode selection guide.4 .Q:Why has the buffer deteriorated and become unusable during its validity period?A:Buffer life refers to the shelf life of unopened use state. Once opened and used, the buffer is easy to deteriorate due to the action of various molds in the air. Note: The used buffer must not be poured back into the original bottle!5 .Q:How often should the electrodes be calibrated?A:The calibration frequency of the electrode depends on the specific situation of electrode use, maintenance, sample nature and measurement accuracy. Calibration is recommended once a day; No more than one calibration per week. If the electrode is replaced and not used for a long time, it must be calibrated before use.6. Q:The sample temperature is 10oC. Does the meter show the pH value at 10oC or 25oC?A:The pH meter shows the pH of the solution at the current temperature; If measure
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.