IPDB › China Industry › Instruments & Meters › Analysis Instrument
Aoda D50 Protein Determine Dumas Nitrogen Analyzer1
Analysis Instrument, Element Analyzer, Dumas Nitrogen Analyzer, Dumas Protein Analyzer
Henan Aoda Instrument Equipment Co.,Ltd
Preview:
Product Description Aoda D50 protein determine Dumas Nitrogen AnalyzerDumas Nitrogen Protein Analyzer determines the nitrogen/protein content of samples through combustion, purification, reduction, and thermal conductivity detection. It efficiently analyzes a single sample in 4 minutes without pretreatment and reacts in a nontoxic and harmless way to ensure safety and environmental friendliness. Product DescriptionConsiderable: a 1-disc 120-position autosampler (D200 only) is adopted to directly analyze a large number of samplesQuick: the fast cooling function helps the device reach the shutdown temperature in 30 minutesPremium: core pneumatic components of SMC? and mass flow controllers of Bronkhorst? retain the reliability for a long timeCost-effective: new consumables and efficient metal condenser dewatering technologies extend the service lifeTwo-stage combustion and oxidation: pure oxygen combustion in the primary combustion tube facilitates preliminary oxidation and digestion of a sample; the remaining part slides through the secondary combustion tube, together with the carrier gas, and is completely digested after being oxidized by the mixture of Pt catalyst and copper oxide;Three-stage dewatering: most of water is removed by an electronic condenser so that the desiccant can work; traces of water is removed by primary and secondary drying tubes;Efficient reduction: an efficient reduction agent reduces nitrogen oxides to nitrogen gas and absorbs excess oxygen;TCD detection: the thermal conductivity detector (TCD) can determine the nitrogen produced by reduction.ApplicationThe Dumas Nitrogen/Protein Analyzer is widely used to determine the total nitrogen content in diesel exhaust fluid, cereals (grain), seeds, meat, meat products, animal feed, dairy products, red wine, fertilizers and soil.AOAC uses the Dumas method as a standard method for the determination of crude protein content in grains and oilseeds, meat/meat products and animal feed.ISO uses the Dumas method for the quality assessment of cereals , pulses, ground cereal products, oilseeds and animal feed.AACC and ICC use this method to determine grain protein content.ISO and DIN (German Industrial Standards) also use this method for evaluating dairy products.AOAC and ISO/DIN use this method as the standard method for the determination of total nitrogen in fertilizers and soils.ISO, 2015, Natural raw rubber and natural latex Determination of nitrogen content by this method. Sampling System1.The 1-disc 120-position autosampler(D200 Only) can conduct a direct analysis of a large sample size2.SMC? pneumatic components can inject samples for 100,000 times, with low maintenance costs3.Users can add samples freely during preparation (either solid or liquid) to enhance experimental efficiency, without stopping the automatic analysis.Combustion Furnace System1.High-temperature, pure oxygen, and the two-stage combustion process ensure thorough oxidation and digestion2. An efficient metal condenser and two-stage desiccants can completely remove water.The desiccants can be reused for 2,000 times.3.New consumables can reduce nitrogen oxide, absorb excess oxygen, and prolong the service life. Both combustion and reduction tubes can be reused for 1,000 times.Pneumatic System1.A two-stage regulator eliminates the impact of external pressure fluctuations and combustion-induced pressure changes on the detector system to ensure stability.2.PTFE fittings and SMC? quick couplers allow for clear observation of contaminants and toolless maintenance.3.The combustion tube and joint of an original pneumatic connector support easy assembly and disassembly to eliminate air leakage caused by irreversible wear of ferrule compression fittingsSoftware FunctionWindows Chinese Version streamlines operation and improves efficiency. Click to configure parameters and conditions, and control the computer to gather, process, store and print out data.Wireless communication of balance data: an industrial wireless communication module automatically collects weight data, with the max distance of 100m. The data display window and voice authentication function can adjust value (D200 Only)Air leakage inspection: the gas path can be checked automatically or manually for the convenience of usersCustom lab report: report format, company name and logo, etc. can be customizedStandby/wake-up function: it reduces the on/off frequency and enhances the experimental efficiency. Carrier gas, power consumption and cost are lowered in standby modeIntelligent oxygenation function: the software adds oxygen subject to changes in conditions and samples to save reduction agents.Solution library: a solution library is built in and there' s no need to develop new approachesPeriodic maintenance reminder: time and cycle of consumable replacement are determined based on sample features, quantity, oxygen consumption, etc., and reminders will be issued timelySelf-diagnosis: if experimental conditions are not up to standard or not prepared, users can choose from 23 fault diagnosis methods to automatically raise a pop-up alarmData processing: experimental results can be easily reached by RSD and mean value calculationCalibration method: accurate experimental data are output by one point or multiple pointsAudit trail: the software has developed user permission hierarchy rules for easy traceability in accordance with FDA 21 CFR Part 11(D200 Only)LIMS: the software share data with the laboratory information management systemSpecificationD50 protein determine Dumas Nitrogen AnalyzerAnalysis efficiency3-4 min eachWeighing accuracy≤0.1mgDetection range0.1-500mg nitrogenDetection recovery rate≥99.5%Relative standard deviation (RSD)≤0.5% (150mg standard 10% nitrogen)LOD0.01mg nitrogenSample weightSolid ≤1g, liquid ≤1mLOperating systemWindows 7 and aboveSamplerD200:1 disc x 120 1 disc x 40 positions D50:1 disc x 60 positionsDetectorTCDTCD accuracy≤0.01oCCarrier gasCO2Furnace temperature1200oC (MAX)Carrier gas purity99.999%Oxygen purity99.999%Internal module communication modeRS-485 busPeripheral interfaceRS232, USBCorrection methodLinear or nonlinear calibration, custom calibration curveRated power2000WDimensions (L×W×H)735mm×560mm×560mmNet weight80kgPower supply220V AC ±10% 50HzComputerA laptop or a desktop operated with Windows 7 or above and equipped with USB or RS 232 interfaceTemperature5oC~30oCHumidity≤85%Packaging & ShippingFactory & WorkshopFAQQ : What products can you offer?A : We are a one-stop laboratory instrument supplier that can provide customers with products and solutions according to their needs.Q : How long is your usual delivery time?A : Our products are usually shipped out 5-7 days after receiving payment.Q : What transportation methods do you support?A : We support express delivery (DHL/FEDEX/UPS/TNT), trucks, trains, planes, and ships.Q : What trade methods can you accept?A : We support EXW, FCA, FOB, CFR, CPT etc
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.