IPDB › China Industry › Instruments & Meters › Analysis Instrument
Element Analyzer for Rapid Sulfur Identification in Various Samples with Carbon Sulfur Analyzer1
Analysis Instrument, Element Analyzer, Chemistry Analyzer, Testing Instrument
Shandong Wanlianda Instrument Co., Ltd.
Preview:
Product Description Company ProfileShandong Wanlianda Instrument Co., Ltd. has been focusing on analytical instruments for 30 years and become a leader in the field of domestic analytical instruments. Our high-frequency infrared carbonsulfur analyzer has 5 classical features: integrated design of highfrequency combustion furnace and infrared analyzer; two independent operating systems; reducing filter cleaning frequency significantly by using ultra-porous metal filters; more stable analytical gas flow by using gas mass flow controller; supporting wild measurement range including high-content carbon, low-content carbon, high-content sulfur and lowcontent sulfur. Product DescriptionMeasuring rangeC1:0.001-50%(expandable to 100%)C2:0.00001%-0.5%S1:0.00001%-60%(expandable to 100%)S2:0.00001%-5%Analysis accuracyCarbon RSD ≤0.4%Sulfur RSD ≤1.0%Sensitivity (reading)0.01ppmAnalysis time30-50sDetector5 sets (high carbon, low carbon, high sulfur, low sulfur, carbon monoxide)electron tubeceramicslight sourceNichrome wiremodulating motorSwitzerland (30,000 hours without failure)Absorption pool coating materialgold platedflow meterdigital qualityDetector sensitivity0.01ppmAccuracy Standard (RSD)C:≤0.4%S:≤1.0%carbon monoxide compensationhaveTemperature compensationhavepressure compensationhaveflow compensationhavePeak width compensationhaveAutomatic dust removalhavefilterMetal microporesPneumatic componentsJapan SMCway of communicationserial portCombustion power2.5KWWorking power220VAC, 50HZ. The induction furnace of CS-900 series high-frequency infrared carbon and sulfur analyzer with the function of automatic reverse purging dust removal. When it used with a dust extraction valve, it automatically removes a large amount of dust from combust, to make sure the accurate and repeatable analysis results, reducing manual cleaning time and increasing efficiency. High working efficiency, the dust removal power comes from the combustion exhaust gas, which truly realizes energy saving and environmental protection. Carbon and sulfur are one of the most widely distributed elements in nature. In the earth's crust, carbon and sulfur usually exist in the form of compound (such as carbonate, sulfate) and element (such as coal, sulfur). In the metal smelting process, no matter what smelting technology and craft is adopted, carbon and sulfur will inevitably enter the metal material and form a variety of compounds, which will have a certain impact on the properties of the metal. Therefore, in the entire smelting industry chain and downstream industry chain, the analysis of carbon and sulfur elements is necessary. The high frequency infrared carbon and sulfur analyzer is a fast carbon and sulfur analyzer, which analyzer is a advanced carbon and sulfur analyzer at present, and it is widely used in fields of metallurgy, machinery, scientific research, verification industries and etc.Based on the principle of high-frequency induction combustion, the carbon and sulfur elements contained in the sample are converted into CO2 and SO2. CO2 and SO2 have strong absorption bands at 4.26 μm and 7.4 μm respectively. By measuring the light intensity change after gas absorption, and analyze the percentage of CO2 and SO2 gas concentration, indirectly determine the percentage of carbon and sulfur in the measured sample. After circuit processing and analog-to-digital conversion, enter the computer for data processing, and finally print out the analysis results by a printer.Detailed PhotosInfrared Carbon/Sulfur Absorption DevicesIntegrated design of optoelectronic, exquisite and durable structure;Laser welds components, which ensure the tightness of gas system;Preamp adopts special integrated circuit, enabling reliability and stability reaching to level J standard. High-frequency Induction LoopSurface coated with special materials.Strong adhesion, antioxidant, no shedding.The efficiency of induction is highly improvedLengthen the lifetime of high frequency oscillating tube;The instrument can be used for a long time without power attenuation. High-frequency Oscillating Components Integrated design with high-voltage ceramic capacitors adopting level J products Digital Mass Flow ControllerDigital Mass Flow Controller adopts Honeywell sensors imported from America;Digital control provides accurate control and fast response;Digital Mass Flow Controller wouldn't be affected by temperature, pressure and any other external factors;The accuracy and stability of Digital Mass Flow Controller are better than the Variable Flow Meter.**Detailed explanation of installation requirements:**1. Instrument placement requirements: - The equipment should be placed on an insulated horizontal tabletop with a size of 240 cm. The tabletop needs to be able to accommodate three different instruments and a printer. - The tabletop width needs to be 90cm and the height 75cm, and the table must be more than 50cm away from the wall to ensure ventilation and safe separation. 2. Indoor environment requirements: - The room temperature should be controlled between 10 and 30 degrees Celsius, and the allowed temperature fluctuation does not exceed ±2 degrees Celsius. If this requirement cannot be met, air conditioning needs to be installed to maintain temperature stability. - The indoor humidity should be kept below 80%. It is recommended to use a dehumidifier to reduce the humidity and prevent the instrument from getting damp. 3. Power supply requirements: - The voltage needs to be stable at 220V, and the allowed fluctuation range is ±5%. If the fluctuation exceeds this range, a dedicated 5KVA voltage regulator must be used. - The equipment needs to have a dedicated ground wire, and the ground resistance should not be greater than 4 ohms to ensure safety. 4. Gas supply requirements: - The raw gas should be pure oxygen with a purity of 99.9% to ensure the accuracy of the experiment. - Nitrogen or oil-free compressed air can be used as motive gas to ensure that the gas is pure and contains no oil. 5. Working environment requirements: - The work area must be vibration-free to avoid interfering with the normal operation of the equipment, and dust-free to avoid contaminating the interior of the instrument. 6. Crucible handling requirements: - Heat the crucible to above 1200°C in a muffle furnace and incinerate it for at least four hours, then cool it naturally and store it in a desiccator within eight hours until ready for use.**Detailed description of acceptance test standards:**1. Repeatability index test: - Use the standard sample provided by Wanlianda Company with a carbon content of 0.5%-1.0% and a sulfur content of 0.045%-0.1% for seven consecutive measurements. - The relative standard deviation (RSD) should be less than or equal to 0.4% for carbon and less than or equal to 1.0% for sulfur to ensure the stability and reliability of the test results. 2. Accuracy test: - Carbon testing is divided into three concentration ranges: - Use a standard with a carbon content of 0.01%-0.1% for calibration and then test another sample within the same range. The measurement error must comply with the JJG395-2016 standard tolerance. - Use a standard with a carbon content of 0.1%-1% for calibration and then test another sample in the same range. Also ensure that the measurement error is within the allowable range. - Using standards with a carbon content of more than 1% for post-calibration testing still needs to meet the error standard. - The test of sulfur is also divided into two concentration intervals: - Use a standard with a sulfur content of 0.01%-0.1% for calibration and then test another sample within the same range to ensure that the measurement error meets the standard. - Use standard products with a sulfur content exceeding 0.1% for post-calibration testing, and the measurement error must also comply with the standard tolerance. 3. Acceptance confirmation: - After all standard tests meet the above requirements, the user should sign and stamp to confirm the completion of acceptance.Additional remarks:- Standards used during calibration should usually have a higher concentration than the sample being tested to ensure accuracy.- All standards used must be valid standards within the validity period and recognized by the department.**Detailed description of CS-901B high frequency infrared carbon and sulfur analyzer configuration and performance table:**I. Main configuration details: - A high-frequency infrared carbon and sulfur analyzer produced by Beijing Wanlianda Xinke. - A Swiss Mettler Toledo brand electronic balance. - A Lenovo brand computer. - A Lenovo brand laser printer. - A set of random accessories provided by Beijing Wanlianda Xinke. II. Detailed explanation of instrument analysis indicators: - Wide analysis range, the analysis range of carbon is extended from 0.001% to 50% (expandable to 100%), and the analysis range of sulfur is from 0.00001% to 5% (expandable). - Analysis time is fast, only 25 to 45 seconds to complete an analysis. III. Detailed explanation of main performance indicators: - The high-frequency combustion system has the characteristics of high-performance input power, efficient oscillation frequency and reliable imported pneumatic components. - The infrared analysis system adopts a special absorption cell, dual carbon cell, and single sulfur cell design to ensure a wide analysis range and high accuracy. - The electronic balance has high precision and a wide weighing range, which can meet the weighing needs of different samples. - The computer configuration is sufficient and the operating system is genuine, ensuring the stability and efficiency of the analysis software. - The system software processing system is powerful and easy to operate, with multiple compensation functions and linearization calibration options, ensuring the accuracy of analysis and flexibility of operation.Packaging & ShippingPackage Size600*1000*800mmPackage Gross Weight150kgCertificationsFAQ1. About the sample: How could I get a sample?Once receive your payment for samples and their express delivery and then send samples to you. The prices of the samples are the same as those on the pricelist. Express delivery charge depends on the quantity of the samples.2. About price list: can I get your price list?Yes, please tell us the products (with their code number) and order quantity, then we will offer the price by e-mail. And our price list will keep updated every month.3. About the shipment: what type of shipment will you use?We usually ship the products by sea and land transportation. 4. About payment: what terms of payment do you use?We accept TT (Telegraphic Transfer), Western Union as payment term for small order and L/C for larger order.5. About the MOQ: What is your minimum order qty?Our minimum order qty is 1pcs, we accept small order as trial order.6. About compensation: what is your company's compensation policy?We can compensate buyer's loss if our products have quality problem. For small qty problem products, we can replace with new products in next order. For larger qty problem products, we can accept returned problematic products, then we check them and replace them by good quality products.7. About sole-distributor: How can I be your sole-distributor?We have special policy for sole-distributor. Please contact our sales person to get related files.8. About OEM: could we place order by OEM style to produce our own brand products in China?Of course you can. Welcome to do OEM.Thanks for your interest
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.