IPDB › China Industry › Industrial Equipment & Components › Power & Generating Sets
Factory Price 1MW 2MW 3MW Cummins/Mtu/Mitsubishi/Perkins Engine Industrial Diesel Generator 1000kw 1500kw 1600kw 1800kw 2000kw 2500kVA 3000kVA Electric Start1
Power Generating Sets, Mtu Generator, 2000kw Generator
MECCA POWER CO., LTD.
Preview:
Product Description Company ProfileFor over a decade, MECCA POWER has been a leading global supplier of premium diesel generator sets (10KVA to 4000KVA), specializing in customized power solutions for critical large-scale projects. We expertly design and deliver reliable generators for demanding applications like Data Centers, Mining Operations, Oil & Gas Fields, Large Power Plants, and Major Construction sites.Leveraging deep industry expertise and partnerships with top engine manufacturers, we engineer robust, efficient, and tailored generator systems to ensure uninterrupted power continuity worldwide. Choose MECCA POWER for your mission-critical power needs and experience our commitment to quality, global support, and end-to-end project solutions.Product DescriptionMECCA offer MTU 500-3600KVA diesel generator sets Designed for reliability and efficiency, our generators are perfect for a wide range of applications, including:Data Centers,Construction,Mining Sites,Power Plants,Oil Gas,etc. Mtu generators provide robust and dependable energy solutions for remote and challenging environments,ensuring uninterrupted power supply to keep your operations running smoothly. At MECCA, we prioritize quality and innovation. Our MTU generators are engineered for durability and efficiency, ensuring they can handle demanding conditions while providing reliable performance.SpecificationPowered by MTU 50HZ 220-440V 500-3600KVA ModelLTPPRPEngineFuel Cons.Cyl.Disp.Gov.DimentionWeightKVA / KW KVA/KW ModelOriginL/H(100%)LL*W*H (MM)KGSMC660M660 528 600 48012V1600G10FIN117.012V21ECU3600*1604*21214529MC729M729 583 663 53012V1600G20FIN141.0 12V21ADEC3737*1899*21375249MC825M825 660 750 60012V1600G11FIN157.7 12V22.44ECU3630*2060*25255700MC880M880 704 800 64012V1600G21FIN167.6 12V22.44ECU3630*2060*25255700MC990M990 792 900 72012V1600G31FIN185.9 12V22.44ECU3630*2060*25255700MC880M880704 800640 12V2000G65CN184.012V23.9ADEC4100*1810*21306100MC1000M1000800 900720 16V2000G25CN210.016V31.8ADEC4495*2122*22957000MC1100M1100880 1000800 16V2000G65CN230.816V31.8ADEC4495*2122*22957150MC1250M12501000 1125900 18V2000G65CN264.516V31.8ADEC4840*1825*21658000MC1375M13751100 12501000 18V2000G26FCN261.118V35.8ADEC4840*1825*21658100MC1815M18151452 1650132012V4000G23FCN338.112V57.2ADEC6350*2150*250012500MC2021M20211617 1837.5147012V4000G63FCN373.112V57.2ADEC6350*2150*250013000MC2300M23001840 2087.5167016V4000G23FCN428.116V76.3ADEC7085*2250*250014500MC2475M24751980 2250180016V4000G63FCN465.516V76.3ADEC7085*2250*250015000MC2750M27502200 2500200020V4000G23FCN521.220V95.4ADEC7160*2555*293020500MC3080M30802464 2800224020V4000G63FCN567.520V95.4ADEC7160*2555*293021000MC3300M33002640 3000240020V4000G63LFCN610.520V95.4ADEC7160*2555*293021000MC500M500400 450360 10V1600G10FDE101.310V17.5ADEC3225*1485*20703850MC550M550440 500400 10V1600G20FDE110.910V17.5ADEC3225*1485*20703870MC660M660528 600480 12V1600G10FDE131.712V21ADEC3387*1531*21404890MC700M700560 644515 12V2000G25DE140.012V23.9ADEC4100*1810*21306100MC725M725580 660528 12V1600G20FDE144.912V21ADEC3387*1531*21403784MC1512M15121210 1375110012V4000G14RFDE307.612V57.2ADEC6150*2150*250012000MC1815M18151452 1650132012V4000G14FDE351.512V57.2ADEC6350*2150*250012500MC2020M20201616 1837.5147012V4000G24FDE398.212V57.2ADEC6350*2150*250013000MC2300M23001840 2087.5167016V4000G14FDE452.116V76.3ADEC7085*2250*250014500MC2500M25002000 2250180016V4000G24FDE491.616V76.3ADEC7085*2250*250015000MC2750M27502200 2500200020V4000G14FDE561.820V95.4ADEC7160*2555*293020500MC3080M30802464 2800224020V4000G24FDE611.620V95.4ADEC7160*2555*293021000MC3300M33002640 3000240020V4000G34FDE651.220V95.4ADEC7160*2555*293021000MC3600M36002880 3250260020V4000G44FDE653.020V95.4ADEC7160*2555*293021000Powered by MTU 60HZ 110-480V 625-4000KVA ModelLTPPRPEngineFuel Cons.Cyl.Disp.Gov.DimentionWeightKVA / KW KVA/KW ModelOriginL/H(100%)LL*W*H (MM)KGSMC875M87570080064012V2000G45CN179.612V23.9ADEC4100*1810*21306100MC1000M100080090072012V2000G85CN196.912V23.9ADEC4100*1810*21306900MC1125M1125900102582016V2000G45CN219.216V31.8ADEC4495*2122*22957000MC1250M12501000113891016V2000G85CN240.816V31.8ADEC4495*2122*22957150MC1500M150012001375110018V2000G85CN281.118V35.8ADEC4840*1825*21658200MC688M688 550 625 50012V1600G10SIN132.512V21ADEC3737*1899*21374890 MC756M756 605 688 55012V1600G20SIN140.0 12V21ADEC3737*1899*21374890 MC935M935 748 850 68012V1600G21SIN174.812V22.44ADEC4521*2135*2179 5829 MC1004M1004 803 913 73012V1600G31SIN186.712V22.44ADEC4521*2135*2179 5829 MC1121M1121 897 1019 81512V1600G41SIN207.512V22.44ADEC4521*2135*2179 5829 MC625M62550056345010V1600G20SDE114.110V17.5ADEC3225*1485*20703870MC688M68855062550012V1600G10SDE135.512V21ADEC3387*1531*21404890MC750M75060068855012V1600G20SDE145.212V21ADEC3387*1531*21404890MC2000M200016001819145512V4000G43DE348.212V57.2ADEC6150*2150*250012500MC2200M220017602000160012V4000G83DE405.712V57.2ADEC6350*2150*250013000MC2500M250020002250180016V4000G43DE469.816V76.3ADEC7085*2250*250014500MC2875M287523002625210016V4000G83DE535.516V76.3ADEC7085*2250*250015000MC3125M312525002875230020V4000G43DE598.820V95.4ADEC7160*2555*293020500MC3438M343827503125250020V4000G83DE651.720V95.4ADEC7160*2555*293021000MC4000M400032003637.5291020V4000G83LDE693.920V95.4ADEC7160*2555*293021000View more detailed spec. contact our team...Genset WorkshopFAQ1.Q: What is your MOQ of this item?A:1 Set2.Q: What are your payment terms?A:30% TT as deposit,70% TT before Shipment or 100% LC at sight3.Q:What's the warranty time of diesel generators?A:Global Warranty: 12months after delivery or 1000 running hours, whichever come first.4.Q:Can you accept the customized products?A:Yes, of course.We accept your specific order if you can provide us your special requirements or special samples5.Q:What's the delivery time ?A:20 to 35 days after receiving your payment in advance.6.Q:Do you offer OEM service?A: Yes7.Q:What is the power range do you have?A:Mecca Power assemble genset from 2 to 4000kva8.Q:What's your special compare to other manufacturer?A:We can delivery genset 1000units/month as engine and alternator OEM and Strategic partners. Especially for big quantity and big power projects, we support not only by solutions and tender documents, but also by fast delivery time and good price.Beside genset one-stop purchasing service to world-wide customers,CKD and SKD packing service are also available according to unique request.CKD:Complete Knock Down GeneratorGenerator completely knocked down into parts without assembling. All items from following are seperately packed without connection. SKD:Semi Knock Down GeneratorPartially assembled generator. Part of the following items you choose will be assembled.-----------------------------------------------------------------------------------------------MAITAINENCE---------------------------------------------------------------------------------------------General Troubleshooting This section lists the generating set for some common fault, the reasons for the failure and determines the method of fault. General operators can determine their own fault and note, maintenance it according to the brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation. Please remember the following suggestions before repairing: - Make sure that study the failure carefully before any operation. - Repair with the easiest way and most commonly used method. - Find the exact causes of failure and completely solve the fault. 1. Generator Sets Description of this section is for reference only. If the following failure occurs please contact the repairing agents. (Some models of control panel installed only parts of the following warning indicator light)IconIndicator LightReasonFault AnalysisLow oil pressurealarmLow oil pressurealarmWhen oil pressure does notreduce normally, the light is on.-General because of a lack of oil or lubricationsystem failure caused by (refueling or replacingthe oil filter)-When occurs this fault should automaticallyshutdown generator sets immediately.High watertemperaturealarmHigh watertemperaturealarmWhen the water temperaturehas risen to a level higher thanor equal to the sensor setting,the light is on.-General because of a lack of water or oilshortage, or overload.-When occurs this fault should automaticallyshutdown generator sets immediately.Low fuel levelalarmLow fuel levelalarmWhen a fuel level has beendetected by the sensor fitted tothe daily tank, the light is on.-General because of a lack of water or oilshortage, or overload.-When occurs this fault should automaticallyshutdown generator sets immediately.Battery chargerfault alarmBattery chargerfault alarmIf the charging system has fault,when engine running, the light isoff.-Battery charging system fault caused.-The light is on at the initial start, when thecharger reaches a certain speed, the light is off.-This failure will not lead to automatic shutdowngenerating units.Crank failurealarmCrank failurealarmWhen the generator set failedthree times (or six times) in arow starting, the light is on.-Oil supply system or re-start the system failurecaused.Overload orbreaker trippingalarmOverload orbreaker trippingalarmWhen overloading or Shortcircuit, the light is on. Trippingcircuit breakers cause generatorset load out.-In this fault, it need to load or unload some partsto eliminate short-circuit, and then re-close thecircuit breaker.Introduction of Maintenance grade(Interval) for the generator set A Level Maintenance Interval (Daily Maintenance)1. Check Daily Report of Genset .2. Check fuel level and coolant level. 3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or other damage.4. Check the Air filter. The air filter should be replaced when necessary .5. Release fuel tank and fuel filter's water and sediment.6. Check the water cooling filter.7. Check starting battery and electrolyte, add electrolyte when necessary. 8. Check the starter, check noisy defect.9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.B Level Maintenance Interval (Less than 400 hours)1. Repeatedly check A Level Daily Maintenance steps.2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice and real fact. 3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF Grade of American Petroleum Institute.4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or it can be replaced. The replacement must be according to the environment and real fact.5. Replace the cooling system and add coolant concentration.6. Clean the crankshaft and inlet, outlet air- filter net. C Level Maintenance Interval (2000-3000 hours), Please do as follows:1. Repeatedly check A and B Level Daily Maintenance steps.2. Remove the tap of valve, clean and wash oil dirt and sludge.3. Fasten snails from each part (including running parts and fixed parts)4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.6. Check and adjust valve clearance.7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; clean and wash water tank radiator fins, then check the using capability of thermostat.Current Repair (D Level Maintenance)(3000-4000 hours)1. Check valve, valve seat and other wearing, repair or change it when necessary.2. Check P pump, quality of injection, repair and adjust it when necessary.3. Check and adjust connecting rod and fastening twisting torque.4. Check and adjust valve clearance.5. Check the trip of injector.6. Check and adjust tension of fan and generating belt.7. Clean and wash accumulation of carbon in inlet pipes.8. Clean and wash the core of air cooler.9. Clean and wash the whole oil lubrication system.10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.Medium Repair (6000-8000 hours)1. Including the items of minor repair.2. Disassemble generator(except crankshaft)3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.4. Check fuel supplying system, adjust oil pump and injector.5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.Overhaul (9000-15000hours)1. Including the items of intermediate repair.2. Disassemble all the parts in the generator.3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake and exhaust valve, a whole set of tools for generator repair 4. Adjust oil pump, injector and replace pump core, injector5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.