Rpm95/Rpm95c_Power Quality Analyser_Network Analyzer_Panel Mounting Quality Analyser According IEC 61000-4-30 Class a1
Meter for ElectricityPower Quality AnalyserNetwork Analyzer
Romaz Technology Co., Ltd
Preview:
Product DescriptionProduct DescriptionRPM95/RPM95C panel mounting quality analyser according IEC 61000-4-30 class AThe power quality analyzer RPM95C is a high-end power quality analyzer, able to monitor and record the major power quality parameters. It provides an accurate measurement, voltage characteristics are monitoring according to EN61000-4-30:2015 Ed.3 Class A specification. RPM95C is designed to measurement of electrical parameters in LV and MV systems. It is built on 32bit DSP processor that it can provide sufficient processing capabilities for real-time measurement and calculation of all parameters. Continuous sampling of the voltage and current inputs at 66.5 KHz, guarantees the highest accuracy. At the same time it acts as event/fault recorder, capable to store a high number of voltage events and disturbances, frequency variations, inrush current. The RPM95/RPM95C is the ideal instrument for power quality monitoring according to EN50160 of the incoming energy supply side as well as on the consumer side in order to find and analysis the root cause of network problems.? True RMS measurements ? Measurements: VL-L, VL-N, I, In, Cos?, Pf, total Pf, Hz, W, ∑W, Va, ∑Va, Var, ∑Var, import Kwh, export Kwh, import Kvarh , export Kvarh , V THD , I-THD , 1-128th harmonic , system running hours , % voltage unbalance , % current unbalance , % system load ? 3 voltage and 4 current input (Measure or calculate the neutral current) ? Voltage Input: 0-690Vac, Current input: 1 or 5A CT selective ? Transients detection >25us, Detection of events >10ms ? Voltage flicker measurement, % system load ? Detects CT wiring errors ? Maximum, minimum and demand for U, I, P, Q, S in hours, days, months ? Multi-tariffe energy measurement (only for RPM95C) ? Real time clock with integrated backup battery ? 4 quadrants energy measurement support bi-directional power monitoring includes measurement on regenerative loads, also monthly energy calculation ? 2 pulse output and RS485 communication: Modbus RTU ? Waveforms capture and phase diagram for voltage, current ? Voltage and current sag/swell and transient event capture. ? Alarm event log ? Micro SD(support 32GB) for data logger? Built in 256M flash memory for event and transient memory ? Data recorded in standard excel file formats for further EN50160 analysis ? English, Chinese (traditional & simplied) ? Moduel function options (only one can be selected) ? 7 digital input +2 relay output(remote or alarm)(Standard) ? 7 digital input +2 analog output(4-20mA) for V1,V2,V3,V12,V23,V31,I1,I2,I3 (option) ? Ethernet (Modbus TCP), Web server +2 digital input +2 relay output (remote or alarm) (option) ? LoRa wireless (Private protocol) +2 digital input +2 relay output (remote or alarm)(option) ? RS-485 interface (Modbus RTU) +2 digital input +2 relay output (remote or alarm)(option) ? WIFI wireless+2 digital input +2 relay output(remote or alarm) (option)Optional? Four quadrants energy measurement and electric CO2 emissions accumulate ? Monthly energy and electric CO2 emissions calculation and recording ? Other languageOrderModelModelDescriptionN.W.(kg)G.W.(kg)Carton Size(WxHxD)(cm)RPM95RPM95C (Color)7 digital input +2 relay output(remote or alarm)(Standard)0.400.4511.5x9.5x10.5.E.EEthernet (Modbus TCP),web server +2 digital input +2 relay output0.400.4511.5x9.5x10.5.L.LLoRa (private protocol)+2 digital input +2 relay output(remote or alarm)0.400.4511.5x9.5x10.5.R.RRS-485(Modbus RTU)+2 digital input +2 relay output(remote or alarm)0.400.4511.5x9.5x10.5.A.A7 digital input +2 analog output(4-20mA)0.400.4511.5x9.5x10.5.D.DAuxiliary supply: 12...48VDC0.400.4511.5x9.5x10.5 Data logger and softwarePower monitoring software (PCMS) is designed for remote control and management of all Romaz instruments equipped with communication interface. Standard excel file formats gives the possibility to have a quick view and analysis on all stored data without any special software. PCMS is provided to perform statistical analysis and generate reports on recorded data according to EN50160 PQ standard.Technical dataCharacteristics RPM95/RPM95C Characteristics RPM95/RPM95C Auxiliary supplyHousingOperating voltage (Un)85···265Vac/110...330VdcSizeFlush mount 96*96mm The panel cut-size 92*92mmPower consumption4VADegree of protectionIP40(optional IP54) on front IP20 housing and terminalsFrequency45···65HzWeight400gVoltage measurement inputStandardMeasurement range10···690V AC L-LReference standardIEC61010-1; IEC61557-1; IEC61557-12; IEC61326-1; IEC62053-21; IEC62053-22; IEC62053-31; IEC60068-2-1; IEC60068-2-30; IEC60364-5-52; IEC61000-3-2; IEC61000-3-3; IEC61000-4-2; IEC61000-4-3; IEC61000-4-4; IEC61000-4-5; IEC61000-4-6; IEC61000-4-8; IEC61000-4-11; IEC61000-4-30Measuring modeTrue RMS* Measuring: VL-L, VL-N, I, In, Cos, Pf, Hz, W, ∑W, Va, ∑Va,Var, ∑Var, Kwh, Kvarh, THD-U, THD-I, 1-128th harmonics* Real time clock, system running hours* Built in 256M flash memory for event and transient memory* Four quadrants energy measurement and monthly energy calculation* 2 or 7 digital input and 2 relay output(remote or alarm) or analog output Measuring input impedance4MΩMethod of connectionsingle-phase,two-phase,three-phaseCurrent measurement inputMain incoming input (Direct)1A or 5AFeeders input0,05···5.5AMeasuring modeTrue RMSOverload capacity10A(Through the external current transformer)Self-consumption0,2VAAccuracy* Waveforms and phase diagram for voltage, current* Waveform recording and sag, swell and transient event capture. * Alarm event Log(over and under): VL-L, VL-N, I, In, ∑W, ∑Var, THD-U,THD-I * RS485 communication: Modbus RTU * Ethernet communication: Modbus TCP, Web server (depend on order) * Micro SD for data log (support 32GB)MeasuresVoltage±0.2%Current±0.2%Power±0.2%Power factor±0.2%Harmonics±1%Frequency±0.02%Active Energy ±Class 0.2SReactive Energy ±Class 0.5SInsulationInsulation voltage3kV for 1min,50HzDisplayDisplay type3.2" 240x160 pix LCD/3.5" 320x240 c olor TFT LCDAmbient conditionOpterating temperature-10···+55°CStorage temperature-25···+75°CRelative humidity95% max without condensingAltitudemax 2000m AMSLPeriod8GB16GB32GBInstallation & useInternal15 Minutes>15 Years>30 Years>60 YearsMechanical dimensionsProductionCompany Profile Romaz Technology Co., Ltd. is a subsidiary of LONPART (UK) Electronics Co., Ltd. Romaz is a engaged in the high-end protection relay,power quality analyzer, power meter, reactive power compensation products and data management system (SCADA) professional manufacturers. Our Romaz series covers most of its needs, ranging from simple low-cost panel meters for building management to high-end power quality analyzers for demanding smart grid applications. Our Romaz products have been used in more fields, including: Power plants, automobile manufacturing, large machinery manufacturing, food production, pharmaceutical factory, water treatment, commercial buildings, hospitals, subway and so on. Romaz has its own strong sales team, service team, product laboratory and product development team, who have rich experience in their respective fields. Studying new solutions and developing new products is critical to bringing the best technology to our customers. Our R & D team enables us to respond flexibly to market demand, provide customized modifications for existing products, and develop new solutions for special projects. Romaz works with a lot of high-end suppliers to provide customers with better products and services.https://romaz-world.en.made-in-china.com/product-list-1.html
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.