CIPDB › China Industry › Instruments & Meters › Meter for Liquid & Gas
China, Chinese Flow Measuring Electro Irrigation Water Electromagnetic Liquid Flowmeter1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Products Details Supplier Manufacturer price list catalog
Meter for Liquid GasElectromagnetic Flow MetreWater Flow Metre
Chongqing Hongxing Instrument Co., Ltd.
Preview:
Product Description Flow Measuring Electro Irrigation Water Electromagnetic Liquid FlowmeterProduct DescriptionOverviewThe smart flowmeter is a kind of high-accuracy and high-reliability flow meter to measure flow volume of conductive liquid or serum in a closed sealing pipeline. Widely used in electric power plant, oil and gas industry, chemical industry, coal, metallurgy, mining, paper making, water supply and drainage, food and other industries.Features Features There's no influence to accuracy with change of fluid density, viscosity, temperature, pressure and conductivity. Do not require much upstream and downstream straight run can be installed in relatively short meters.High definition LCD display with backlight and it's easy to read. Adopted PFA lining for high-pressure electromagnetic flow meter with high pressure, negative-pressure resistance, widely used in petrochemical, mineral industry.Generally used for process detection, and measurement for ore pulp, paper pulp and paste liquid. There's three inner calculators- positive gross, reverse gross and difference value to dual measuring system to display positive, reverse flow with varied kinds of output: current, pulse, digital communication and Hart. Ex-type instrument is used for relative Ex-proof environment.Product ParametersElectrode selection parameters Electrode MaterialApplicationSUS316 Applicable for water, sewage and low corrosive medium;Widely used in industries of petrol, chemistry, carbamide etc.Hastelloy B(HB)Having strong resistance to hydrochloric acid of any consistence which is below boiling point.Resistable against vitriol,phosphate, hydrofluoricacid, organic acid etc which are oxidable acid, alkali and non-oxidable salt.Hastelloy C(HC)Be resistant to oxidable acid such as nitric acid, mixed acid as well as oxidable salt such as Fe+++,Cu++ and sea waterTitanium(Ti)Applicable for seawater, and kinds of chloride, hypochlorite salt, oxidable acid (including fuming nitric acid), organic acid, alkali etc. Not resistant to a pure reducing acid (such as sulphuric acid, hydrochloric acid) corrosion. But if acid contains antioxidant (such as Fe+++,Cu++) is greatly reduce corrosionTantalum(Ta)Having strong resistance to corrosive mediums that is similar with glass. Almost applicable in all chemicals mediums except for oleum and alkaliPlatinum-iridiumAlmost be applicable in all chemical mediums except fortis, ammonium saltStainless Steel Coated Tungsten CarbideApplicable for non-corrosive and strong abrasive liquid Lining material selection parameters Lining materialFunction Application NeopreneExcellent elasticity, high breaking force and good wear resistanceCorrosion resistance to general low-concentration acid, alkali and salt medium, not corrosion resistance to oxidizing mediumWater, sewage Weak-abrasive mud, ore slurryPolyurethane rubberExcellent wear resistance (equivalent to 10 times that of natural rubber)Poor acid and alkali resistanceCan not be used in water mixed with organic solventsNeutral strong abrasive slurry, coal slurry, mud, etc.Fluorosilicone rubberExcellent elasticity, high breaking strength, high temperature resistanceWater temperature: ≤160oCPTFEThe material with the most stable chemical properties in plastics can withstand boiling hydrochloric acid, sulfuric acid and aqua regia, as well as concentrated alkali and various organic solvents, but it is not resistant to corrosion by chlorine difluoride, high-flow liquid fluorine, liquid gas, and odor.Poor wear resistanceConcentrated acid, alkali and other strong corrosive mediumF46Corrosive ability equals to PTFE Capable of low wearStrong negative pressure resistanceEquals to PTFE Can be used for low abrasive mediumPFACorrosive ability equals to PTFEStrong negative pressure resistance Applicable for negative pressure environment Range selection parameters Inner dia.(mm)Flow range(m3/h)Inner dia.(mm)Flow range(m3/h)DN100.3~1.6DN300300~1200DN150.8~3.0DN350400~1600DN201.2~5.0DN400500~2000DN252.0~8.0DN450600~2500DN323.0~12DN500800~3000DN405.0~20DN6001000~4000DN508.0~40DN7001600~5000DN6512~60DN8002000~6000DN8020~120DN9002000~8000DN10030~160DN10002500~10000DN12550~250DN12003000~12000DN15080~400DN14004000~16000DN200120~600DNH16005000~20000DN250200~800 Detailed Photos Our AdvantagesPackaging & ShippingCertificationsCompany ProfileFAQQ: The new magnetic flap liquid level gauge can't show liquid level?A: 1.check whether there is block in by pass pipe 2.check the the density of medium 3.check whether the float ball is stucked by float ball.Q: The longest length of magnetic flap liquide level gauge?A: the length is customized,but in order to be convenient for transport,if the length is over 6m,we recommendQ: If the float ball is installed at the wrong opposite direction,what's the influence?A: reading level will be higher than true level,usually higher by length of floatball-70mmQ: What's installation details of magnetic flap liquid level gauge ?A: 1.before installation,check specification with label plate. 2.There shouldn't magnetic field within 400mQ: There is problem in output signal 4--20mA?A: 1.Check working power supply 2.check wiring 3,check load resistance 4.verify measuring range,zero pointQ: what's specification we need to know before purchasing magnetic flap liquid level gauge?A: medium density,working temperature,working pressure,material,flange center to center distance,flange standard,whether need 4--20mA output signal;whether need level alarm.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...