CIPDB › China Industry › Instruments & Meters › Meter for Liquid & Gas
4800 Series Analog High Precision Thermal Gas Mass Flow Meter and Mass Flow Controller1
Meter for Liquid GasAnalog Mass Flow ControllerThermal Mass Flow Meter
Shenzhen Daxinda Machinery & Electric Equipment Co., Ltd
Preview:
Product Description APPENDIX 3SELECTION GUIDE 4800 Analog UP TO 50SLM MASS FLOW CONTROLLER/METERModel1.125" width48 SeriesStandard model 00 Product Type Mass Flow Controller FC Mass Flow Meter FM SealFKM R Metal M All Metal T CommunicationAnalog 9pin/±15v AN Analog 9pin/12-32v AV Control ValveNormally Closed C Normally Open(*1) O I/O Signal0 - 5VDC V 4 - 20mA I Fitting(*2)1/8" VCR E2V 1/4" VCR E4V 1/8" Swagelok Compatible E2S 1/4" Swagelok Compatible E4S 3/8" Swagelok Compatible E6S 1/2" Swagelok Compatible E8S 1" Swagelok Compatible EGS 6mm LOK G6S 8mm LOK G8S 10mm LOK GXS IGS 1.125"C-SEAL IGC IGS 1.125"W-SEAL IGW GASGas N2 Full ScaleFlow Rate 100 SCCMEXAMPLE MFC:4800-FCRANCV-E4V-N2-100SCCM / MFM:4800-FMRANV-E4V-N2-100SCCM(*1) For customized models, please contact your sales representative.(*2) For more fitting options, please contact your sales representative.(*3) Flow rate is calibrated (N2 eqv.) at standard temperature and pressure. (Standard: 0 Deg C and 101kPa)(*4)More requirement of Electrolytic Polishing or Passivating , please contact your sales representative.(*5) Model of 4-20mA control could only be chosen with 12-32VDC.4800 Analog UP TO 50SLM MASS FLOW CONTROLLER/METERModel 4800Full Scale Range (N2 eqv.)2 SCCM - 50 SLMControl ValveNormally closed/Normally OpenFitting1/4"VCR or 1/4" Swagelok CompatibleSealFKM SealFKMMetal SealNiResponse Time≤0.8 secAccuracy≤± 1% F.S.Linearity≤±0.5% F.S.(≥30SLM: ≤1%)Repeatability≤±0.1% F.S.Operating Differential Pressure2 SCCM - 5 SLM0.05 - 0.28 MPa6 SLM - 50 SLM0.1 - 0.28 MPaLeak IntegrityFKM SealMax 1x10-9Pa.m3/sec (He)Metal SealMax 1x10-11Pa.m3/sec (He)Control Range2-100% F.S.Max operating Pressure0.48 MPaProof Pressure1 MPaCommunication TypeDC 0-5V / 4-20mAPower Supply±15VDC+15VDC ±2% 25mA-15VDC ±2% 180mA+12VDC - +32VDC+12VDC 500mA - +32VDC 180mAOutput SignalDC 0-5V / 4-20mAPower Consumption±15VDC3.1W+12VDC - +32VDC6WOperation Temperature5-45 Deg CMaterialFKM SealSUS316L, FKM, PTFE, Electromagnetic stainless steelMetal SealSUS316L, Ni, PTFE, Electromagnetic stainless steelAll Metal SealSUS316L, Ni, Electromagnetic stainless steelSurface FinishFKM Seal≤5RAMetal SealTC,≤5RAWeightappr. 0.8 KG4800 Analog UP TO 150SLM MASS FLOW CONTROLLER/METERModel 4800Full Scale Range (N2 eqv.)50 SLM - 150 SLMControl ValveNormally closed/Normally OpenFitting3/8"VCR or 1/2" Swagelok CompatibleSealFKM SealFKMMetal SealNiResponse Time≤2 secAccuracy≤± 1.5% F.S.Linearity≤±0.5% F.S.Repeatability≤±0.2% F.S.Operating Differential Pressure0.15 - 0.28 MPaLeak IntegrityFKM SealMax 1x10-9Pa.m3/sec (He)Metal SealMax 1x10-11Pa.m3/sec (He)Control Range2-100% F.S.Max operating Pressure0.49 MPaProof Pressure1 MPaCommunication TypeDC 0-5V / 4-20mAPower Supply±15VDC+15VDC ±2% 25mA-15VDC ±2% 180mA+12VDC - +32VDC+12VDC 500mA - +32VDC 180mAOutput SignalDC 0-5V / 4-20mAPower Consumption±15VDC3.1W+12VDC - +32VDC6WOperation Temperature5-45 Deg CMaterialFKM SealSUS316L, FKM, PTFE, Electromagnetic stainless steelMetal SealSUS316L, Ni, PTFE, Electromagnetic stainless steelAll Metal SealSUS316L, Ni, Electromagnetic stainless steelSurface FinishFKM Seal≤5RAMetal SealTC,≤5RAWeightappr. 1.8 KG4800 Analog UP TO 300SLM MASS FLOW CONTROLLER/METER Model 4800Full Scale Range (N2 eqv.)100 SLM - 300 SLMControl ValveNormally closed/Normally OpenFitting3/8"VCR or 1/2" Swagelok CompatibleSealFKM SealFKMMetal SealNiResponse Time≤2 secAccuracy≤± 2% F.S.Linearity≤±0.5% F.S.Repeatability≤±0.2% F.S.Operating Differential Pressure100 SLM-150 SLM0.15 Mpa - 0.3 MPa150 SLM-200 SLM0.18 Mpa - 0.3 MPa200 SLM-300 SLM0.21 Mpa - 0.3 MPaLeak IntegrityFKM SealMax 1x10-9Pa.m3/sec (He)Metal SealMax 1x10-11Pa.m3/sec (He)Control Range2-100% F.S.Max operating Pressure0.49 MPaProof Pressure1 MPaCommunication TypeDC 0-5V / 4-20mAPower Supply±15VDC+15VDC ±2% 25mA-15VDC ±2% 180mA+12VDC - +32VDC+12VDC 500mA - +32VDC 180mAOutput SignalDC 0-5V / 4-20mAPower Consumption±15VDC3.1W+12VDC - +32VDC6WOperation Temperature5-45 Deg CMaterialFKM SealSUS316L,FKM, PTFE, Electromagnetic stainless steelMetal SealSUS316L, Ni, PTFE, Electromagnetic stainless steelAll Metal SealSUS316L, Ni, Electromagnetic stainless steelSurface FinishFKM Seal≤5RAMetal SealTC,≤5RAWeightappr. 1.93 KG 4800 Analog UP TO 2000SLM MASS FLOW CONTROLLER/METERModel 4800Full Scale Range (N2 eqv.)300 SLM - 2000 SLMControl ValveNormally closed/Normally OpenFitting3/4"VCR or 1" Swagelok CompatibleSealFKM SealFKMResponse Time≤2 secAccuracy≤± 2% F.S.Linearity≤±1% F.S.Repeatability≤±0.25% F.S.Operating Differential Pressure0.25 Mpa - 0.7 MPaLeak IntegrityFKM SealMax 1x10-9Pa.m3/sec (He)Control Range2-100% F.S.Max operating Pressure0.7 MPaProof Pressure3 MPaCommunication TypeDC 0-5V / 4-20mAPower Supply±15VDC+15VDC ±2% 25mA-15VDC ±2% 180mA+12VDC - +32VDC+12VDC 500mA - +32VDC 180mAOutput SignalDC 0-5V / 4-20mAPower Consumption±15VDC3.1W+12VDC - +32VDC6WOperation Temperature5-45 oCMaterialFKM SealSUS316L, FKM, PTFE, Electromagnetic stainless steelSurface FinishFKM Seal≤5RAWeightappr. 5.22 KG
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...