Acrel Amc100-Fak48 Multi Channels AC Precision Power Distribution Monitoring Device for Data Center RS4851
Meter for ElectricityAcrel Amc100-Fak48AC Multi Circuit
ACREL CO., LTD.
Preview:
Product Description AMC100 AC Precision Power Distribution Monitoring Device With the rapid development of data centers, the energy consumption of data centers has become more and more prominent, and the energy management and power supply and distribution design of data centers have become a hot issue. Efficient and reliable power distribution system scheme of data centers is an effective way to improve the power efficiency of data centers and reduce the energy consumption of equipment. In order to realize energy saving in data center, first of all, it is necessary to monitor each power load. However, there are many load loops in data center, and traditional measuring instruments cannot meet the requirements of cost, volume, installation, construction and other aspects. Therefore, it is necessary to adopt multi-loop monitoring device suitable for centralized monitoring requirements in data center. AMC100 series DC precision power distribution monitor is a measurement device designed specifically for power management of data center servers. The device design exquisite, can for A + B two into line and 192 road for electrical parameters, the input and output parameters of the switch state and the lightning protection device such as real-time monitoring, all alarm threshold measurement channels can be set in A separate, to qualify the limit event trigger system sound and light alarm, immediately on the volume in the traditional instrument, the height of the monitoring circuit integration. Product Description Technical Data ItemDataMeasurement parametersVoltage, current, power, energy, switching statusBus voltage rated48VDC,240VDC,336VDCCurrent outgoing loop rated5V (Hall sensor, external supply required ±12V)Measurement accuracyVoltage/current 0.5 level, power/energy level 1Auxiliary power supplyPowered by AMC100-ZD, DC 12-24V when used aloneCommunicationRS485/Modbus-RTUInstallation methodDIN35mm rail or baseplate mountingStorage temperature -25°C~ 70°CWorking temperature-15°C~55°CRelative humidity ≤ 93%Elevation≤2500mProtection levelIP20Pollution level2Security InsulationThe insulation resistance between all terminals and the conductive parts of the housing is not less than 100MΩAntistatic interferenceLevel 4Resistant to RF electromagnetic fieldradiationLevel 3Installation InstructionsPicture in Real SiteCertificationsFAQCompany Profile
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...