Send

Food Packaging Bag

Gift Box & Bag

Industrial Packaging Bag

Logistics Packaging

Machinery for Packaging Supplies

Non Woven Bag

Other Bags & Cases

Package & Conveyance

Package & Printing Service

Packaging Bags

Packaging Materials

Packing Bottle

Packing Machinery

Post-Press Equipment

Pre-Press Equipment

Printing Machinery

Printing Materials

Shopping Bags

Specialized Case & Box

Stencil

Tag & Sign

Tag Gun

Tool Packaging

Watch Box

CIPDBChina IndustryInstruments & MetersElectrical Control System



Delta Mitsubishi, Siemens, High-Speed Pulse Controller PLC Programmable Logic Controller Fx3u/Fx5u/Fx2n/Fx3g/Fx3ga S7-200/Dvp32es/Dvp-Eh/Ab1

« Previous Next »

Electrical Control SystemSiemensHigh-Speed Pulse Controller PLC Programmable Logic Controller Fx3u/Fx5u/Fx2n/Fx3g/Fx3ga S7-200/Dvp32es/Dvp-Eh/AbDelta PLCMitsubishi PLC

Shanghai UCANI Industrial Development Co., Ltd.

Preview:

Product Description MELSEC-F SeriesRich features and flexible system configuration in a compact size.The MELSEC-F series PLC incorporates power supply, CPU, and I/Os into a single compact unit.Meets the needs of a variety of user applications with options for I/O, analog, positioning, and open network expansion. Model series FX3U-16MR-/ES-AFX3U-16MT-/ES-AFX3U-128MT/ES-AFX5U-64MT/ESFX5U-32MT/DSFX5U-32MT/ESSFX5UJ-40MT/ESFX3U-32MR-/ES-AFX3U-32MT-/ES-AFX5U-32MR/ES FX5U-80MT/ESFX5U-64MT/DSFX5U-64MT/ESSFX5U-80MT/ESFX3U-48MR-/ES-AFX3U-48MT-/ES-AFX5U-64MR/ES  FX5UC-32MT/DFX5U-80MT/DSFX5U-80MT/ESSFX5UC-64MT/DFX3U-64MR-/ES-AFX3U-64MT-/ES-A  FX5U-80MR/ESFX5UC-64MT/DFX5U-32MR/DSFX5UJ-60MT/ES FX5U-80MR/ESFX3U-128MR-/ES-AFX3U-80MT-/ES-A FX5U-32MT/ES  FX5UC-96MT/DFX5U-64MR/DSFX5UJ-40MT/ESFX5UC-64MT/D High functionality model (FX3U/FX3UC)Faster, friendlier. Realize high expandability and high functionality.Fom high speed control to network support and even logging is possible.FX3 series flagship model FX3U and connector type FX3UC: 2 models are available. Standard model (FX3G/FX3GC)More advanced control for auotmation and networking.Equipped with functions required for standard controls, and fit for various purposes.Compact sized with the same performance, FX3GC is also available. Basic model (FX3S)Easy introduction to machine automation.Simple functions and economical price in one package.A basic micro PLC with expandability for analog and communication functions. FX PLC Main Unit A wide lineup in FX series offers you many choices to fit to your budget and application.You are sure to find a model that fulfills your needs.FX Series LineupFor high speed,high functionality,and expandability     Memory64,000 step RAM memory built-in. Flash memory cassette can also be mounted.Processing speedBasic instruction: 0.065 μs/instruction (LD instruction) Application instruction: 0.642 to 100 μs/instructionDeviceAuxiliary relay: 7,680 pts Timer: 512 pts Counter: 235 pts Data register: 8,000 ptsExtension register: 32,768 pts Extension file register (optional memory): 32,768 ptsApplication instructionList of supported application instructions For high speed,reduced wiring,reduced space       Memory64,000 step RAM memory built-in. Flash memory cassette can also be mounted.Processing speedBasic instruction: 0.065 μs/instruction (LD instruction) Application instruction: 0.642 to 100 μs/instructionDeviceAuxiliary relay: 7,680 pts Timer: 512 pts Counter: 235 pts Data register: 8,000 ptsExtension register: 32,768 pts Extension file register (optional memory): 32,768 ptsApplication instructionList of supported application instructions For communication,analog expansions,and up to 256 I/O control     Memory32,000 step EEPROM memory built-in. Battery-free and maintenance-free.Processing speedBasic instruction: 0.21μs/instruction (in standard mode) 0.42μs/instruction (in extension mode)Application instruction: 0.5 to 100 μs/instruction (in standard mode) 1.2 to 100 μs/instruction (in extension mode)DeviceAuxiliary relay: 7,680 pts Timer: 320 pts Counter: 235 pts Data register: 8,000 ptsExtension register: 24,000 pts Extension file register: 24,000 ptsApplication instructionList of supported application instructions*1: 14pt, 24pt models can only connect 1 board*2: 14pt, 24pt models have 2 independent axesFor reduced space andreduced wiring     Memory32,000 step EEPROM memory built-in. Battery-free and maintenance-free.Processing speedBasic instruction: 0.21 μs/instruction (in standard mode) 0.42 μs/instruction (in extension mode)Application instruction: 0.5 to 100 μs/instruction (in standard mode) 1.2 to 100 μs/instruction (in extension mode)DeviceAuxiliary relay: 7,680 pts Timer: 320 pts Counter: 235 pts Data register: 8,000 ptsExtension register: 24,000 pts Extension file register: 24,000 ptsApplication instructionList of supported application instructions For communication,analog expansions,and low cost     Memory16,000 step EEPROM memory built-in. Battery-free and maintenance-free.(Program capacity is 4,000 steps)Processing speedBasic instruction: 0.21 μs/instructionApplication instruction: 0.5 to 100μs/instructionDeviceAuxiliary relay: 1,536 pts Timer: 138 pts Counter: 67 pts Data register: 3,000 ptsApplication instructionList of supported application instructions Explanation of the icons Depending on control points, total 256 I/O extension devices can be connected.*Includes CC-Link remote I/O FX3U/FX3UC can count at high speed input frequency 100kHz (1-phase 6pts), 50kHz (2-phase 2pts), 10kHz (1-phase 2pts). Depending on control points, total 384 I/O extension devices can be connected.*Includes CC-Link remote I/O FX3S/FX3GC has 2 axes simple positioning function built into the main unit. Depending on the purpose, various special function blocks can be connected. FX3G/FX3U/FX3UChas 3 axes simple positioning built into the main unit.*FX3G 14 pt, 24 pt models have independent 2 axes. Function can be easily added by mounting a function expansion board to the main unit. I/O can be connected in connector format, reducing wiring effort. In FX3UC-32MT-LT, CC-Link/LT master functionality is built-in. 1 phase: 60 kHz x 4 pts/ 10 kHz x 2 pts    2 phase: 30 kHz x 2 pts/ 5 kHz 1 pt 1 phase: 60 kHz x 2 pts/ 10 kHz x 4 pts     2 phase: 30 kHz x 1 pt/ 5 kHz 1 pt In FX3S-30MR/ES-2AD, FX3S-30MT/ES-2AD, and FX3S-30MT/ESS-2AD, 2ch analog input (current input) function is built-in. Extension unitsPowered extension units are I/O extension devices with built-in power supply.Like with the main unit, various I/O devices and special devices can be connected after a powered extension unit.ModelTotal numberof pointsNumber of input/output pointsInput/output typeApplicable FX PLCInputOutputFX3SFX3GFX3UFX3GCFX3UCAC Power Type FX2N-32ER32 points16 points24 V DC(sink)16 pointsRelay×○○××FX2N-32ER-ES/UL24 V DC(sink/source)FX2N-32ES24 V DC(sink)TriacFX2N-32ET24 V DC(sink)Transistor(sink)FX2N-32ET-ESS/UL24 V DC(sink/source)Transistor(source) FX2N-48ER48 points24 points24 V DC(sink)24 pointsRelay×○○××FX2N-48ER-ES/ULDC24V(sink/source)FX2N-48ET24 V DC(sink)Transistor(sink)FX2N-48ET-ESS/UL24 V DC(sink/source)Transistor(source) FX2N-48ER-UA1/UL48 points24 points100 V AC24 pointsRelay×○○××DC Power Type FX2N-48ER-D48 points24 points24 V DC(sink)24 pointsRelay×○○××FX2N-48ER-DS24 V DC(sink/source)FX2N-48ET-D24 V DC(sink)Transistor(sink)FX2N-48ET-DSS24 V DC(sink/source)Transistor(source)Regarding connection cableA connection cable (length: 55mm), used to connect to the the right side of the device in front of the powered extension unit, is included with the powered extension unit. To extend the distance of the connection, please use the optional "extension cable".Function expansion boardThe expansion board is designed to add the input and output terminal whose points are small to FX3S or FX3G PLCs. The board can be built in the PLC.ModelTotalnumberofpointsNumber of input/output pointsInput/output typeApplicable FX PLCInputOutputFX3SFX3GFX3UFX3GCFX3UC FX3G-4EX-BD4points4points24 V DC(sink/source)--*1○Max.1 unit*2○Max.1 unit××× FX3G-2EYT-BD2points--2pointsTransistor(sink/source)*1○Max.1 unit*2○Max.1 unit×××*1: Supported by FX3S ver.1.10 and later.*2: Supported by FX3G ver.2.20 and later.Extension blocksExtension block is an I/O extension device that receives power from the main unit or powered extension unit.It can be connected in 8 point or 16 point units. The connectable number of points is determined by each main unit or powered extension unitModelTotal numberof pointsNumber of input/output pointsInput/output typeApplicable FX PLCInputOutputFX3SFX3GFX3UFX3GCFX3UCInput/output extension blocks FX2N-8ER8 points4 points(8 devicesare occupied.)24 V DC(sink)4 points(8 devicesare occupied.)Relay×○○*1*2○*1*2○FX2N-8ER-ES/ULDC24V(sink/source)FX2N-8EX8 points24 V DC(sink)--FX2N-8EX-ES/ULDC24V(sink/source)FX2N-8EX-UA1/UL100 V AC FX2N-16EX16 points16 points24 V DC(sink)×○○*1*2○*1*2○FX2N-16EX-ES/UL24 V DC(sink/source)FX2N-16EX-CConnector input24 V DC(sink)FX2N-16EXL-CConnector input5 V DCOutput extension blocks FX2N-8EYR8 points--8 pointsRelay×○○*1*2○*1*2○FX2N-8EYR-ES/ULFX2N-8EYR-S-ES/ULRelay(8 points/common)FX2N-8EYTTransistor(sink)FX2N-8EYT-HFX2N-8EYT-ESS/ULTransistor(source) FX2N-16EYR16 points16 pointsRelay×○○*1*2○*1*2○FX2N-16EYR-ES/ULFX2N-16EYSTriacFX2N-16EYTTransistor(sink)FX2N-16EYT-ESS/ULTransistor(source)FX2N-16EYT-CConnector outputTransistor(sink)*1 :For connection to FX3GC or FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*2 :Depending on the model name of the main unit, I/O extension device connection may or may not be allowed. For details, refer to the manual of the main unit.Regarding connection cableA connection cable, used to connect to the right side of the device in front of the extension block, is included with the extension block.To extend the distance of the connection, please use the optional "extension cable (FX0N-30EC/FX0N-65EC)" and "connector conversion adapter (FX2N-CNV-BD)".Extension block for connector type main unit (FX3GC, FX3UC)These I/O extension devices can be directly connected to FX1NC, FX3GC, FX2NC, FX3UC PLCs.They can be compactly extended because connection cables are not needed.ModelTotal numberof pointsNumber of input/output pointsInput/output typeApplicable FX PLCInputOutputFX3SFX3GFX3UFX3GCFX3UCInput extension blocks FX2NC-16EX-TTerminal block input16 points16 points24 V DC(sink)--×××*○*○FX2NC-16EX-T-DSTerminal block inputDC24V(sink/source) FX2NC-16EXDC24V(sink)FX2NC-16EX-DSDC24V(sink/source)FX2NC-16EX-D/ULDC24V(sink) FX2NC-32EX32 points32 points24 V DC(sink)FX2NC-32EX-DSDC24V(sink/source)FX2NC-32EX-D/ULDC24V(sink)Output extension blocks FX2NC-16EYR-TTerminal block Output16 points--16 pointsRelay×××*○*○FX2NC-16EYR-T-DSTerminal block output FX2NC-16EYTTransistor(sink)FX2NC-16EYT-DSSTransistor(source)FX2NC-16EYT-D/ULTransistor(sink) FX2NC-32EYT32 points32 pointsTransistor(sink)FX2NC-32EYT-DSSTransistor(source)FX2NC-32EYT-D/ULTransistor(sink)Input/output extension blocks FX2NC-64ET64 points32 points24 V DC(sink)32 pointsTransistor(sink)×××*○*○*: Depending on the model name of the main unit, I/O extension device connection may or may not be allowed. For details, refer to the manual of the main uniAnalog expansion board (A/D conversion, D/A conversion)Model(Number of channels)Input specificationsApplicable FX PLCItemInput voltageInput currentFX3SFX3GFX3UFX3GCFX3UCFX3G-2AD-BD(Input 2 ch)Inputrange0 to 10 V DC(Input resistance 198.7 kΩ)4 to 20 mA DC(Input resistance 250 Ω)*3○Max.1 unit*1*2○Max.2 units×××Resolution2.5 mV(10 V/4000)8 μA{(20 - 4 mA)/2000}FX3G-1DA-BD(Output 1 ch)Outputrange0 to 10 V DC(External load resistance value2 kΩ to 1 MΩ)4 to 20 mA DC(External load resistance value500 Ω or less)*3○Max.1 unit*1*2○Max.2 units×××Resolution2.5 mV(10 V/4000)8 μA{(20 - 4 mA)/2000}*1: Supported by FX3G ver. 1.10 and later.*2: FX3G 14pt, 24pt models: 1 board. 40pt, 60pt models: 2 boards.*3: Function expansion board and FX3S-CNV-ADP cannot be used together.page topMixed Analog Input/Output (A/D conversion, D/A conversion)Model(Number of channels)Input/output specificationsApplicable FX PLCItemInput/output voltageInput/output currentFX3SFX3GFX3UFX3GCFX3UCFX3U-3A-ADP(Input 2 ch)(Output 1ch)Inputrange0 to 10 V DC(Input resistance198.7 kΩ)4 to 20 mA DC(Input resistance 250 Ω)*7○Max.1 unit*1*6○Max.2 units*2○Max.4 units○Max.2 units*3○Max.4 unitsOutputrange0 to 10 V DC(External load resistance value5 kΩ to 1 MΩ)4 to 20 mA DC(External load resistance value500 Ω or less)Resolution[Input voltage]2.5 mV (10 V/4000)[Output voltage]2.5 mV (10 V/4000)[Input current]5 μA (16 mA/3200)[Onput current]4 μA (16 mA/4000)FX2N-5A(Input 4 ch)(Output 1ch)Inputrange-100 to 100 mV DC-10 to 10 V DC(Input resistance 200 kΩ)-20 to 20 mA DC4 to 20 mA DC(Input resistance 250 Ω)××○Max.8 units×*4*5○Max.8 unitsOutputrange-10 to 10 V DC(External load resistance value2 kΩ to 1 MΩ)0 to 20 mA DC,4 to 20 mA DC(External load resistance value500 Ω or less)Resolution50 μV(at ±100 mV)312.5 μV(at ±10 V)1.25 μA,10 μA((depending onmode used))*1: Supported by FX3G ver.1.20 and later. For connection to FX3G, FX3G-CNV-ADP is required.*2: Supported by FX3U ver.2.61 and later. For connection to FX3U, function expansion board is required.*3: Supported by FX3UC ver.2.61 and later. When connecting to FX3UC-32MT-LT(-2), function expansion board is required.*4: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*5: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D, FX3UC-**MT/DSS, FX3UC-16MR/D(S)-T: 8 units.*6: FX3G 14 pt, 24 pt models: 1 board. 40 pt, 60 pt models: 2 boards.*7: For connection to FX3S, FX3S-CNV-ADP is required.page topAnalog Input (A/D conversion)Model(Number of channels)Input specificationsApplicable FX PLCItemInput voltageInput currentFX3SFX3GFX3UFX3GCFX3UCFX3S-30MR/ES-2ADFX3S-30MT/ES-2ADFX3S-30MT/ESS-2AD(Input 2ch)Inputrange0 to 10 V DC(Input resistance 115.7 kΩ)------Resolution10 mV(10 V/1000)-FX2N-2AD(Input 2 ch)Inputrange0 to 10 V DC,0 to 5 V DC(Input resistance 200 kΩ)The input characteristic is the same for each channel.4 to 20 mA DC(Input resistance 250 Ω)The input characteristic is the same for each channel.××○Max.8 units×*1*2○Max.8 unitsResolution2.5 mV(10 V × 1/4000)1.25 mV(5 V × 1/4000)4 μA((20 - 4 mA) × 1/4000)FX3U-4AD(Input 4ch)Inputrange-10 to 10 V DC(Input resistance 200 kΩ)-20 to 20 mA DC,4 to 20 mA(Input resistance 250 Ω)××○Max.8 units×*1*2○Max.8 unitsResolution0.32 mV(20 V × 1/64000)1.25 μA(40 mA × 1/32000)FX3U-4AD-ADP(Input 4ch)Inputrange0 to 10 V DC(Input resistance 194 kΩ)4 to 20 mA DC(Input resistance 250 Ω)*8○Max.1 unit*4*3○Max.2 units*5○Max.4 units○Max.2 units*5*6○Max.4 unitsResolution2.5 mV(10 V/4000)10 μA(16 mA/1600)FX3UC-4AD(Input 4ch)Inputrange-10 to 10 V DC(Input resistance 200 kΩ)4 to 20 mA DC,-20 to 20 mA DC(Input resistance 250 Ω)××××*7*2○Max.8 unitsResolution0.32 mV(20 V × 1/64000)2.50 mV(20 V × 1/8000)1.25 μA(40 mA × 1/32000)5.0 μA(40 mA × 1/8000)FX2N-8AD(Input 8 ch)Inputrange-10 to 10 V DC(Input resistance 200 kΩ)4 to 20 mA DC-20 to 20 mA DC(Input resistance 250 Ω)××○Max.8 units×*1*2○Max.8 unitsResolution0.63 mV(20 V × 1/32000)2.50 mV(20 V × 1/8000)2.5 μA(40 mA × 1/16000)2 μA(16 mA × 1/8000)5.0 μA(40 mA × 1/8000)4 μA(16 mA × 1/4000)*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D, FX3UC-**MT/DSS, FX3UC-16MR/D(S)-T: 8 units.*3: FX3G 14pt, 24pt models: 1 board. 40pt, 60pt models: 2 boards.*4: When connecting to FX3G, FX3G-CNV-ADP is required.*5: When connecting to FX3U, function expansion board is required.*6: FX3UC-32MT-LT supported from version 1.20 or later.*7: FX3UC-32MT-LT supported from version 1.30 or later.*8: When connecting to FX3S, FX3S-CNV-ADP is required.page topAnalog Output (D/A conversion)Model(Number of channels)Output specificationsApplicable FX PLCItemOutput voltageOutput currentFX3SFX3GFX3UFX3GCFX3UCFX2N-2DA(Output 2 ch)Outputrange0 to 10 V DC,0 to 5 V DC(External load resistance value2 kΩ to 1 MΩ)4 to 20 mA DC(External load resistance value400 Ω or less)××○Max.8 units×*1*2○Max.8 unitsResolution2.5 mV(10 V × 1/4000)1.25 mV(5 V × 1/4000)4 μA((20 - 4) mA × 1/4000)FX3U-4DA(Output 4 ch)Outputrange-10 to 10 V DC(External load resistance value1 kΩ to 1 MΩ)0 to 20 mA DC4 to 20 mA DC(External load resistance value500 Ωor less)××○Max.8 units×*1*2○Max.8 unitsResolution0.32 mV(20 V × 1/64000)0.63 μA(20 mA × 1/32000)FX3U-4DA-ADP(Output 4 ch)Outputrange0 to 10 V DC(External load resistance value5 kΩ to 1 MΩ)4 to 20 mA DC(External load resistance value500 Ω or less)*7○Max.1 unit*3*4○Max.2 units*5○Max.4 units○Max.2 units*5*6○Max.4 unitsResolution2.5 mV(10 V/4000)4 μA(16 mA/4000)*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D, FX3UC-**MT/DSS, FX3UC-16MR/D(S)-T: 8 units.*3: FX3G 14 pt, 24 pt models: 1 board. 40 pt, 60 pt models: 2 boards.*4: When connecting to FX3G, FX3G-CNV-ADP is required.*5: When connecting to FX3U, FX3UC-32MT-LT(-2), function expansion board is required.*6: FX3UC-32MT-LT supported from version 1.20 or later.*7: When connecting to FX3S, FX3S-CNV-ADP is required.High speed counter block/adapterModel(Number of channels)TypeHighest responsefrequencyHardware comparisonoutput function2-phase counteredge count functionApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UCFX2N-1HC(1ch)1-phase1-countMax. 50 kHz○-××○Max.8 units×*2*3○Max.8 units1-phase2-countMax. 50 kHz2-phase2-count1 edge count:Max. 50 kHz2 edge count:Max. 25 kHz4 edge count:Max. 12.5 kHz○FX3U-2HC(2ch)1-phase1-countMax. 200 kHz○-××○Max.8 units×*2○Max.4 units1-phase2-countMax. 200 kHz2-phase2-count1 edge count:Max. 200 kHz2 edge count:Max. 100 kHz4 edge count:Max. 50 kHz○FX2NC-1HC(1ch)1-phase1-countMax. 50 kHz○-××××*3○Max.8 units1-phase2-countMax. 50 kHz2-phase2-count1 edge count:Max. 50 kHz2 edge count:Max. 25 kHz4 edge count:Max. 12.5 kHz○FX3U-4HSX-ADP(4ch)1-phase1-countMax. 200 kHz×○××*1○Max.2 units××1-phase2-countMax. 200 kHz2-phase2-count1 edge count:Max. 100 kHz4 edge count:Max. 100 kHz*1: When used together with analog or communication adapters, function expansion board is required.*2: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*3: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.page topBuilt-in high speed counter function (high speed input adapter function)FX3S Series PLCTypeCounter No.Highestresponsefrequency*Max. responsefrequency whenhigh speed processinginstruction is used*Supported high speed processing instructionsHighspeedcountermove2 phasecountermulti-countfunctionFX3U-4HSX-ADPmax. responsefrequency(FX3U only)Whenhigh speedcomparisonSET/RESETis usedWhenhigh speedbandcomparisonHSZis usedHighspeedcomparisonSETHighspeedcomparisonRESETHighspeedbandcomparisonCounterinterruptHighspeedtablecomparison1-phase1-countC235,C236,C241Max. 2pts:Max. 60 kHzoverall frequency60 kHz○○○×××-×C237 to C240,C242 to C245Max. 4pts:Max. 10 kHz1-phase2-countC246Max. 1pt:Max. 60 kHzC247,C248,C248(OP)C249,C250Max. 2pts:Max. 10 kHz2-phase2-countC251Max. 1pt:Max. 30 kHz×C252,C253,C253(OP)C254,C255Max. 2pts:Max. 5 kHz*: Regarding high speed counter reponse frequency, the overall frequency is limited. For details, please refer to the programming manual.FX3G, FX3GC Series PLCTypeCounter No.Highestresponsefrequency*Max. responsefrequency whenhigh speed processinginstruction is used*Supported high speed processing instructionsHighspeedcountermove2 phasecountermulti-countfunctionFX3U-4HSX-ADPmax. responsefrequency(FX3U only)Whenhigh speedcomparisonSET/RESETis usedWhenhigh speedbandcomparisonHSZis usedHighspeedcomparisonSETHighspeedcomparisonRESETHighspeedbandcomparisonCounterinterruptHighspeedtablecomparison1-phase1-countC235,C236,C238,C239,C241Max. 4pts:Max. 60 kHzoverallfrequency60 kHz○○○×××-×C237,C240,C242 to C245Max. 2pts:Max. 10 kHz1-phase2-countC246,C248(OP)Max. 2pts:Max. 60 kHzC247 to C250Max. 2pts:Max. 10 kHz2-phase2-countC251,C253(OP)Max. 2pts:Max. 30 kHz×C252 to C255,C254(OP)Max. 2pts:Max. 5 kHz*: Regarding high speed counter reponse frequency, the overall frequency is limited. For details, please refer to the programming manual.FX3U, FX3UC Series PLCTypeCounter No.Highestresponsefrequency*Max. responsefrequency whenhigh speed processinginstruction is used*Supported high speed processing instructionsHighspeedcountermove2 phasecountermulti-countfunctionFX3U-4HSX-ADPmax. responsefrequency(FX3U only)Whenhigh speedcomparisonSET/RESETis usedWhenhigh speedbandcomparisonHSZis usedHighspeedcomparisonSETHighspeedcomparisonRESETHighspeedbandcomparisonCounterinterruptHighspeedtablecomparison1-phase1-countC235 to C240Max. 6pts:Max. 100 kHz40 kHz40-(Numberof times ofuse of instruction)○○○○○○-200kHzC244(OP),C245(OP)Max. 2pts:Max. 10 kHz10 kHz200 kHzC241 to C245Max. 3pts:Max. 40 kHz40 kHz-1-phase2-countC246,C248(OP)Max. 2pts:Max. 100 kHz40 kHz200 kHzC247 to C250Max. 2pts:Max. 40 kHz40 kHz-2-phase2-countC251,C253Max. 2pts:Max. 50 kHz(1 edge count, 4 edge count)1 edge count40 kHz○100 kHz4 edge count10 kHz(40-Numberof times ofuse ofinstruction)÷4C252,C253(OP),C254,C255Max. 2pts:Max. 40 kHz1 edge count40 kHz40-(Numberof times of use of instruction)-4 edge count10 kHz(40-Numberof times ofuse ofinstruction)÷4*: Regarding high speed counter reponse frequency, the overall frequency is limited. For details, please refer to the programming manual.Variety of functionsBuilt-in high speed counter numbers and allocationMaximum frequency that the PLC can processHigh speed comparison results can be obtained by a simple program and no calculation delayFX3U, FX3U PLC counter mod High-speed output special adapterModelNumber ofcontrolled axisMaximumfrequencyApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX3U-2HSY-ADPIndependent two axes200kHz××*○Max.2 units××*: When used together with analog or communication adapters, function expansion board is requiredpage topPulse output blockModelNumber ofcontrolled axisMaximumfrequencyApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX3U-1PGIndependent one axis200kHz××*3○Max.8 units×*1*3○Max.6 units FX2N-10PGIndependent one axis1MHz(1 Hz to 1 MHzdifferential line driver output)××○Max.8 units×*1*2○Max.8 units*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.*3: FX3U, FX3UC supported from version 2.20 or later.page topSSCNETModelNumber ofcontrolled axisMaximumfrequencyApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX3U-20SSC-HTwo axes(Independent/Simultaneous)-××○Max.8 units×*1*2○Max.8 units*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.page topPositioning dedicated unitModelNumber ofcontrolled axisMaximumrequencyApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX2N-10GMIndependent one axis200kHz××○Max.8 units×*1*2○Max.8 units FX2N-20GMTwo axes(Independent/Simultaneous)200kHz*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.page topFor FX2N-10GM/FX2N-20GM positioning teaching panelModelProductE-20TP-SET0(with E-20TP-CAB0)FX2N-10GM, FX2N-20GME-20TP-E-SET0(with E-20TP-CAB0)page topAngle control unitModelNumber ofcontrolled axisMaximumfrequencyApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX2N-1RM-SET*1One axis720 divisions/rotation (0.5 degree)or 360 divisions/rotation (1 degree)××○Max.3 units×*2*3○Max.3 unitsFX2N-1RM-E-SET*1*1: FX2N-1RM-SET is a Japanese domestic only product. For use overseas, please select FX2N-1RM-E-SET, which supports overseas standards.*2: Extension cable cannot be used.*3: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.page topPLC built-in pulse output functions and positioning functionsItemsFX3SFX3G,FX3GCFX3U,FX3UCNumber of axisTwo axes[FX3G]Two axes (14/24 points)Three axes (40/60 points)[FX3GC]Two axesThree axesNumber of controlled axisIndependent two axes[FX3G]Independent two axes (14/24 points)Independent three axes (40/60 points)[FX3GC]Independent two axesIndependent three axesMaximum frequency100 kHz100 kHz100 kHzProgramming languagesSequence programsSequence programsSequence programsCompatible main unitTransistoroutput typemain unitTransistoroutput typemain unitTransistoroutput typemain unitPulseoutput instructionPulse Y Output(PLSY)○○○Acceleration/Deceleration SetupPulse Y Output(PLSR)○○○Pulse output typePulse train(Direction is controlledby PLC program)Pulse train(Direction is controlledby PLC program)Pulse train(Direction is controlledby PLC program)PositioninginstructionAbsolute Current Value Read([D]ABS)○○○Dog SearchZero Return(DSZR)○○○Zero Return(ZRN)○*1○*1○*1Variable Speed Pulse Output(PLSV)○○○Drive to Increment(DRVI)○○○Drive to Absolute(DRVA)○○○Interrupt Positioning(DVIT)××○Batch Data Positioning Mode([D]TBL)×○○*2Pulse output typePulse train + directionPulse train + directionPulse train + direction DetailsDetailsDetails*1: No DOG search function Decelerate when near point DOG turns ON, and stop when near point DOG turns OFF (Different from zero return operation with zero signal count)*2: FX3UC-32MT-LT supported from version 2.20 or later.page topOptional parts and spare partsServo motor connection cableModelLengthDescription E-GMH-200CAB2 m[MR-H series servo amplifer connection cable]Can direcly connect FX2N-10GM/FX2N-20GM and servo amplifer.I/O operation signal part has 20-pin connector for connection to Mtisubishi terminal block. E-GMJ-200CAB2 m[MR-J series servo amplifer connection cable]Can direcly connect FX2N-10GM/FX2N-20GM and servo amplifer.I/O operation signal part has 20-pin connector for connection to Mtisubishi terminal block. E-GMJ2-200CAB1A2 m[MR-J2, MR-J2-Super series servo amplifer connection cable]Can direcly connect FX2N-10GM/FX2N-20GM and servo amplifer. E-GMC-200CAB2 m[MR-C series servo amplifer connection cable]Can direcly connect FX2N-10GM/FX2N-20GM and servo amplifer.I/O operation signal part has 20-pin connector for connection to Mtisubishi terminal block. E-GM-200CAB2 m[General purpose connection cable]Has connector on both sides.Can connect to general purpose drive unit via Mitsubishi terminal block.Connector for self-manufactured I/O cable (an electric wire or a crimp tool is not enclosed.)ModelDescription FX2C-I/O-CON[Flat Cable Connector]AWG28 (0.1 mm2): A set of 10 pcsCrimp connector: FRC2-A020-3OS 1.27-pitch 20 coresCrimp tool: Separately arrange the tool manufactured by DDK Ltd.357J-4674D Main Unit357J-4664N Attachment FX2C-I/O-CON-S[Connector for bared wire]AWG22 (0.3 mm2): 5 setsHousing: HU-200S2-001Crimp contact: HU-411SCrimp tool: A product manufactured by DDK Ltd. is separately required.357J-5538FX2C-I/O-CON-SA[Connector for bared wire]AWG20 (0.5mm2): 5 setsHousing: HU-200S2-001Crimp contact: HU-411SACrimp tool: A product manufactured by DDK Ltd. is separately required.357J-13963Extension connection cableModelLengthDescription FX2N-GM-65EC65 cm[Connection extension cable between PLC and FX2N-10GM/FX2N-20GM]One cable cable can be used in a system.Standard connection cable (55mm) is included with FX2N-10GM/FX2N-20GM.F2-RS-5CAB5 m[Resolver extension cable for FX2N-1RM]Resolver can be extended up to 100m extension by linking multiple cables.Connection cable for peripheral devicesModelLengthDescription (1) E-20TP-CAB03 m[E-20TP connection cable]FX2N-10GM/FX2N-20GM (MINI DIN 8-pin) ? E-20TP (MINI DIN 8-pin)Cable length is different between (1) and (2).(1) E-20TP-CAB0 (3 m) is included with E-20TP-SET0.(2) FX-20P-CAB01.5 mSpare partsModelLengthDescriptionFX2N-GM-5EC55 mm[Connection cable between PLC and FX2N-10GM/20GM]One cable is included with FX2N-10GM/20GM. CC-LinkModelMaster stationfunctionRemote/slavefunctionDistanceApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX3U-16CCL-M*1CC-Linkmaster block(Master station)○×1,200 m maximum×○Max.1 unit*4○Max.1 unit*2○Max.1 unit*2*3○Max.1 unit FX2N-32CCLCC-LinkInterface block(Remote device station)×○1,200 m maximum×○○*2○*2○ FX3U-64CCLCC-LinkInterface block(Intelligentdevice station)×○1,200 m maximum×○Max.1 unit○Max.1 unit*2○Max.1 unit*2*3○Max.1 unit*1: The FX3U-16CCL-M, FX2N-16CCL-M cannot be used at the same time with the FX2N-32ASI-M.The FX3U-16CCL-M cannot be used at the same time with the FX2N-16CCL-M.FX3U-16CCL-M and FX2N-16CCL-M cannot be used together.[Remote I/O station]Maximum 8 stations can be connected (1 station occupies 32 I/O points of the PLC)[Total of remote device stations + intelligent device stations]Maximum 8 stations can be connected (However, the total number of RX/RY points is 256 or less)*2: When connecting to FX3GC,FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*3: FX3UC supported from version 2.20 or later.*4: FX3U supported from version 2.20 or later.page topCC-Link/LTModelMaster stationfunctionRemote/slavefunctionApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX2N-64CL-MCC-Link/LTmaster block○××○Max.8 units○Max.8 units*1○Max.5 units*1○Max.5 units FX3UC-32MT-LTBuilt-in CC-Link/LTmaster○×----- FX3UC-32MT-LT-2Built-in CC-Link/LTmaster○×-----*1: When connecting to FX3GC,FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.page topCC-Link/LT: Power AdapterDedicated Power SupplyModelApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC CL1PAD1Power Adapter×○○○○CL1PSU-2ADedicated Power Supply×○○○○page topEthernetModelApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX3U-ENET-L××*1○Max.1 unit×*1*2○Max.1 unit FX3U-ENET-ADP*7*8○Max.1 unit*3*5○Max.1 unit*4*6○Max.1 unit*3○Max.1 unit*4*6○Max.1 unit*1: FX3U,FX3UC supported from version 2.21 or later.*2: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*3: FX3G, FX3GC supported from version 2.20 or later.*4: FX3U, FX3UC supported from version 3.10 or later.*5: When connecting to FX3G, FX3G-CNV-ADP is required.*6: When connecting to FX3U or FX3UC-32MT-LT(-2), a function expansion board is required.*7: When connecting to FX3S, FX3S-CNV-ADP is required.*8: When connecting to FX3S, supported by FX3U-ENET-ADP Ver.1.20 or later.page topMODBUSModelApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX3U-232ADP-MBSpecial adapter forRS-232C communication*7○Max.1 unit*1*2*3○Max.2 units*4*5○Max.2 units*6○Max.2 units*4*5○Max.2 units FX3U-485ADP-MBSpecial adapter forRS-485 communication*7○Max.1 unit*1*2*3○Max.2 units*4*5○Max.2 units*6○Max.2 units*4*5○Max.2 units*1: FX3G 14pt, 24pt models: 1 unit. 40pt, 60pt models: 2 units.*2: When connecting to FX3G, FX3G-CNV-ADP is required.*3: FX3G supported from version 1.30 or later.*4: When connecting to FX3U,FX3UC-32MT-LT(-2), Function expansion board is required.*5: FX3U, FX3UC supported from version 2.40 or later.*6: FX3GC supported from version 1.40 or later.*7: When connecting to FX3S, FX3S-CNV-ADP is required.page topPROFIBUSModelApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX3U-64DP-MPROFIBUS-DPMaster block××*1○×*1*2*3○ FX3U-32DPPROFIBUS-DPInterface block×*4○*1○*5*6○*1*2*3○*1: FX3U, FX3UC supported from version 2.21 or later.*2: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*3: FX3UC-32MT-LT(-2) is not supported.*4: FX3G supported from version 1.00 or later.*5: When connecting to FX3GC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*6: FX3GC supported from version 1.40 or later.page topSensor SolutionModelApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX3U-128BTY-MAnyWire Bitty seriesmaster block×*1○Max.1 unit*3○Max.1 unit*2*4○Max.1 unit*3*4○Max.1 unit FX3U-128ASL-MAnyWireASLINK systemspecial adapter×*1○Max.1 unit*3○Max.1 unit*2*4○Max.1 unit*3*4○Max.1 unit*1: FX3G supported from version 1.00 or later.*2: FX3GC supported from version 1.40 or later.*3: FX3U, FX3UC supported from version 2.20 or later.*4: When connecting to FX3GC, FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.page topRS-232C communicationModelCommunication FunctionApplicable FX PLCN:N networkParallel LinkComputer LinkNon-Protocol CommunicationPeripheral device communicationFX3SFX3GFX3UFX3GCFX3UC FX3G-232-BDFunction expansionboard for RS-232Ccommunication××○○○*10○Max.1 unit*1○Max.2 units××× FX3U-232-BDFunction expansionboard for RS-232Ccommunication××○Max.1 unit×*2○Max.1 unit FX3U-232ADP-MBSpecific adapterfor RS-232Ccommunication××○○○*11○Max.1 unit*1*3*7○Max.2 units*4*8○Max.2 units*9○Max.2 units*4*8○Max.2 units FX2N-232IFSpecial blockfor RS-232Ccommunication×××○×××○Max.8 units×*5*6○Max.8 units*1: FX3G 14pt, 24pt models: 1 unit. 40pt, 60pt models: 2 units.*2: Can only be connected to FX3UC-32MT-LT(-2).*3: When connecting to FX3G, FX3G-CNV-ADP is required.*4: When connecting to FX3U,FX3UC-32MT-LT(-2), Function expansion board is required.*5: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*6: For FX3UC-32MT-LT(-2), 7 units. For FX3UC-**MT/D, FX3UC-**MT/DSS, and FX3UC-16MR/D(S)-T, 8 units.*7: FX3GC supported from version 1.30 or later.*8: FX3U, FX3UC supported from version 2.40 or later.*9: FX3GC supported from version 1.40 or later.*10: Function expansion board and FX3S-CNV-ADP cannot be used together.*11: When connecting to FX3S, FX3S-CNV-ADP is required.page topRS-485 communicationModelCommunication FunctionApplicable FX PLCN:N networkParallel LinkComputer LinkNon-Protocol CommunicationPeripheral device communicationFX3SFX3GFX3UFX3GCFX3UC FX3G-485-BDFunction expansionboard for RS-485communication○○○○×*8○Max.1 unit*1○Max.2 units××× FX3G-485-BD-RJFunction expansion boardfor RS-485 communication(RJ-45 connector type)*8○Max.1 unit*1○Max.2 unit××× FX3U-485-BDFunction expansionboard for RS-485communication××○Max.1 unit×*2○Max.1 unit FX3U-485ADP-MBSpecific adapterfor RS-485communication○○○○×*9○Max.1 unit*1*3*5○Max.2 units*4*6○Max.2 units*7○Max.2 units*4*6○Max.2 units FX-485PC-IF-SET RS-232C/RS-485converter interface××○××○○○○○*1: FX3G 14pt, 24pt models: 1 unit. 40pt, 60pt models: 2 units.*2: Can only be connected to FX3UC-32MT-LT(-2).*3: When connecting to FX3G, FX3G-CNV-ADP is required.*4: When connecting to FX3U,FX3UC-32MT-LT(-2), Function expansion board is required.*5: FX3G supported from version 1.30 or later.*6: FX3U, FX3UC supported from version 2.40 or later.*7: FX3GC supported from version 1.40 or later.*8: Function expansion board and FX3S-CNV-ADP cannot be used together.*9: When connecting to FX3S, FX3S-CNV-ADP is required.page topRS-422 communicationModelCommunication FunctionApplicable FX PLCN:N networkParallel LinkComputer LinkNon-Protocol CommunicationPeripheral device communicationFX3SFX3GFX3UFX3GCFX3UC FX3G-422-BDFunction expansionboard for RS-422communication××××○*3○Max.1 unit*1○Max.2 units××× FX3U-422-BDFunction expansionboard for RS-422communication××○Max.1 unit×*2○Max.1 unit*1: FX3G 14pt, 24pt models: 1 unit. 40pt, 60pt models: 2 units.*2: Can only be connected to FX3UC-32MT-LT(-2).*3: Function expansion board and FX3S-CNV-ADP cannot be used together.page topUSB communicationModelCommunication FunctionApplicable FX PLCN:N networkParallel LinkComputer LinkNon-Protocol CommunicationPeripheral device communicationFX3SFX3GFX3UFX3GCFX3UC FX3U-USB-BDFunction expansionboard for USBcommunication××××○××○Max.1 unit×*○Max.1 unit*: Can only be connected to FX3UC-32MT-LT(-2). 

Link supplier or manufacturer »

Electrical Control System: Delta Mitsubishi, Siemens, High-Speed Pulse Controller PLC Programmable Logic Controller Fx3u/Fx5u/Fx2n/Fx3g/Fx3ga S7-200/Dvp32es/Dvp-Eh/Ab
Kaiyuan Kyb Variable Frequency Adjustment Control Panel Frequency Conversion Control Cabinet3557byte
Double Pump Controller with RS485 Phase Loss Protection4775byte
Dp Bus Connector 6es7972-0ba12-0xa0 Programmable Logic Controller PLC Automation Industrial Controls PLC3186byte
Tu81 ATV610d45n4 ATV930u30n4z Bmep583040 Millenium 3 CD12 Analog Input PLC Controller2547byte
Mitsubishi Servo Drive MDS-DH-V2-4040 MDS-DH-V2-4020 MDS-DH-V2-80401425byte

Hollysys High Performance & Reliability Functional Safety Sil2 Programmable Logic Controller Lks PLC2733byte
Mochuan IP65 TFT LCD TFT Display Mini HMI Monitor Touchscreen Human Machine Interface5683byte
Plug-in Modbus Io Coupler Standard PLC Slave Device Expandable Digital Analog Input and Output Io Module China Manufacturer CE Certification5198byte
China 380V Online Type Soft Starter 3 Phase 5.5-800kw 55kw 75kw 220kw Soft Starter for AC Motor5197byte
48V 1000W 1500W Brushless DC Motor Speed Controller Can RS232 Control 80A Dual Driver2956byte

Integrated Soft Starter Builtin Bypass Contactor Motor Controller7923byte
Ifm Cr0032 Programmable Controller for Mobile Machines1373byte
B&R Servo Drive Acopos 8V1320.00-2 8bvi0014hwd0.000-1 Acopos Smicro6249byte
Electromagnetic Flowmeter Power Board E+H 71142657 Inverter Motherboard1634byte
6es7321-1bl00-0AA0 Siemens S7-300 Module Brand New Original 6es73211bl000AA0 PLC3055byte

Isolated Safety Barriers Sil3 Functional Safety Level Signal Converter1327byte
Allen Bradl-Ey PLC Controller Soft Starter CPU Intelligent Controller Gaming Computer908byte
Most Popular 3-Phase AC Thyristor SCR Power Controller Power Regulator for Temperature Control5596byte
Original 16 Point Programmable Controller PLC Delta Dvp-Ec Series Dvp16ec00r3 in Stock7866byte
CHINT RTD signal isolator and barrier 1 channel 1 in and 1 out3530byte

Brand New Original PLC Inverter Drive Soft Starter ATV930d37n4 ATV630d37n4 ATV320u75s6c ATV340d22n4 ATV71HD18n4 ATV71ld27n4z ATV212HD22n4 ATV340d30n4e3347byte
Original New Delta Dvp14ss2 PLC Dvp Module Controller Dvp14ss211t3216byte
Flexem PLC FC5-30MN-DC Controller, 18 Inputs, 12 Relay Outputs, IEC 61131-3 Programming2668byte
Portable Transformer Oil Chromatography Quick - Check Monitor System3838byte
Siemens CPU Central Processing Unit 6es7516-3ap03-0ab0 Brand New Original1054byte

Device 6AG1124-0gc01-4ax0 Industry Display Monitor Smart Control HMI Touch Screen4054byte
10kv 1500kw Motor Starter Usded in Water Pump5034byte
Golden Sourcing Season Split-Design Integrated Module for Modern Industry Supporting Multiple Signal Types4932byte
Gold Seller Interface Module PLC Controller Brand New Original Spot1586byte
Le Series Compact PLC Le5107L4692byte

Delta Mitsubishi, Siemens, High-Speed Pulse Controller PLC Programmable Logic Controller Fx3u/Fx5u/Fx2n/Fx3g/Fx3ga S7-200/Dvp32es/Dvp-Eh/Ab34755byte
Three Phase Motor Soft Starter SSD60 for Water Pumps5336byte
Ampstech Low Voltage DC Servo Driver 48VDC 1000W for Agv AMR Robot3121byte
Smart Electric Valve Controller Ball Valve Manipulator DN15 to DN32 Alexa1347byte
Original Simatic S7 300 Sm321 PLC Module 6es7321-1bl00-0AA0 for Siemens1590byte

12s 80A 48V 5HP Agricultural Uav Drone Brushless DC Motor Automatic Control Drive1549byte
High Performance 4.3inch 10inch Human Machine Interface LED HMI Display Screen 7inch Industrial Controls2003byte
Hot PLC 8lva23. B1030d000-0 8bvi0880hcs0.000-1 8bvi0880hwd0.000-1 8bvp0880hc00.008-1 8ei8X8hwt10.0500-1 8ei8X8hws10.0500-1 8ei8X8mwt30.01zz-1 8ei4X5hwt10.0100-15006byte
AV Over Fiber Kvm Host with Enhanced Signal Quality for Command Control Center2774byte
Electro-Pneumatic New Rotork Ytc Yt-3100lsz1101s Original Smart Positioner2416byte

Modbus to BACnet/IP Building Automation Protocol Converter with Ethernet Port and RS-232/485 Serial Port2875byte
Real Time Wireless Temperature Monitoring System for Switchgear Busbar and Cable2065byte
Safety Valve 8301-Af-00-DN200 8b0c0320hwoo. 002-1 X20bc0083 9A0100.11 X20at4222 8msa2X. R0-43 8bxf001.0000-00 8lva2s. B1030d100-0 X20PS2100 X20bm015006byte
26 Circuit Ship DC24V Navigation Light Control Panel2027byte
Control Frequency Converter Inverter Mdx61b0008-5A3-4-0t1441byte

Lighting Console with Stable Quality and Industrial Touch Screen7899byte
6AV6644-0ba01-2ax1 Simatic Touch Screen Panel HMI Human Machine 6AV66440ba012ax11502byte
Honeywell SPS5710-2-LF 51198685-100 ATDI Power Supply module Brand New In Stock3686byte
24/48V PWM Rt Series Four-Quadrant Reversible DC Brushed Speed Driver Controller for Brush Motor2216byte
New Products 0.4-15kw Maxsine Ep5 Multi-Network Slim and High-Performance Servo Drive2035byte

New Fanuc Servo Drive A06b-6290-H328 Via DHL or FedEx 12 Months Warranty4794byte
Innovative Power Supply Control System Room for Petroleum Drilling Rigs1965byte
Performance-Driven Three Wheel Vehicle DC48V 60V 72V 1800W Customizable Motor Controller1250byte
Original Omron-Corporation Cp1h-Xa40dt-D PLC Controller PLC Module Stock Programmable Logic Controller1366byte
Pluggable Relay Module for Control Cabinet with UL/CE/CQC2052byte

Reliable 1 in 2 out PT100 Temperature Signal Isolator for Resellers4372byte
HMI Human Machine Interface Touch Panel 7 Inch Touchscreen Dispay Unit5581byte
Smart Pump Management System for Enhanced Performance Optimization3604byte
60kw EV Charger Charging Station Europe Standard on Sale Now1856byte
Modicon Power Supply Ablpia24062/Servo Motor PLC Supplier CPU Module/1fk7101-3bf71-1rh1 Siemens Servo Motor/43368byte

6es7223-1bh32-0xb0 S7-1200 Series PLC Controller New Original Warehouse Stock8175byte
PLC Programmable LED Controller Xinje Xc2 Series Mini PLC Controller Xc2-16r-E3789byte
6SL3130-7te23-6AA3 Brand New Original Sinamics S120 Smart Line Module Input3137byte
Online Soft Starter Motor Drive Without AC Contactor 380V Low Voltage 15kw1888byte
Ci840A Communication Module for Dcs Solutions and Automation2063byte

New Original Siemens Simatic HMI 6AV6643-0ba01-1ax0 Operator Panel with 5.7" TFT Display4738byte
6ED1052-1fb08-0ba1 Programmable Logic Controller Module PLC Logo! Host Module1812byte
Golden Sourcing Season High-Performance Three-Part Io Module for Automation with Easy on-Site Maintenance4816byte
Mochuan Modbus RTU TCP RS485 Ethernet 10 Inch HMI Operation Panel5209byte
Ifm Cr0200 Programmable Controller for Mobile Machines3347byte

Temperature Thermal Resistance Input Explosion-Proof Isolated Safety Barrier Intrinsic Safe Barrier2060byte
Siemens PLC Breaker 6es7518-4fx00-1ab0 3rn1010-1cg00 3nh3430 3rh1140-2bb40 PT570024 3RV1011-1ka20 7pr4140-6pH00 3rt2018-1ap01 3RP2005-1bw304025byte
Original Simatic S7 300 Plcmodule 6es7321-1CH20-0AA0 for Siemens PLC10496byte
Customized Medium Voltage Soft Starter Cabinet 710-4500kw 2-11kv with Thyristor Control5034byte
Simatic S7 Series 1200 Step 7 PLC Fiyat Digital Input Output Sm1223 6es7223-1bh32-0xb0 Price1586byte

Zw32-36.2kv Outdoor Pole Mounted Vacuum Auto Recloser10031byte
Siemens 6es72385xa320xb0 Electricity Measurement Module Expansion Module4515byte
Bmxddo6402K Discrete X80 - 64 Outputs - 24 V PLC Controller Splitter Modicon M340 Industrial PLC2209byte
Pm5670-2eth 3abd00038896 AC500 S500 PLC 1sap151000r0378 Original Spot Industrial PLC Automation PLC1515byte
Gk-100-Pnrt 100mA@24VDC Profinet Adapter New Remote Control Solution for PLC System4204byte

Brushless motor controller 48V 800A 1000A motorcycle controller bicycle controller8270byte
4-20mA Signal Isolator to 0-10V 0-5V 1-5V Analog Signal Converter DC24V 1 in 3 out 1 in 4 out Galvanic Signal Transmitter4723byte
Intelligent Adjustable Pressure Pump Control Switch TUV Certificated2198byte
Original Brand New Industry Controls PLC Base Unit 6es7193-6bp00-0da01645byte
New Original Siemen S Simatic S7-1500 6es7532-5hf00-0ab0 PLC Controller in Stock PLC Programming Controller1512byte






Purchasing Agent


Note: Send your message to supplier or manufacturer.

Welcome to our Professional and comprehensive procurement services...

Message:


Post Sourcing Request Now »

  • Professiona Secured Trading Service
  • Verified Business Licenses to Supplier or Manufacturer
  • Welcome to our Global alliance Member