CIPDB › China Industry › Instruments & Meters › Electrical Control System
FL8-E8-D 8 Point Motion Control PLC. Ethercat Codesys, Digital1
Electrical Control SystemDigitalIndustrial PLCHigh-Speed Ethercat
Shanghai Flexem Technology Co., Ltd.
Preview:
Product Description Overview Range Of Product FL8Product Or Component Type Logic controllerRated Supply Voltage[Us] 24VDCDiscrete Input Number 8Discrete Output Type NPN TransistorDiscrete Output Number 8Discrete Output Voltage DC 5V~30V;Discrete Output Current/PointMax 2ADiscrete Output Current/GroupMax 4AProduct List Series FL8Reference FL8-E8-D FL8-E16-D FL8-E32-DCPU Quad-core 1GHz Memory 1GB 2GB 2GBHD 4GB 8GB 8GBMotion Axis8 Axis of EtherCAT+Pulse Axis16 Axis of EtherCAT+Pulse Axis32Axis of EtherCAT+Pulse AxisPulse Axis 6 axis 200KHzLeft ExpansionSupport left expansion (4G Cat1 or WiFi wireless, serial port)Ethernet 2 x 100MEthercatSupport (EtherCAT master station * 1, support up to 72 slave stations)Serial port 2 x RS485CAN communication1 x CANOPENProgram Storage32MUser Data Storage128MData Storage128KBytes in area I, 128KBytes in area Q, 512KBytes in area M, 800KBytes in retain area, other variables: unlimitedOther connectorsUSB flash disk (TYPE-C) program download, data storageMotion Function,CAM, Gear, linear interpolation, circle interpolationHSC 7 point 200KHzBuild in IO8-point input (source/sink), 8-point output (NPN)Right ExpansionMax 31 IOProgram languageCodesys 3.5.19.0(IL,LD,ST,SFC,CFC,FBD)Power DC24V±20%Bus ProtocolEtherCAT, Modbus-TCP, Canopen, Modbus-RTU, OPC UAReal-timeclockRTC integratedTransistor InputCharacteristics ParameterRated Voltage DC 24VInput Range DC 0V~28.8VRated Current 7mAPeak Voltage:30V Peak Current 9mAVoltage in state 1 >15VVoltage in state 0 <5VCurrent in state 1 >2.5mACurrent in state 0 <1.0mAIsolation -Optocoupler Input impedance 3.3kΩFilter timeDefault 1ms, 16 equally divided levels selectable from unfiltered to 100msCompatibilityCompatible with 2/3 wire sensorsInput type Source/SinkCable length and typeMax 100m shielded cable, 50m unshielded cableProtection (overvoltage) Maximum 30V, limited to 1 hour per day frequencyWiring terminalRemovable terminal blockTransistor OutputCharacteristic ParameterOutput type NPNRated voltage DC 24VVoltage range DC 19.2V~28.8VRated current 2ACurrent/goup4A* Output point of each groupVoltage drop Maximum 1V DCLeakage current when turned off <5μAMaximum power of incandescent lamp 2.4WDerating NoneStart time Maximum 34μsTurn-off time Maximum 250μsMaximum output frequency 1kHzShort circuit protection YesPeak short-circuit output current 1.3ASelf-recovery after short circuit or overloadPer 10msClamping voltage Maximum 39V±1V DCIsolation500V AC between output and internal logicType of Cable UnshieldedCable length 50m Unshielded 50mWiring terminal Removable terminal blockEnvironmental CharacteristicsCategory CharacteristicOperating ambient temperature-10oC~60oCStorage temperature -20oC~70oCRelative humidity 5%~95%, without condensationClass of pollution 2(IEC60664)Class of protection IP20CoatingCoated protection, dry film thickness ≥ 20μm; reinforced dry film thickness ≥ 40μmAltitudeOperation:0m~3,000m;Transportation:≤6,000mSeismic performance5~13.2Hz Amplitude 7mm, 13Hz~100Hz Acceleration 2G, 20 times each in X, Y and Z axesImpact performanceSemi-positive sine wave, acceleration 15G, duration 11ms, 6 times in each of the X, Y and Z directionsPowerSafety notes If the specified voltage range cannot be maintained, the output may not switch as expected. Please use a proper safety interlock and voltage monitoring circuit.Required for the PLCs and associated I/O extension modules. According to IEC 61140, the 24 V DC power supply must be rated for Safety Extra Low Voltage (SELV) or Protected Extra Low Voltage (PELV). These power supplies are isolated between the electrical input and output circuits of the power supply.The PLCs must be supplied by a 24 V external power supply device. During a power failure, the PLC associated with a suitable power supply can continue to operate normally for at least 10 ms according to the IEC standard.Make sure the external DC power supply meets the following characteristic requirement.Characteristic ValueRated voltage 24V DCSupply voltage range 19.2V~28.8V DCPower interruption time 10 ms at 24V DCMaximum peak current 3AMaximum power consumption6.5W
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...