China, Chinese Xtkb-700 Low Voltage Switchboard/Switchgear/ Power Control Center Distribution Cabinet Control Panel1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Products Details Supplier Manufacturer price list catalog
Electrical Control SystemSwitchgear ControlCabinet Indicator
Welcome (Wenzhou) Electric Co., Ltd
Preview:
Product Description 1. Analog Indication InstructionsCircuit Breaker Status Indication (Passive Contact Input): When the circuit breaker is closed, the closing contact closes, and the red vertical analog bar lights up; when the circuit breaker is open, the opening contact closes, and the green horizontal analog bar lights up.Handcart Position Indication (Passive Contact Input): When the working - position contact closes, the red vertical analog bar lights up; when the experimental - position contact closes, the green horizontal analog bar lights up.Spring Energy Storage Indication (Passive Contact Input): When the contact closes, the red LED lights up, indicating that energy has been stored; when the contact opens, the LED does not light up, indicating that energy has not been stored.Grounding Switch Position Indication (Passive Contact Input): When the contact closes, the red vertical analog bar lights up, indicating that the grounding switch is closed; when the contact opens, the green vertical analog bar lights up, indicating that the grounding switch is open. Note: All lighting indications do not light up in the power - off state. The above contact signals are all from the auxiliary contacts of the circuit breaker.2. High - Voltage Live Indication PartLED Starting Voltage (KV): Bus voltage × 0.15 - 0.65Lock - out Starting Voltage (KV): Bus voltage × 0.65When the three phases are all de - energized, the lock - out is released, and the electromagnetic lock is activated.3. Temperature and Humidity Control PartSensor Channels: Two channels for condensation and two channels for temperature.Logical Relationship: When the ambient humidity is higher than 85%RH and the conditions for condensation are met, heating is started; when the ambient humidity no longer meets the condensation conditions, the device automatically stops heating. The humidity control accuracy is ±2%RH. When the ambient temperature is lower than 5°C, the system starts heating; when the ambient temperature is higher than 15°C, the system automatically stops heating. The temperature control accuracy is ±2°C.Open - circuit Alarm: When the heater has an open - circuit, the corresponding alarm indicator light lights up, and the alarm output contact closes.Forced Heating: When the forced heating switch is in the manual position, the heating output is executed unconditionally. When it is in the automatic position, the device automatically operates according to the above - mentioned control logic.4. Voice Error - prevention FunctionWhen the circuit breaker is in the closed state and the handcart is mistakenly pushed from the test position to the working position, a voice prompt "Please open the circuit breaker" will be given.When the grounding switch is in the closed state and the handcart is mistakenly pushed from the test position to the working position, a voice prompt "Please open the grounding switch" will be given.When both the circuit breaker and the grounding switch are in the closed state and the handcart is mistakenly pushed from the test position to the working position, voice prompts "Please open the circuit breaker" and "Please open the grounding switch" will be given.5. Operation FunctionsOpening operation, energy - storage operation, remote/local operation, and cabinet interior lighting operation.6. Optional FunctionRS485 communication function.External DimensionsConnection DiagramHot products
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...