CIPDB › China Industry › Instruments & Meters › Electrical Control System
China, Chinese Ard3m Low Voltage Motor Protection and Control Relay Max 800A1 Industrial Products Supplier Manufacturer Details, price list catalog:
Electrical Control SystemMotor Protection RelayProtection Relay
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Preview:
Product Description Acrel Three Phase ARD3M Smart Motor Protection RelayIn the field of industrial control, electric motors are the core power of production lines, but frequent failures often lead to equipment damage, production stoppages and even safety accidents.Traditional motor protection methods:The circuit breaker provides short-circuit protection for the main circuit;Overload protection is provided by thermal relays;Disadvantages: simple functions, faults are difficult to troubleshoot and cannot be located.ARD3M intelligent motor protection controller is suitable for AC motors below 660V. It integrates protection, measurement, control and communication, provides fault records, assists in rapid fault location, extends motor life and improves production efficiency.Core functions: complete protection functions, support for multiple starting modes, integrated MCC function;Advantage functions: insulation monitoring, waveform recording, anti-electrical shaking, PROFINET communicationInstallation: It adopts split structure design, the main body and display unit are connected by network cable, easy to install, suitable for harsh industrial scenes such as high temperature and high humidity. Type: Smart Motor Protector Function:Phase loss,overload,locked rotor,blockage,three phase unbalance protection,etc. Measurement:Active kWh (positive and negative),quadrant reactive power energy. Electrical measurement: U,I, P,Q,S,PF,F,THDv,Harmonic on 2nd-31st,etc Communication:RS485, WIFI Protocol:Modbus-Rtu,MQTT Installation:Separated type or integrated How we can help you? The power module supports the power range of AC/DC100-415V. Support fundamental wave and full wave power parameter measurement (U, I, P, Q, S, PF, F, EP, EQ), voltage and current unevenness Balance, voltage, current positive sequence, negative sequence, zero sequence components, three-phase voltage phase angle, residual current, voltage, current 2-63 times Sub-harmonic measurement, sub-harmonic content rate and total harmonic distortion rate. Protection functions include overload inverse time limit, overload definite time limit, grounding, starting overtime, leakage, underload, phase failure, blockage Turn, block, short circuit, overflow, unbalance (current, voltage), over power, under power, over voltage, under voltage, phase sequence, temperature degree, tE time, external fault, limit of starting times, running time alarm, fault times alarm.10 programmable DI inputs, the default is built-in DC24V power supply, and external active wet contacts can also be selected 6-channel programmable DO output, which can meet the requirements of direct starting, star-delta starting, autotransformer starting, etc.The remote control "start/stop" of the motor from the master station can be realized through the communication bus. Optional anti-shock function: support immediate restart after shock and restart after loss of pressure. Standard 2-way MODBUS_RTU communication, there are PROFIBUS DPV1, Ethernet, PROFINET communication modules for Optional. Optional 2-way DC4-20mA analog output interface, connected with the DCS system, can monitor the field equipment. It has various event records such as fault record, start record, stop record, DI displacement record and restart record, which can be checked View a number of motor operation and maintenance information, and at the same time record the motor running record for 1-5 hours. The display interface supports Chinese/English display. Support U disk to export waveform record and event record data, you can use EXCEL to open and export event record file. WIFI function can be added when the color LCD display is selected, and the WIFI can be connected to the mobile phone or computer to view and set the motor protection.Its perfect protection function ensures the safe operation of the motor, with logic programmable function, can meet a variety of control methods.Different communication modules can be selected to meet the needs of field communication. Dimension WiringNetworkingjust feel free to contact me to create a cloud platform experienced accountSpecificationThe standard switch quantity of ARD3M is 10DI and 6DO, and the switch quantity typeMain switch classification Code DI is the dry contact and the external power supply of DO is AC220V K1 DI is the wet contact, the input is DC110V, and the the external power supply of DO is AC220V K2DI is the wet contact, the input is DC220V, and the the external power supply of DO is AC220V K3DI is the wet contact, AC220V input, and DO external the power supply is AC220V K4This corresponds to the relation between ARD3M current specification and the rated current and power of the applicable motor Protector current specification (A) Ratio setting Primary side coil number of transformerApplicable scope of motor (kW) Suitable for motor Rated current range (A) 1Support5 circle 0.12-999 0.1-5000 51 circle 25not Support3-11 6.3-25 10015-4525-10025055-13263-250800160-250250-800Additional features of ARD3M Code Additional function H2-63 harmonic voltages and currents WRWaveform recording SUAnti-electric shock functionRiAnti-electric shock functionLElectric leakage protection SRFault record WIFIWireless function (optional with color dot matrix LIQUID crystal) CP1channel PROFIBUS DPV1communication 2CP2 channel PROFIBUS DPV1communication MCEEthernet communication (MODBUS TCP protocol) PNET1channel Profinet communicationM11channel 4-20mA output M22 channel 4-20mA output FunctionItemARD3MApplication occasionsLow Voltage 0.4KV~1.14KV Motor ProtectionRated Current1(ratio)(0.1-5000A)5(ratio)(0.1-5000A)25(6.3-25A)100(25-100A)250(63-250A)800(250-800A)DimensionPanel mm98*60Cut-out mm92*55ProtectionStartup timeoutYesOver-loadYesUnder-loadYesShort CircuitYesStallYesBlockYesCurrent UnbalanceYesVoltage UnbalanceYesExternal FaultYesStructural FailureNoInternal FaultNoOver-voltageYesUnder-voltageYesOver-powerYesUnder-powerYesLack of phaseYesPhase SequenceYesTEYesTemperatureYesMulti-channel temperature protection Overflow protectionYesInsulation monitoringYesNumber of starts alarmYesRunning time alarmYesNumber of fault alarmYesAnti-shakeOptionalAnalog input protectionNoGroundedYesLeakage CurrentOptionalCommunicationModbus-RTUNo2 Channels of Modbus-RTUYesProfibus-DPOptional2 Channels of Profibus-DPOptionalProfinetOptionalModbus-TCPOptionalWIFIOptionalSignalDI10+DO6+Start controlYes4-20mA OutputOptional2 channels of 4-20mA OutputOptionalFault Record8OptionalRunning Record5hOptionalWaveform Record40OptionalDI Displacement Record8YesStart and stop Records8YesRestart Record8YesLogic functionTimerNoCounterNoTruth tableNoLogic diagramNoMeasureThree-phase currentYesLeakage currentOptionalThree-phase voltageYesPositive sequence negative sequence zero-sequence currentYesPositive sequence negative sequence zero-sequence voltageYesActive power, Apparent powerYesReactive powerYesFrequencyYesActive energyYesReactive energyYes2-63st HarmonicOptionalPTC/NTCYes4-20mA InputNoTemperatureNoDisplayLEDNoMonochrome LCDOptionalColor LCDOptionalProduct ParametersTechnical parametersTechnical indicatorsProtector auxiliary power supplySupport two power modules, AC 220V power module (AC85-265V/DC100-300V) default, AC 380V power module (AC/DC100-415V) optionalRated working voltage of the motorAC220V / 380V / 660V,50Hz / 60HzRated operating current of the motor1 (0.1A-5000A)External current transformer5 (0.1A-5000A)25(6.3A-25A)100(25A-100A)250(63A-250A)800(250A-800A)Relay output contact capacityImpedance loadAC250V,10ASwitching input10 channels of passive dry contact (active DC110V, DC220V, and AC220V input can be optional)CommunicationStandard supplied2channel MODBUS RTU communicationOptional(only one can be selected)1-2 channel PROFIBUS DPV1communication,1channel PROFINET communication, Ethernet communication(MODBUS TCP protocol)EnvironmentWorking temperature-10oC~55oCStorage temperature-25oC~70oCRelative humidity≤95%No condensation, no corrosive gasAltitude≤2000mPollution levelsClass 3Protection gradeMain body IP20, split display module IP54 (installed on the cabinet panel)Installation categoryLevel IIIComposition Application Company ProfileAcrel Co., Ltd.[stock code: 300286.SZ] is a high-tech enterprise that integrates R&D, production, sales, and service, since its establishment, is committed to providing users with energy efficiency management and powerful security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors. Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.The company attaches great importance to product quality and innovation. By the end of 2018, the company has 5 trademarks, 18 invention patents, 72 utility model patents, 94 appearance patents, and 147 computer software Copyrights, and has participated in the formulation of national or industrial standards.
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...