CIPDB › China Industry › Instruments & Meters › Demonstrational & Teaching Utensil
Medical Full Body Child Baby CPR Manikin Training Mannequins1
Demonstrational Teaching UtensilCPR ManikinCPR Manikin Training
Guangzhou MeCan Medical Limited
Preview:
Product Description Medical Full Body Child Baby CPR Manikin Training MannequinsModel:MCE0048Features:1.Simulate standard open airway2. External breast compression: display device and alarm devicea. indicator light display of correct and wrong compression ; alarm of wrong compressionb. intensity display of correct (2--3 cm) and wrong (<2cm or >3cm) compression; alarm of wrong compression3.Artificial respiration (inhalation): display device and alarm devicea.Inhalation <150-200ml or >200ml, wrong indicator light display and alarm prompting; Inhalation between 150- 200ml right indicator light displayb.Inhalation too quickly or too much result in air entering into stomach; indicator light display and alarm prompting4.Ratio of compression and artificial respiratory: 30:2 (one person) or 15:2 (two persons)5.Operating cycle: one cycle includes five times of 30:2 or 15:2 ratio of compression and artificial respiration6.Operation frequency: at least 100 times per minute7.Operation methods: exercise operation8.Examination of carotid response: pinch the pressure ball by hand and simulate carotid pulse9.Working conditions: Input power is 110-240VPACKAGE SIZE80*30*40cmG.W.11.2KGSModel:MCE0049Features:1.Simulating standard open airway2. External breast compression: display device and alarm devicea.Indicator light display of correct and wrong compression ; alarm of wrong compression;b.Intensity display of correct (1-2 cm) and wrong (<1cm or >2cm) compression; alarm of wrong compression3.Artificial respiration (inhalation): display device and alarm devicea.nhalation <30ml or > 50ml, wrong indicator light display and alarm prompting; Inhalation between 30- 50ml right indicator light display;b.Inhalation too quickly or too much result in air entering into stomach; NEW indicator light display and alarm prompting4.Ratio of compression and artificial respiratory: 30:2 (one person) or 15:2 (two persons)5.Operating cycle: one cycle includes five times of 30:2 or 15:2 ratio of compression and artificial respiration.6.Operation frequency: at least 100 times per minute7.Operation methods: exercise operation8. Examination of brachial artery response: pinch the pressure ball byhand and simulate brachial artery pulse9.Working conditions: Input power is 110- -240VPACKAGE SIZE: 62*22*37cmG.W.10KGS
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...