Send

Food Packaging Bag

Gift Box & Bag

Industrial Packaging Bag

Logistics Packaging

Machinery for Packaging Supplies

Non Woven Bag

Other Bags & Cases

Package & Conveyance

Package & Printing Service

Packaging Bags

Packaging Materials

Packing Bottle

Packing Machinery

Post-Press Equipment

Pre-Press Equipment

Printing Machinery

Printing Materials

Shopping Bags

Specialized Case & Box

Stencil

Tag & Sign

Tag Gun

Tool Packaging

Watch Box

CIPDBChina IndustryInstruments & MetersElectronic Instrument



Lh1500 Online Gas Leakage Analyzer1

« Previous Next »

Electronic InstrumentGas Leakage AnalyzerHydrogen Leakage Detection

Haiyan Jinhan Import-Export Co., Ltd.

Preview:

Product Description LH1500 Online Gas Leakage Analyzer (hereinafter LH1500) is specially designed instrument to precisely detect the gas leakage. It is widely used in such areas as electric power, steel, petroleum, chemical, shipping, tunnel, etc. to perform online leakage detection of gases( for example, flammable gases like hydrogen, methane). The instrument takes advantage of world leading sensing technology, which can monitor the area simultaneously with multi points in real time. The system consists of one host machine and 8 gas sensitive transmitters, and is flexible control. Structure featuresLH1500 use the split-type design which separates the host machine and the transmitters. The host is placed in the safety zone and the transmitters are placed in dangerous zone where may accrue gas leakage. The protection class reaches IP54. The 8-18 transmitter channel can be arbitrary choice. The host machine consists of signal acquisition, signal conversion, display unit and cabinet, which are easy to install. Working principle  The signal from the gas sensitive transmitters is converted into digital signal by the high precision A/D converter and displayed on the industrial true color LCD after processed by the embedded CPU. Through the converter and the corresponding circuit, it can realize output of (4~20) mA analog signal, also output of RS485 digital signal . The user can use the panel buttons to operate the instrument. Technical featuresPerformanceIndustrial true color LCD, high definition display, human-machine interface windows, the drop-down menu.8 lines of (4~20) mA analog transmitter input interface which has the most analog channels inthe same kind product, compatible with 3-wires transmitter and 2-wires transmitter.On the same host machine, every transmitter can be configured individually, monitoring different gas types, ranges and data units.Reserved digital transmitter input interface: 1 line RS485 connecting intelligent device, such as GD6102 gas flow purity analyzer and so on.Output interface: 8 lines (4~20) mA, 8 lines H alarm, 1 line total alarm. Use large capacity flash memory chip to save the historical data, no data losing when power-off, every minute store a set of data which can be stored for 100 days, user can query data by date. The platform circuit design, use advanced ARM digital processing technique, high reliability and great anti-interference performance. ParametersWorking conditions Working temperature:(0~50) oC.Relative Humidity:<90%(25 oC) .Environment pressure:(86~110) kPa.Non corrosive gas or vapor environment.In no significant shake and shock place. Technical parameterTechnical parameter of LH1500 online gas leakage analyzera) Power Supply:(110~240) V AC;(50±2) Hz;≤0.25 A. Measurement range and Accuracy: Gas typeMeasurement rangeAccuracyHydrogen(0.0~4.0)%H2(0.0~2.0)%H2, ±0.2%H2(>2.0~4.0)%H2,±0.3%H2Response time: <30 s.Display mode: industrial grade high-definition LCD screen.Analog input: (4~20) mA.Digital input: RS485.Analog output:(4~20) mA, 500Ω of maximum load resistance.Alarm output: H alarm which can be set SPST.Alarm output contact capacity: 250 V AC/5 A; 30 V DC/5 A.Measurement channels: ≤8 lines. Explosion grade:Host machine:[Ex ia Ga]C. Transmitter:ExiaC T3 Ga.Outline dimension of host machine:(460×350×130) mm.Weight: Host machine ≤10 kg; Transmitter ≤0.9 kg. Technical parameter of GD6102 gas flow purity analyzer transmitter Measurement range: ItemModelNameRange1GD6102-PGas purity analyzertransmitterPurity:(0.0~20.0)%2GD6102-HGas flow purity analyzertransmitterPurity:(0.0~20.0)%Flow:(60~1000) L/hPurity measurement precision:±2.0%FS(Standard status)Flow measurement precision:±2.0%FS(Standard status) .Power supply:12 V DC.Ex Type:Exd ia C T4 Ga.Pipe size:DN15,(22×3).Sampling pipe material: stainless steel.Cable interface size: (6~10) mm.Outline dimension:(280×150) mm.Weight: about 2 kg per transmitter. InstallationThe connection diagram of LH1500 and the Generator as shown below: Figure 5.1 the connection diagram of LH1500 and the Generator Mounting the host machineMounting the host machineRefer to the host bracket dimension in Figure 5.2, fix four M8 expansion screws on the wall next to the generator bus bar, and install the host on the expansion screws, insert Φ8 plain washer and spring washer, and then tighten the M8 nuts to complete the host installation.Figure 5.2 Host bracket Note: The installation location need good ventilation and should leave more than 1m space around for operation and maintenance.Wiring the host machineOpen the front cover of LH1500 host to operate the wiring terminals. The following will introduce the function of every terminal.The host terminals of 8 channels distribute in three fixed plates which includes left board, middle board, right board as shown in Figure 5.3.Figure 5.3 wiring terminal block plate diagramTerminal block definition Terminal fixing plate nameTerminal definitionLeft boardRS485 signal1~8 line transmitter inputMiddle board1~8 line current signal outputRight board1~8 line H alarm and total H alarm signal outputThe terminal definition of left board:The left board is RS485 signal and 1 ~ 8 line transmitter input to connect the transmitter, the labeled "V" indicates the positive power of the transmitter ( 12 V, 300 mA maximum current output), "G" is the negative power of the transmitter, Mark of "S" is for (4~20) mA signal of the transmitter, the labeled "1#" is the first line of the transmitter input interface, "8#" is the eighth line of the transmitter interface, the labeled "RS485" is the transmitter input interface of the Gas purity analyzer.Figure 5.4 Left board wiring definition The terminal definition of middle board:The middle board is (1~8) line current output signal to upload to the DCS. The labeled "IOUT1+" is the first line of positive current output; "GND" is for the negative power output; Mark of "1#" is the first line of current output interface, Mark of "8#" is the eighth line of current output interface.Figure 5.5 Middle board wiring definition The terminal definition of right board:The right board is (1~8) line H alarm and total H alarm signal output to upload to the DCS. Thelabeled "1C" is the common terminal of the first line alarm signal; labeled "1NO" is the first line of alarm signal normally open; Mark of "1#" is the first line of H alarm interface of the transmitter, mark of "8#" is the eighth line of H alarm interface of the transmitter, the alarm mode is SPST normally open type, the relay is closed if alarm occurs. Mark of "ALA1" is the total alarm interface; the alarm mode is SPST normally open type, the relay is closed if any route/line of alarm is triggered.Figure 5.6 Right board wiring definition Mounting LH1500 transmitterThe transmitter typeAccording to the performance characteristic and installation location, the transmitter has the following types.ItemSpecificationPerformance characteristicLocation1LH1500-AThe ventilation diffusion window is larger which suitable for hydrogen leakage detection inspace environmentEnvironmental space2LH1500-BWith filter tube bundleSteam side and excitationside, main oil tank3LH1500-CWithout filter tube bundle or hydrogensensitive membraneABC enclosed bus bar,neutral point4LH1500-EWith filter tube bundleWater return pipe Wiring the transmitterThe output voltage of the host machine is 12 V DC, the host and the transmitter use 3-wire connection, Mark of "V+" is for the positive power of the transmitter, Mark of "V-" is for the negative power of the transmitter,Mark of "S" is for (4~20) mA of the transmitter.The 3-wire transmitter definition: SIG connects the yellow wire of the transmitter output, GNDconnects the green wire of the transmitter output, +12 V connects the red wire of the transmitter output (the transmitter output uses three-core and three colors cable, see the diagram below. The color of the cable refer to the real object.)Figure 5.8 Wiring connections for 3-wire transmitter and host machine Mounting transmitterThe installation of Type A transmitter Figure 5.9 Type A transmitterType A transmitter mainly monitor the leakage of gas in Air. Use the M8×80 expansion bolt to install the fixed plate in the position of leakage detecting, and use the M8×20 hexagon socket cap head screws to fix the transmitter on the plate via four fixing holes.The scope of supply for the A Type transmitter (a single set): one Type A transmitter, one set of fixed plate. The installation of Type B transmitter    Figure 5.10 Installation diagram for Type B transmitter    Figure 5.11 Dimension diagram of Type B transmitter Note: Mount the B Type transmitter on the oil return pipe, weld it vertically, the opening size isΦ14. It should leave more than 0.5m space around the transmitter for easy operation and maintenance. Remove the vent screw from the probe if the pressure in the internal cooling tank or the oil return pipe is always positive.The scope of supply for the B Type transmitter (a single set): one LH1500-B transmitter, one stop valve DN10.The installation of Type C transmitter    Figure 5.12 Installation instructions for Type C transmitter in the Generator Bus bar    Figure 5.13 Type C transmitter fixing board Note: Mount the C Type transmitter vertically with the fixed plate on the upper outlet cavity of the bus bar and the neutral point. First, install the fixed plate of the transmitter on the bus, the installation hole opening size is 4×Φ8.5, and then weld the stainless steel gas tube in the middle fixed hole, the middle fixed hole isΦ14. It should leave more than 0.5m space around the transmitter for easy operation and maintenance.The scope of supply for C Type transmitter (a single set): one LH1500-C transmitter, one fixed plate for transmitter C.The installation of Type E transmitter    Figure 5.14 Installation diagram of Type E transmitter Open a hole on the water return pipe in the field which is not less than Φ20,and weld the pipe to the hole. The depth of the welding pipe inserted into the water return pipe is as short as possible.Connect the material showed in the figure 5.14 and turn off the needle valve before operating; Open the needle valve slowly and observe the flow rate of the outlet, adjust the flow rate to 30 mL/min; Use the G1/4 screw thread on the mounting seat joint of the transmitter to connect the the drainage pipe to the drain tank in the field.  Mounting GD6102 gas flow purity analyzer transmitterMode of connectionLH1500 online gas leakage analyzer is connected to GD6102 gas flow purity analyzer transmitter via RS485 digital signal. Internal connection between LH1500 and GD6102 terminal block is as follow:Figure 5.15 Connection diagrams of LH1500 online gas leakage analyzer and GD6102 gas flow purity analyzer transmitterMode of mountingOpen a hole ofΦ22 on the water tank. Select the appropriate height position to mount the transmitter. It must ensure that the water in the cooler does not enter the transmitter. It is recommended to weld approximately 2 m long pipe (DN15) vertically, weld the movable joint on the pipe and install the valve, connect another end of the movable joint to the transmitter by the screw thread. The outlet of the transmitter is connected to the manual stop valve which is normally closed. The specific installation dimension is shown below. Figure 5.16 Transmitter dimension diagram    Figure 5.17 Movable joint dimension diagrams Figure 5.18 Transmitter mounting diagram    Figure 5.19 Welding diagram Attention of Installation: Mount the transmitter vertically (The direction of air intake is perpendicular to the horizontal plane);The vertical distance between the transmitter installation location and the top of the stator cool water tank is not less than 2m;Reserve 0.5m space around the transmitter for maintenance.The scope of supply for GD6102 transmitter (a single set): one GD6102 transmitter, one stop valve DN15.Use and operation methodBoot interfaceTurn on the power switch and enter into the boot interface, software version info section, and system initializing, the instrument will enter into the measurement menu automatically after 5 seconds.Figure 6.1 Boot interfaceHere Vx.xx indicates the software version and yyyy-mm-dd is the date of the software version. MeasurementSelect "Measurement " in the main menu to enter the measurement display" interface, which displays as figure 6.2. Figure 6.2 Measurement display interfaceWith this measuring interface, 8 gas detection transmitter input channels of the instrument can be measured in real time, including gas, measured value, alarm status, daily maximum concentration value and maximum time.1) Interface instructionThe measurement interface consists of two parts: title display, channel display.Title Display: It can display the real-time measured data, gas type and the maximum value of the day from a particular channel in a larger font. Each channel is rotated every 5 seconds. Convenient for users to observe from a distanceChannel Display: it can display simultaneously the real-time measurement and status information of the 8 channels.Among them: the channel number, gas type and concentration value of the measurement channel are displayed as "--", indicating that the channel is not enabling state. Channels 4, 6, 7 and 8 are shown in the Figure 6.2.The Concentration displays "----" which shows the channel is disconnection, see Channel 1,5 in Figure 6.2The Concentration displays in red which shows that the channel is in H alarm condition. See Channel 3 in Figure 6.2  Main menu    Press  in measurement menu to enter the main menu. The user can select the function options .The main menu shows as Figure 6.3.Figure 6.3 Main menu1) Keys instruction:Press     to switch the main function menu;Press     to select the submenu under the main function menu.Press  to enter the selected interface when the selected option is green.Data queryUnder the main menu, select the data query menu, you can enter the data query interface. The historical alarm time and peak measurement data of each gas measurement channel are counted in hours.    SettingFigure 6.4 data query Setting includes the "Channel setting" and "System setting" sub-menu. Channel SettingSelect "Channel Setting" in setting menu to enter the interface.    Figure 6.5 channel settingIn channel setting, the user can select the channel and set the gas type which includes three modes: 1: none, 2: (4~20) mA, 3: RS485.Select (4~20) mA to display as below. Figure 6.6 channel settingIn this interface, the user can configure the upper and lower limit of the range which response to output (4~20) mA analogue signal. The upper alarm limit is set to the high alarm of the channel. After setting, select "Save" to save Settings.RS485 is connected to the transmitter of GD6102 gas flow analyzer, which is shown as follows.    Figure 6.7 Channel settingIn this interface, the user can configure the upper and lower limit of the range which response to output (4~20) mA analogue signal. The upper alarm limit is set to the high alarm of the channel, the H alarm value should be set within measurement range. Input the number of gas flow analyzer transmitter. After setting, select "Save" to save the configuration.If selected the GD6102 gas flow purity analyzer transmitter can measure the flow, it will display as below. Figure 6.8 Channel settingIn this interface, the user can configure the upper and lower limit of the range which response to output (4~20) mA analogue signal. The upper alarm limit is set to the high alarm of the channel, the H alarm value should be set within measurement range, and the equipment number is the number of gas flow analyzer transmitter, Reset interval is the time interval for cleaning up the accumulated gas volume. After the setting, select "Save" to save the configuration.System SettingIn System menu, the user can setup the time which show as below.      Advanced menuFigure 6.9 System Setting Select advanced menu in main menu to enter the advanced display interface. The advanced menu function is to test whether the current output and alarm output of the instrument are normal.      Current output testFigure 6.10 Advanced menu In this menu, the user can test the current output:First select the channel, you can choose a single channel or all channels Setup the current value within the range of (4~16) mA;Use ammeter to test the current output value. If there is no current output, need maintenance. Relay output testIn this menu, the user can test the relay output:First select the channel, you can choose a single channel or all channels Setup the relay status, off or closed;Use the multimeter to test whether the relay output is off or closed. If the status is incorrect, need maintenance.About menuIn main menu, the user select About menu to enter the About display interface. It Displays the product name, factory serial number, software version and hardware version and so on. Figure 6.11    About interfaceNotes:Factory serial number: xxxxxx indicates the serial number of the instrument. Software version: Vx.xx xxxxxxxx is for the software version of the instrument. Hardware version:xxxx xxxxxxxx is for the hardware version of the instrument.Key operation instructions:Press     to page turning ;Press    to switch the About interface and the main menu. CalibrationSummary:The calibration of LH1500 Online Gas Leakage Analyzer is mainly refers to the transmitters. It has been calibrated at the factory according to standard application conditions. Required Equipments and MaterialsZero Point Gas:Clean air Linear Gas:(1.50~2.50)% Hydrogen of standard gas(the background gas is air)Note: The calibration accuracy depends on the quality of zero point gas and standard gas as well as the accuracy of output current by the standard power supply. Calibration methods    Calibration methods are the same for each transmitter. See Figure 6.12 for the appearance dimension of the transmitter.Figure 6.12 Transmitter appearance dimensionBefore the transmitter calibration,the front cover of the transmitter should be taken off first, please turn it in anti-clockwise rotation, a circuit board will be found inside after screwing the cover slowly. The adjustable potentiometer is on the circuit board, the potentiometer zero mark as ZERO, and the potentiometer span mark as SPAN. The calibration method is as follows.Zero point calibration:Put the sensor side of the transmitter into the zero point gas (usually clean air). After the indication of the host machine gets stable, adjust the current to 0% with potentiometer ZERO (low in clockwise and high in anti-clockwise) if the reading is not 0%.Linear calibration : Input the linear standard gas to the inlet of the transmitter (recommendedstandard gas is (1.50~2.50)% Hydrogen and the background gas is air) and adjust the flow rate to (200~300) mL/min. After the host machine gets stable, if the display value does not accord with the standard gas, adjust the potentiometer SPAN (turn clockwise and counterclockwise) until the display value is consistent with the standard gas value. Follow the same operation to calibrate the other transmitters.When calibration completed, properly install the cover with the transmitter.Note:Make sure the correct wire connection otherwise the transmitter might be damaged. When calibration is performed in the field, do avoid of generating explosive gas mixture.Notes: Please contact the manufacturer or supplier for calibrating GD6102 gas flow purity analyzer transmitter.Calibration CycleUser calibration cycle: In the field, user can check the measurement accuracy with reference standards when the instrument is running. The calibration cycle of LH1500 online Gas leakage analyzer is 12 months. When the measured gas humidity is higher or the concentration of Hydrogen is higher, shorten the calibration cycle accordingly. The analyzer should be calibrated in time after replacing the main components or repairing.FAQ and Solutions Failure introductionReasonsolutionRemarksNo display on LCD whenpowering onNo power conductionCheck the powerAny unsolved problems occur, Please contact the factory ASAP.The transmitter display larger errorThe calibration data loses or changesRecalibrate or return to the factory ,or replace thesensor probeThe transmitter displaysdisconnectingThe transmitter is not wellconnected.Check the wiringClock has no changeThe button battery withoutelectricityReplace the batteryStorage and shippingThe packed host machine is suitable for any mode of transportation, but should be handled with care and keep away from inversion, sun, rain and strong vibration. The host machine should be stored in the warehouse where there is no corrosive gas and ventilate well. Open-package inspectionPlease check the instrument and its accessories are available against the packing list after unpacking, whether there is any damage during transportation, whether the documents and accessories are complete.OthersSpare partsPacking list Certificate Instruction manualRecycling and environment informationWhen the product life cycle ends or is scrapped, it should be handed over to the local state permitted units for recycling.After-sales servicesWe supervise on-site installation, guide commissioning, and give training to the operators. Warranty period is 12 months. Life-long maintenance of products is available with certain maintenance fee.During using the instrument, the damage caused by non-normal failure use (such as Lightning, voltage instability, damp or artificial factors, etc.) is not covered by the warranty. 

Link supplier or manufacturer »

Electronic Instrument: Lh1500 Online Gas Leakage Analyzer
Aileike104sg Manual Air Pressure Pump Ship Use Digital Pressure Gaugealkc400ha1pressure Conversion Joint Alkj01 0~580psi2601byte
High Accuracy Tzone Tempu 03 LCD USB Display Temperature Data Logger Recorder1325byte
High Quality Vx5300 Paperless Data Logger Blue Screen 1-16 Channels Ethernet Function Pressure Temperature and Humidity8792byte
Aof2000 Series Output One-in-One-out Signal Isolator (Resistance Type: Input Impedance > 5KΩ)1579byte
USB Temperature Data Logger Fresh Tag 1u3576byte

CNC Lathe Machines Generator for Automated Systems Printing Machinery High-Quality Factory Direct2706byte
Spot Supply Kt600 Data Logger Paperless Recorder Universal Input 1-16 Channels RS232 Pressure Temperature Humidity3472byte
Bluetag Th30 Wireless Sensor Bluetooth Temperature Humidity Data Logger with External Probe4501byte
Factory Price Kt800 Paperless Data Logger Universal Input 1-48 Channels RS485 Pressure Temperature Humidity with CE Certification3370byte
Smart Digital Wireless Bluetooth Temperature Humidity Sensor with External Probe5969byte

Factory Price Universal Input Data Logger Paperless Recorder with 1-16 Channels for Pressure Temperature Humidity Pg6067byte
Single Use USB Temperature Data Logger for Cold Chain Transportation2070byte
High Precision Wholesale Temperature Sensor and Hygrometer Data Logger3486byte
Temperature and Humidity Mini Data Logger with Long Life Humidity Sensor for Reliable5220byte
IEC En 61000-4-2 Electrostatic Discharge ESD Generator2114byte

BSG921 RF Signal Generator Frequency Range 9kHz~2.1GHz240byte
Industrial Temperature Humidity RS232 Kt800 Paperless Recorder Data Logger Totalizer Datalogger with CE3460byte
Coeus-WiFi Wireless Temperature Humidity Monitor with LCD Display2828byte
EMC IEC 61000-4-4 Electrical Fast Transient Burst Simulator1354byte
HSA800 Series HSA830 Handheld Spectrum Analyzer Frequency Range 9kHz~3.6GHz507byte

High Quality Temperature Humidity Ethernet Kt800 Paperless Recorder Data Logger Totalizer Datalogger with CE3460byte
Genuine New MW-Tektronix Tbs1000c Tbs1052c Digital Storage Oscilloscope 50 MHz 2 Analog Channels Factory Wholesale Price3113byte
Tfg3836 3.6GHz RF Signal Generator3536byte
Atlas Log-TH Temperature Humidity USB Data Logger for Hospital5634byte
Cold Chain Temp Monitor Single Use Pdf USB Data Logger3688byte

GSM SMS Alarm 4G Real Time Temperature Humidity Data Logger2672byte
Edux1052A Oscilloscope: 50 MHz, 2 Analog Channels836byte
Manufacturer Supply Master Gauge Pressure Calibrator2236byte
Communiction Lines 10/700 Lightning Surge Simulator1872byte
BSA921 Spectrum Analyzer Frequency Range 9kHz to 2.1GHz Signal Analyzer153byte

Byd/E-A1 48*48*100mm Temperature Display Controller1156byte
Portable Energy Meter Calibrator for Three-phase Energy Meter Field Test Tunkia TD45504423byte
Lk-Bl2210f High Voltage 220V 1000W 1500W Brushless Motor Driver Controller 10A High Power BLDC Controller 220V3178byte
Portable Single Phase Watt Meter Calibrator2364byte
4 Channel 100MHz 1gsa/S Oszilloskop Digital Storage Speicher Oscilloscope4310byte

Flow Accumulation Liquid Crystal Display Automatic Alarm Flow Integrator1946byte
Advanced Industrial Water Analyzer with Cutting-Edge Quality Sensors1730byte
Temperature and Humidity Data Logger for Gsp Pharmaceutical Warehouse3730byte
Glass pH Sensor pH Electrode pH Probe2385byte
Professional Customized Electronic Control Box with En ASME Stamping Welding Polishing5002byte

Uxr0594bp Infiniium Uxr-Series Oscilloscope: 59 GHz, 4 Channels, 1mm Inputs1865byte
Keysight Desktop Digital Storage Oscilloscope (DSO) Lnfiniium Exr-Series Oscilloscope for Phase Measurements1947byte
1Hz~60kHz 30, 100, 300, 1K, Linear (-3dB ± 1dB) Vibrometer2610byte
Engine-Room Monitoring and Alarming System Vim6-a1492byte
Distribution Transformer Differential Relaying High Accuracy Three-Phase Current Injection Set5091byte

ESD Gun 30kv for Automotive Test3504byte
EMC Immunity IEC/En61000-4-5 Lightning Surge Simualtor1335byte
155c 660c Portable Precision Dry Block Temperature Calibrator Without Measurement3571byte
4-20mA I/P Converter China Manufacturer962byte
Handheld Pneumatic Pressure Calibration Tool - Professional-Standard Pressure Gauge Calibrator3508byte

12kv Tan Delta Tester Transformer Td Detector for Sale4161byte
Portable Digital PT CT Vt 3 Phase Transformer Winding TTR Tester Turn Ratio Meter2847byte
Dual-Channel Arbitrary Function Signal Generator Uni-T UTG2000X with 4.3inch TFT LCD Capacitive Touchscreen for High-Speed Digital Testing6394byte
Fruit Logistics Temperature Monitoring USB Disposable Temperature Data Logger4479byte
Yunyi Ky Series China 16kg Pressure Gauge Calibrator Dead Weight2374byte

CE Certificate Sealing Test Machine Air Tightness Leakage Testing Instrument3874byte
Advanced Pulse Limiter with Wide Frequency Range 50kHz-1GHz PLA030345byte
China Manufacture Single-Use USB Temperature Datalogger Cold Chain Warehouse2440byte
200MHz~ 400MHz 1.2gsa/S 32mpts Tfg2900A Series Dds Signal Generator with Touch Screen2210byte
Ypl-10 IP67 Waterproof High Temperature Measurement Data Logger2224byte

DEC-9303 Shree-Phase Energy Meter Testing Bench2143byte
Reliable FST500-602A Multifunctional Color Paperless Recorder for Industrial Applications1482byte
Temperature Data Logger with Keelin-Beacon APP for Food Safety3472byte
Lp7516 RS232 Bluetooth Enabled Plastic Floor Scales Weighing Indicator1265byte
USB Infrared Thermal Imager Mobile Phone 256*192 Resolution Type-C with Adapter Support Android Smartphone Thermal Camera2160byte

Suspended Solid Sensor for Water Quality Ss Sensor with Self-Cleaning Brush894byte
Touch Screen Air Quality Detector CO2 Pm2.5/10 Hcho Tvoc Temperature Humidity Aqi Meter Monitor6884byte
Marine or Shipboard Gas Instrument Continues Emission Monitoring System Detector2697byte
High Accuracy To1112D Touch Screen Digital Oscilloscope 2 Channels 110MHz Hanheld Osciloscopio Signal Source Multimeter5562byte
3mm 3.2mm Float Tempered Glass for Electronics Devices2871byte

3nh Handheld Colorimeter Nr110 Widely Used in Food Chemical Industry5310byte
100kv Transformer Oil Bdv Tester Xhyy102/100 Insulating Oil Dielectric Strength Tester2079byte
Galvanic 4-20mA/0-20mA Isolator IC for Analog Signal1402byte
Waterproof Camera Inspection Camera with 8mm Camera, 2-Way Tip Articulations, Maximum Angle 210° , 4.3 Inch Monitor1346byte
Digital Display Controller LCD Electronic Controller3438byte

16 Channel Universal Input Color Paperless Screen Recorder2052byte
Ppm-Tc1CT Intelligent Digital Indicator for Temperature, Pressure, Flow and Level Control2436byte
Xiyuan Iepe Transmitter Transducer Signal Conditioner Constant Current Source Conditioner Sensor (XY8201/XY8204/XY8216)3583byte
Advanced Dual Channel Microwave Testing Subsystem with 33dBm Output2157byte
Three Phase Multifunction Reference Standard Meter Hc3100A1441byte

Thermometers for Casting and Smelting High Frequency Melting Furnaces4817byte
Kdzd Second Current Injection Test Set Single Phase Relay Protection Tester1032byte
Hzjb-421 Three Phase Automatic Protection Relay Test Set System/Tester2772byte
Accurate Contact Angle Measurement-Contact Angle Meter-Contact Angle Measuring Instrument4510byte
Lefoo Split Type Digital Modbus Temperature and Humidity Sensor Air Temperature Humidity Transmitter 4-20mA with Display1719byte






Purchasing Agent


Note: Send your message to supplier or manufacturer.

Welcome to our Professional and comprehensive procurement services...

Message:

OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.

Post a Sourcing Request Now »

  • Professiona Secured Trading Service
  • Verified Business Licenses to Supplier or Manufacturer
  • Welcome to our Global alliance Member