CIPDB › China Industry › Metallurgy, Mineral & Energy › Metallurgy Machinery
Entire Fibre Energy Conservation Cabinet Resistance Furnace1
Metallurgy MachineryCabinet Resistance FurnaceFurnace
Shanghai AXD Heavy Machinery Co., Ltd.
Preview:
Product Description Entire Fibre Energy Conservation Cabinet Resistance Furnace1. The heating element is resistance wire, whose Max. Operation temperature is 1000 or 1200.2. The heating-up time from the room temperature to the Max. Operation temperature is no more than 60mins or 80mins, the precision of temperature control is more than ± 2.3. The volume of hearth is between 2_16L.4. The excellent ceramic textile fiber inner line and suitable furnace structure, is able to reduced the consumption of power greatly, The precision of temperature control is only 60% to the conventional furnace, and the consumption of power is only 50_60% to no-load furnace.5. More humanistic moving door with rail, Beautiful and durable Stainless steel shell.6. The controller is equipped with SCR/PID to set the heating rate, which makes it possible for the consistency and repeating of any experiment, interface RS 485 help the customers to control the furnace and record the date in long distance. Induction furnace is used for smelting or insulating ferrous metals, non-ferrous metals, sponge iron, such as scrap iron, scrap steel, copper, aluminum and so on. Complete working equipment such as continuous casting machine, rolling mill, mainly used for the production of billet, steel bar, angle steel, H-beam, I-beam, etc. Using KGPS, IGBT, single or double power supply technology, PLC (Siemens) can be realized throughout the monitoring. Main supply list: 2 sets of electric furnace body, 2 sets of hydraulic or mechanical tilting electric furnace mechanism, 1 set of control platform, 1 set of intermediate frequency control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), low voltage control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), 1 set of capacitor cabinet, 4 or 8 water-cooled cables; 1 water temperature alarm, 1 leakage alarm; 1 crucible mold, 1 liquid One batch of pressure steel pipe, one set of copper row, three water tanks. Transformer, cooling tower, furnace builder, furnace lining ejector, furnace cover.KGSP Induction Electric FurnaceGW-8-4000-0.5J KGSP Induction Electric FurnaceGW-1-750-1JJ Medium frequency coreless electric furnaceGW-50-22000-0.2J No induction melting furnaceGW-0.25-160-1JJ melting electric furnaceGW-1.5-1000-1J Medium frequency induction furnace NO.Electric Furnace TypeInput power(KW)input voltage(V)Input current(A)Rated power(KW)DC current(A)DC voltage(V)Melting rate(T/H)working frequency(HZ)working voltage(V)cooling water pressure(MPA)Rated capacity(T)Power consumption(KWH/T)Power SupplyFurnace body1GW-0.25-160/1JJ180380(6 Pulse)2561603205000.2410007500.1~0.150.25~0.30.257902GW-0.5-250/1JJ280380(6 Pulse)4002505005000.4100015000.1~0.150.25~0.30.57703GW-0.5-250/1J280380(6 Pulse)4002505005000.4100015000.1~0.150.25~0.30.57704GW-0.75-400/1JJ400380(6 Pulse)6504008005000.6100015000.1~0.150.25~0.30.757705GW-0.75-400/1J400380(6 Pulse)6504008005000.6100015000.1~0.150.25~0.30.757706GW-1-500/1JJ550380(6 Pulse)80050010005000.8100015000.1~0.150.25~0.317507GW-1-750/1JJ800380/690(6 Pulse)1200/7007501500/850500/8800.91000/5001500/26000.1~0.150.25~0.31720/6608GW-1-750/1J800380/690(6 Pulse)1200/7007501500/850500/8800.91000/5001500/26000.1~0.150.25~0.31720/6609GW-1.5-1000/0.5JJ1100690(6 Pulse)912100011408801.250026000.1~0.150.25~0.31.570010GW-1.5-1000/0.5J1100690(6 Pulse)912100011408801.250026000.1~0.150.25~0.31.570011GW-2-1500/0.5JJ1650690(6 Pulse)1360150017008801.750026000.1~0.150.25~0.3267512GW-2-1500/0.5J1650690(6 Pulse)1360150017008801.750026000.1~0.150.25~0.3267513GW-2-2000/0.5JJ2200690(6 Pulse)1400200022758801.950026000.1~0.150.25~0.3265014GW-3-2500/0.5JJ2750690/950(6 Pulse)2275/170025002840/2080880/12502.565002600/32000.1~0.150.25~0.33610/56015GW-3-2500/0.5J2750690/950(6 Pulse)2275/170025002840/2080880/12502.565002600/32000.1~0.150.25~0.33610/56016GW-4-3000/0.5J3300690/950(6 Pulse)2730/204030003410/2500880/12503.25002600/32000.1~0.150.25~0.34610/56017GW-5-4000/0.5J4400950(6 Pulse)2300400033301250550034000.1~0.150.25~0.35600/55018GW-6-4000/0.5J4400950(12 Pulse)2300400033301250550034000.1~0.150.25~0.36600/55019GW-8-5000/0.5J5000950(12 Pulse)34005000420012507~850034000.1~0.150.25~0.38600/55020GW-10-6000/0.5J6300950(12 Pulse)37506000460012508.5~950034000.1~0.150.25~0.310600/55021GW-12-8000/0.25J8000950(12 Pulse)49008000600012509~10.525034000.1~0.150.25~0.312600-55022GW-15-8000/0.25J8000950(12 Pulse)49008000600012509~10.525034000.1~0.150.25~0.315600-55023GW-15-10000/0.25J10000950(24 Pulse)6500100008000125013~1525034000.1~0.150.25~0.315600-55024GW-18-12000/0.25J12000950(24 Pulse)81601200010000120015~1725034000.1~0.150.25~0.318600-55025GW-20-12000/0.25J12000950(24 Pulse)81601200010000120017~1925034000.1~0.150.25~0.320600-55026GW-25-14000/0.25J14000950(24 Pulse)94601400011600120019~21150~20034000.1~0.150.25~0.325600-55027GW-30-16000/0.2J16000950(24 Pulse)108501600013300120021~23150~20034000.1~0.150.25~0.330600-55028GW-40-20000/0.2J20000950(24 Pulse)135452000016600120025~27150~20034000.1~0.150.25~0.340600-55029GW-50-22000/0.2J22000950(24 Pulse)149322200018300120025~28150~20034000.1~0.150.25~0.350600-550Note:(1) GW - means medium frequency induction furnace, - 1 - means induction furnace capacity of 1 ton, - 500 - means furnace rated power of 500 KW, / 1 - means furnace operating frequency of 1000 Hz, / 0.5 - means melting furnace frequency of 500 Hz, - J - means hydraulic tilting furnace (furnace shell is steel shell), - JJ - means mechanical tilting furnace. (the shell of the furnace is aluminum alloy).(2) The above quoted price is for routine configuration. Other configurations can be added, such as leak alarm, water temperature alarm, furnace switch, cover mechanism, lining ejector and transformer, cooling device (open and close cooling tower, closed cooling tower, plate heat exchanger)3) If necessary, send technicians to carry out the commissioning: the domestic section is free; the overseas section travel expenses, accommodation and food are borne by the user and each person is subsidized 150 US dollars per day.4) I quote EX-W at a price including simple packing, including shipping charges to Shanghai port area and all inland charges in China.V) The above electric furnace voltage levels are 380V, 690V and 950/1000V, and the frequency is 50HZ. If the user equipment requirements are different from the above voltage levels and frequencies, each item needs to be increased by 15000USD.
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...