IPDB › China Industry › Instruments & Meters › Analysis Instrument
Automatic Oxygen Bomb Calorimeter for Bomb Calorimeter Test for Calorific Value of a Material1
Analysis Instrument, Oxygen Bomb Calorimeter, Calorimeter
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Preview:
Product Description Automatic Oxygen Bomb Calorimeter for Bomb Calorimeter Test for Calorific Value of a MaterialIntroduction:The Automatic Oxygen Bomb Calorimeter is designed and made as per the National Standard of People's Republic of China GB/T213-2008 and ASTM D240 Test Method for Calorific Value of coal, GB/T384-1988 Test Method for Calorific Value of Petroleum Products and Calibration Regulation of People's Republic of China JJG672-2001 Oxygen Bomb Calorimeter, as well as Shanghai enterprise standard Q/YXYY 10 GDY Series Oxygen Bomb Calorimeter.Features:1. The bomb calorimeter adopts semiconductor refrigeration to decide the refrigerating capacity according to the calorific value, the instrument can automatically adjust water temperature and keep water in a relative constant temperature range, realize the continuously and long time test requirement, and make sure the test result is correct.2. The bomb calorimeter adopts USB port,convenient to connect. One computer can control many sets of Oxygen Bomb Calorimeter.3. With a electronic measuring cup itself, no need to weigh the water by manual, it can measure the water volume automatically, the repetitive error<0.4g4. Automatically detecting the resistance of ignition filament, automatically checking the installing condition of ignition filament before test.5. Standard pipeline design, vastly shortening the pipeline,and more reasonable pipeline design to ensure more precision of test results.6. Adopting professional discharge water ports,more convenient and fast when the instrument drains away water or change the water.7. The electronic balance with communication function to share the data by the internet.Specifications:1Measuring temperature range5oC~40oC 2Temperature resolution0.0001oC3RSD(Relative standard deviation)≤0.1% 4Test period≤13mins 5Measuring range 5MJ/kg~40MJ/kg6AccuracyBetter than GB/T213-2008 The determination method of coal calorific value 7Pressure endurance of oxygen bomb20 MPa 8Relative humidity≤85%9Power supplyAC 220V±10V, 50 Hz 10Total power consumption≤0.2kW 11Outline dimension540mm*420mm*420mm12Net weight55kg Picture of Automatic Oxygen Bomb Calorimeter:
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.