Emission Gas Analyzer Cems for Nox So2 Co O22
Analysis Instrument, Emission Gas Analyzer, Cems
Nanjing KELISAIKE Safety Equipment Co., Ltd.
Preview:
Product DescriptionEmission gas analyzer CEMS for Nox SO2 CO O2The analyzer based on UV absorption spectroscopy and chemometric algorithms to measure SO2, NOx, O2, NH3, Cl2, O3, H2S and other gases concentration, with high accuracy, high reliability, fast response time, wide application and other characteristics, the indicators have reached or exceeded similar products, it can be widely used in environmental online monitoring, industrial control, security monitoring and other occasions.SpecificationApplicationsA continuous emission monitoring system (CEMS) is a device used to continuously and in real time monitor the concentration of pollutants in flue gas generated during industrial production. It is widely used in high-pollution industries such as power generation, steel, chemicals, cement, and waste incineration to ensure that pollutant emissions meet national and local environmental standards.Key ConfigurationsFull spectrum measurement and DOAS (Differential Optical Absorption Spectroscopy) algorithm, excelling in accuracy, repeatability and anti-interference with moisture, dust.Modular design and no moving parts, higher reliability and easier maintenance.Pulse Xenon Lamp used as light source with over 10-year lifetime.The adoption of diode array sensor enables instant spectrum acquisition and rapid response.Features and Benefits1. Analyzer uses the following optical technology platform to get the UV absorption spectrum, the technology platform consists of light source, gas chamber, fiber optics and spectroscopy (including the diaphragm, holographic gratings, linear array detector) and other optical components.2. UV-visible light emitted by the optical window into the gas chamber, is absorbed by the sample gas flowing through the measured gas chamber, carrying the tested sample gas absorbs light through the lens after gathering information coupled into optical fiber through the optical fiber transmission into the spectrometer splitting, sampling, to obtain the absorption spectrum of the gas.3. Use DOAS technology spectrum analysis, can analyze the concentration of the gas in the relevant component.Measuring principle1) The light source emits ultraviolet beam which transfers to gas cell through optical fiber.2) After absorption by measuring gas, the light beam transfers through optical fiber to spectrometer.3) Being dispersed through the grating, and converted into electric signal by the array sensor, a continuous absorption spectrum of measuring gas is thereafter obtained.Technical Specifications(Custom configurations available upon request.)ItemUV Hot-Wet MethodNDIRSpectral RangeComplete and continuous absorption spectra obtained through holographic grating and diode array detectionNon Dispersive, characteristic absorption spectra obtained through band-pass filterLinear ResponseHigh wavelength resolution secures linear responseband-pass filtration compromises linear responseSO2 LossHot-wet prohibits SO2 dissolutionCondensation inevitably causes SO2 lossSampling SystemHeat tracing. Requests only dust filtration, simple and no corrosiveCold-dry. Requests dust filtration, condensation, water removal and corrosion proofZero Calibration PeriodLong (DOAS algorithm)ShortAnti-InterferenceThe combination of complete & continuous absorption spectra, high wavelength resolution, DAOS algorithm erases interference from dust, moisture and background gasesVulnerable to moisture interferenceGas CellConnected by optical fiber, easy to replace and low maintenance costComplex to replace and maintenanceMaintenanceReliabilityNo moving partsMoving parts existedTechnical Data for UV gas analyzer Customize producta are also available,pls feel free to contact me for more detailes. ProjectIndicatorsSO2 Detection rangeMin:0-50ppm,Max:0-100%,NO Detection rangeMin:0-50ppm,Max:0-100%,O2 Detection range0-25%, Electrochemical or zirconiaLinearity error≤±1%F.S.Repeatability≤1%Zero drift≤±1%F.S./ weekSpan drift≤±1%F.S./ weekAmbient temperature5oC~45oCResponse time(T90)<60sSize19" *3U*320mmAnalog interface3-way 4-20mA output,2-way 4-20mA outputData interface4-way switch input; 8-way relay outputCommunication Interface1-way RS-232,1-way RS-485(Supports Mod-bus protocol)Power220VAC/50Hz 100WProtection gradeIP42Sample gas input and output interface?6 Tube FittingsAfter Sales ServiceStandard Warranty: 12 months or 2,000 operating hours (whichever comes first).Extended Warranty: Optional coverage up to 36 months.Training: On-site or remote operation/maintenance training.Company ProfileNanjing KELISAIKE Safety Equipment Co., Ltd.Nanjing KELISAIKE company is one of the largest safety equipment manufactures, possesing the most complete production range and specifications in the safety equipment industry of mainland China. Nanjing KELISAIKE was founded in 2004, including three subsidiaries in Beijing, Xi'an and Xinjiang, and more than 30 domestic sales service centers, with total registered capital of 5.16 million Yuan.We are the leader enterprise of the science and technology, persisting in creating core competencies by the core technology. In the company, there is one professional and technical talent team who masters core technology, including more than 10 senior technicans and masters.Standard products and services cover the portable gas detector, fixed gas transmitter, wall-mounted gas detector, gas detector control unit, air breathing apparatus etc. Also Nanjing KELISAIKE is an experienced factory for OEM service, providing professional design and construction of the customize products. The products are widely used in fields of petroleum, chemical, gas transmission and distribution, warehousing, municipal gas, fire fighting, environmental protection, metallurgy, pharmacy, energy and power industry.Why Choose Us?Other ProductsOEM/ODM capabilitiesCompetitive pricing & bulk discountsFast shipping & customs clearance supportTurnkey project solutionsGas leak detectorsInline TDLAS Laser analyzerNDIR ANALYSISParticulate Monitoring FAQQ: What's the lead time for orders?A: Standard models ship in 15–30 days; customized units require 30–45 days.Q: Do you provide after-sales service overseas?A: Yes, we have partners in key regions.Q: Can I request a customized bucket size?A: Absolutely! We offer OEM ODM sevices.Q: What documents do you provide for export?A: Full export package (Commercial Invoice, Packing List, Bill of Lading, COC, etc.).Q: How do I place an order?A: Contact us via email/phone for a quote, then confirm with a PO.
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.