IPDB › China Industry › Instruments & Meters › Analysis Instrument
China Macylab Standard Oil Testing Inductively Coupled Plasma Optical Emission Spectrometer1
Analysis Instrument, Element Analyzer, High Quality Spectrometer, Inductively Coupled Plasma Spectrophotometer
Macylab Instruments Inc.
Preview:
Product Description Product description, technical parameters and configurationICP-6800 Inductively Coupled Plasma Optical Emission Spectrometer(standard)Application fieldsInductively coupled plasma emission spectrometer(ICP6800) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation.At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.Application EnvironmentCONTENT RANGE 19932323279Shipping/Storage Ambient Temperature 15oC-25oCShipping/Storage Relative Humidity ≤70%Atmospheric pressure 86-106 kPaPower Supply 220±10V 50-60MHzWorking Humidity ≤70%Working Temperature 15oC-30oC Technical parametersCircuit type: solid-state RF power supply, with function of automatchFrequency: 27.12MHz±0.05%Frequency Stability: <0.1%Power Output: 800W-1200WPower Output Stability: <0.3%Escaped RF radiation: 30cm away from the instrument, electric field: E<2V/m Sampling System Technical Parameter:Output working coil inner diameter :25mmTorque tube: Three concentric, external diameter 20mmCoaxial nebulizer:Outer diameter 6mmDouble barrel atomizing chamber: Outer diameter 34mm Gas Flow Controls1. Plasma Argon Flowmeter:(100-1000)L/h (1.6-16L/min)2. Auxiliary Argon Flowmeter:(10-100)L/h (0.16-1.66L/min)3. Carrier Argon Flowmeter(10-100)L/h (0.16-1.66L/min)4.Pressure Maintaining Valve(0-0.4MPa)5.Cooling Water:Temperature: 20-25oC, Rate of Flow>5L/min, Hydraulic Pressure>0.1MPa SpectrometerOptics:Czerny-Turner typeFocal length: 1000 mmGrating: Ion Beam Etching Holographic Grating, 3600L/mm or 2400L/mmReciprocal linear dispersion: 0.26nm/mmResolution:≤ 0.007nm (3600 line grating);≤0.015nm (2400line grating)Wavelength range: 3600 line grating:(190nm~500) nm;2400 line grating: (190nm~800) nmMinimum pace of stepping motor: ≤0.0006 nmExit Slit:12μm;Entrance Slit:10μm Photoelectric Converter PerformancePhotomultiplier tube specification: R293/R928Negative HV on PMT: 0-1000V;Stability: <0.05% Overall PerformanceWavelength range of scanning: 195nm~500nm(3600L/mm line grating);195nm~800nm(2400L/mm line grating)Repeatability: RSD(Relative Standard Deviation)≤1.5%Stability: RSD(Relative Standard Deviation) ≤2%Detection Limits (μg/L): ElementWL(nm)Limit ElementWL(nm)LimitLa408.672 <3.0 Cr 267.716 <5.0 Ce413.765 <5.0 Al 396.152 <5.0 Pr414.311 <5.0 Zr 343.823 <5.0 Nd401.225 <5.0 Ag 328.068 <3.0 Sm360.946 <10.0 Sr 407.771 <1.0 Eu381.967 <1.0 Au 242.795 <5.0 Gd342.247 <10.0 Pt 265.945 <5.0Tb350.917 <3.0 Pd 340.458 <5.0 Dy353.170 <3.0 Ir 224.268 <10.0 Ho345.600 <3.0 Rh 343.489 <10.0 Er337.271 <3.0 Ru 240.272 <5.0 Tm313.126 <3.0 Ba 455.403 <1.0 Yb369.419 <1.0 As 228.812 ≤15 Lu261.541 <3.0 Sb 206.833 ≤15 Y371.030 <1.0 Bi 223.061 ≤10 Sc335.373 <1.0 Hg 253.652 ≤15 Ta226.230 <5.0 Pb 220.353 ≤15 Nb313.340 <5.0 Ga 294.364 ≤10 Mn257.610 <3.0 Se 203.985 ≤10Mg279.553 <1.0 Sn 242.949 ≤20 B249.773 <10.0 Te 214.281 ≤10 Zn213.856 <3.0 Ta 226.230 ≤5.0 Co228.616 <3.0 Th 283.730 ≤10 Si251.611 <10.0 Tl 276.787 ≤30 Ni232.003 <5.0 Re 227.525 ≤5 Cd226.502 <3.0 Ge 209.426 ≤15Fe239.562 <3.0 Os 225.585 ≤1 Ca393.366 <1.0 W 207.911 ≤10 Mo281.615 <5.0 Cu324.754 <3.0V310.230 <5.0 Li 670.784 ≤3 Be313.041 <1.0 Na 588.995 ≤20 Ti334.941 <3.0 K766.490≤60 Our AdvantagesPrecision analysis The middle step grating prism cross dispersion mode is adopted, there is no moving optical element, the ultra low stray light design is combined with the unique optical design, nitrogen distributed blowing, imported optical elements, intelligent and accurate automatic wavelength calibration algorithm.Quick test In American thermoelectric CID detector, the 160-1000nm range is continuously covered, and the intensity integral values of all analytical spectral lines are read out at one exposure to speed up the analysis.Technical parameters of the instrumentOutput power: 800 -1500WTotal argon consumption:≤14L/minWavelength range:160nm - 1000 nmResolution: < 0.0065nm@200nmInstrument technical indexMethod of observation: vertical observationLiquid content:0.01ppm~thousands of ppm.Solid content:0.001%~70%Repeatability: RSD < 1%Stability: RSD <1.5%(within 2 hours)Element detection limit (μg/L): most elements 1ppb~10ppbApplication area Silicon industry, metallurgical industry, water quality analysis, geology, ore analysis, petrochemical, medical, sanitary, agricultural environmental protection, commodity, food quality inspection..Certificate
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.